The DOI matches its Crossref record.
Comparison of Viscoelastic Measures of Coagulation after Cardiopulmonary Bypass
Abstract
Postoperative hemorrhage remains a major cause of morbidity after cardiopulmonary bypass (CPB). Treatment remains empiric because of the need for immediate correction and the lack of availability of rapid intraoperative coagulation monitoring (except for ACT) at most institutions. Thrombelastography (TEG) and Sonoclot analysis (SCT) are measures of viscoelastic properties of blood which allow rapid intraoperative evaluation of coagulation factor and platelet activity as well as overall clot integrity from a single blood sample. Routine coagulation tests (RCT) including activated clotting time (ACT), prothrombin time (PT), partial thromboplastin time (PTT), fibrinogen level (FIB), and platelet count (PLT) were determined and compared to TEG and SCT to assess which best predicted clinical hemostasis after CPB. Forty-two patients prospectively felt to be at high risk for excessive post-CPB bleeding had blood obtained for RCT, TEG, and SCT analysis before systemic heparinization and 30 min after protamine administration. Nine of 42 patients had excessive chest tube drainage, but no reoperations were required. After CPB, mean values for RCT were normal, but there were abnormalities in TEG and SCT parameters that reflect platelet-fibrin interaction. Both TEG and SCT were 100% accurate in predicting bleeding in these nine patients and, overall, both tests were significantly better predictors of postoperative hemorrhage than RCT. We conclude that viscoelastic determinants of clot strength may be abnormal after CPB and that SCT and TEG are, therefore, more useful than RCT for the detection and management of coagulation defects associated with CPB.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Thromboelastography-Guided Transfusion Algorithm Reduces Transfusions in Complex Cardiac Surgery
Shore-Lesserson, L., Manspeizer, H. E., DePerio, M., Francis, S., Vela-Cantos, F., & Ergin, M. A. (1999) · Anesthesia & Analgesia · doi:10.1097/00000539-199902000-00016 · Cited by 845
Ganter, M. T., & Hofer, C. K. (2008) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318168b367 · Cited by 677
Whiting, P., Al, M., Westwood, M., Ramos, I. C., Ryder, S., Armstrong, N., Misso, K., Ross, J., Severens, J., & Kleijnen, J. (2015) · Health Technology Assessment · doi:10.3310/hta19580 · Cited by 310
Salooja, N., & Perry, D. J. (2001) · Blood Coagulation and Fibrinolysis · doi:10.1097/00001721-200107000-00001 · Cited by 266
Thrombelastography and tromboelastometry in assessing coagulopathy in trauma
Johansson, P. I., Stissing, T., Bochsen, L., & Ostrowski, S. R. (2009) · Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine · doi:10.1186/1757-7241-17-45 · Cited by 255
Metadata
- Authors
- Tuman, K. J., Spiess, B. D., McCarthy, R. J., & Ivankovich, A. D.
- Venue
- Anesthesia & Analgesia
- Published
- 1989-07
- Volume
- 69
- Issue
- 1
- Pages
- 69???75
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2075273329
- Cited by
- 175
- References
- 0
- FWCI
- 3.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Viscoelastic Measures of Coagulation after Cardiopulmonary Bypass. https://app.cochat.ai/papers/10.1213/00000539-198907000-00013
- The paper
- Tuman, K. J., Spiess, B. D., McCarthy, R. J., & Ivankovich, A. D. (1989). Comparison of Viscoelastic Measures of Coagulation after Cardiopulmonary Bypass. Anesthesia & Analgesia. https://doi.org/10.1213/00000539-198907000-00013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.