CoChat

Comparison of Potency and Duration of Action of Nalmefene and Naloxone

Glass, Peter S. A., Jhaveri, Rajiv M., Smith, L. Richard · 1994 · Anesthesia & Analgesia
Cited by 94

The DOI matches its Crossref record.

Abstract

Nalmefene, a pure opiate antagonist structurally similar to naloxone, possesses a longer duration of action than naloxone at the same dose. However, the relative potency of these two antagonists is not known. This study was, therefore, designed to establish their potency ratio and duration of action at equipotent doses. Sixteen healthy, adult volunteers were allocated to one of four groups of four subjects each. A continuous fen-tanyl infusion was started to obtain a target plasma concentration of 1.5 ng/mL. The extent of respiratory depression was evaluated at 20 min (first depression) by recording end-tidal CO2 (ETCO2), respiratory rate (RR), arterial oxygen saturation (Spo2), arterial blood gases, and ventilatory response to a hypercapnic challenge. Consecutive groups then received 1, 2, 4, and 8 μg/kg of naloxone and nalmefene, in a double-blind, cross-over fashion, on separate occasions. Fentanyl infusion was continued and ETco2, Spo2, and RR were recorded every 5 min until the values obtained at the first depression were reestablished (second depression). Multiple blood samples for plasma levels of the test drug and fentanyl were taken. Ventilatory function was assessed at baseline, first depression, 5 min after test drug administration, and at second depression. The ventilatory variables were compared using analysis of variance (ANOVA). There was a significant improvement in the slope and intercept of the Co2 response curve produced by the increasing doses (P < 0.05). There was no difference in recovery of these variables between the two drugs at the same dose, implying that the doses were equipotent. The mean plasma concentrations of nalmefene and naloxone at which ventilatory depression recurred were 0.3 ± 0.08 ng/mL and 0.28 ± 0.05 ng/mL, respectively (P > 0.05). The duration of action of nalmefene was longer than naloxone over the dose range studied (P < 0.01). The initial volume of distribution (V1) for naloxone was 0.29 L/kg and its steady-state volume of distribution (Vdss) was 2.64 L/kg. These values were similar to those for nalmefene (V1 = 0.26 L/kg, Vdss = 2.28 L/kg). The clearance of naloxone (0.049 L/min) was more rapid than that of nalmefene (0.019 L/min) and thus, the elimination half-life of naloxone (54.5 min) was significantly shorter than that of nalmefene (108 min) (P < 0.05). We conclude that nalmefene is equipotent to naloxone, both in terms of dose (mg/mg) and plasma concentration; however, due to its slower clearance, its duration of effect is prolonged compared to that of naloxone. (Anesth Analg 1994;78:536–41)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/00000539-199403000-00021

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 94

Metadata

Authors
Glass, P. S. A., Jhaveri, R. M., & Smith, L. R.
Venue
Anesthesia & Analgesia
Published
1994-03
Volume
78
Issue
3
Pages
536???541
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2016982455
Cited by
94
References
0
FWCI
1.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Potency and Duration of Action of Nalmefene and Naloxone. https://app.cochat.ai/papers/10.1213/00000539-199403000-00021
The paper
Glass, P. S. A., Jhaveri, R. M., & Smith, L. R. (1994). Comparison of Potency and Duration of Action of Nalmefene and Naloxone. Anesthesia & Analgesia. https://doi.org/10.1213/00000539-199403000-00021

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.