The DOI matches its Crossref record.
A Proposal to Use Confidence Intervals for Visual Analog Scale Data for Pain Measurement to Determine Clinical Significance
Abstract
Visual analog scales (VAS) ranging from 0 cm (no pain) to 10 cm (worst imaginable pain) are used widely for pain measurement, but various investigators have not treated these data consistently. Conventional statistical tests of such data, although evaluating the "statistical significance" may obscure the clinical value of a treatment. On the other hand, confidence intervals (CIs) can illuminate both statistical and clinical importance. CIs give a range of values based on the observed data which contain, with a specified probability, a true but unknown variable typifying a population. We reviewed 112 articles published recently in anesthesia journals for statistical reporting of VAS data. Of the 112 articles, only two used CIs to report mean pain scores and one used CIs to report differences in median pain scores between the study groups. Only two articles presented 95% CI for the mean pain scores graphically. Analgesic techniques that produce VAS values in the range of 0-3 have been reported to represent adequate analgesia. A graphical method using CIs is proposed that allows ready interpretation of VAS data. With this approach, one evaluates whether the 95% CI for the mean pain score in a group during a particular period lies entirely within the zone defined as "analgesic success" (0-3). Such an analysis allows a visual assessment of whether a particular technique would produce clinically important effects in the population at large. This approach seems to provide more information than the use of conventional hypothesis testing in the interpretation of VAS data for pain measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Pain Visual Analog Scale: Is It Linear or Nonlinear?
Myles, P. S., Troedel, S., Boquest, M., & Reeves, M. (1999) · Anesthesia & Analgesia · doi:10.1213/00000539-199912000-00038 · Cited by 299
Wallace, K. L., Middleton, S., & Cook, I. J. (2000) · Gastroenterology · doi:10.1016/s0016-5085(00)70137-5 · Cited by 269
Kropmans, T. J. B., Dijkstra, P. U., Stegenga, B., Stewart, R., & de Bont, L. G. M. (1999) · Journal of Dental Research · doi:10.1177/00220345990780031101 · Cited by 126
Metadata
- Authors
- Mantha, S., Thisted, R., Foss, J., Ellis, J. E., & Roizen, M. F.
- Venue
- Anesthesia & Analgesia
- Published
- 1993-11
- Volume
- 77
- Issue
- 5
- Pages
- 1041???1047
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2060954977
- Cited by
- 168
- References
- 0
- FWCI
- 7.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Proposal to Use Confidence Intervals for Visual Analog Scale Data for Pain Measurement to Determine Clinical Significance. https://app.cochat.ai/papers/10.1213/00000539-199311000-00029
- The paper
- Mantha, S., Thisted, R., Foss, J., Ellis, J. E., & Roizen, M. F. (1993). A Proposal to Use Confidence Intervals for Visual Analog Scale Data for Pain Measurement to Determine Clinical Significance. Anesthesia & Analgesia. https://doi.org/10.1213/00000539-199311000-00029
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.