The Pupillary Effects of Intravenous Morphine, Codeine, and Tramadol in Volunteers
The DOI matches its Crossref record.
Abstract
In Brief Opioid analgesics have pharmacological effects in many organ systems, including the eye. Because the metabolites of morphine and codeine contribute to their overall pharmacological effect pupil diameter measurements were made over a 6-h period. We studied the pupillary effects of IV morphine (0.125 mg/kg), codeine (1 mg/kg), tramadol (1.25 mg/kg), or placebo (10 mL 0.9% w/v sodium chloride) in 10 healthy volunteers. Pupil diameter was measured every 30 min using a pupil densitometer. Comparisons of the change in pupil diameter for each drug were made using analysis of variance with repeated measures. No significant change in pupil diameter was observed after placebo. After IV morphine and codeine administration there was a 26% decrease in pupil diameter (P < 0.001). Over the course of the study period, pupil diameter gradually returned to baseline values. After administration of tramadol there were no significant changes in pupil diameter until 150 min after administration, after which there was a significant reduction for the remainder of the study period (P < 0.01). The changes in pupil diameter may be explained in part by the pharmacokinetic profiles of the opioids studied. Measurement of pupil diameter may have a place in monitoring the central effect of opioids. IMPLICATIONS: The effect of several opioid analgesics on pupillary size has been studied. The results may be explained by differences in metabolism and pharmacokinetics of the drugs used. The data may be of use in defining a marker for the central effect of opioids and when assessing the degree of opioid toxicity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In recent years, pupillometric parameters such as the Pupillary Pain Index (PPI) and constriction velocity/latency have been reported as reliable indicators that assist in ensuring intraoperative and postoperative analgesia and in assessing pain severity (29,37,(49)(50)(51).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [51]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 24
- Murray, 1983, Life Sci, 33, 495, 10.1016/0024-3205(83)90123-6 · DOI
- Miller, 1990, Br J Anaesth, 65, 415, 10.1093/bja/65.3.415 · DOI
- Peacock, 1988, Br J Anaesth, 61, 598, 10.1093/bja/61.5.598 · DOI
- Asbury, 1986, Anaesthesia, 41, 717, 10.1111/j.1365-2044.1986.tb12838.x · doi:10.1111/j.1365-2044.1986.tb12838.x
- Lewis, 1997, Am J Health Syst Pharm, 54, 643, 10.1093/ajhp/54.6.643 · DOI · Paper page
- Lee, 1975, J Pharmacol Exp Ther, 192, 415
- Paul, 1989, J Pharmacol Exp Ther, 251, 477
- Chen, 1991, Life Sci, 48, 2165, 10.1016/0024-3205(91)90150-A · DOI · Paper page
- Oguri, 1987, Life Sci, 41, 1457, 10.1016/0024-3205(87)90710-7 · doi:10.1016/0024-3205(87)90710-7
- Pasternak, 1987, Life Sci, 41, 2845, 10.1016/0024-3205(87)90431-0 · DOI · Paper page
- Frances, 1992, J Pharmacol Exp Ther, 262, 25
- Osborne, 1993, Clin Pharmacol Ther, 54, 158, 10.1038/clpt.1993.127 · DOI · Paper page
- Osborne, 1990, Clin Pharmacol Ther, 47, 12, 10.1038/clpt.1990.2 · DOI · Paper page
- Vree, 1992, Biopharm Drug Dispos, 13, 445, 10.1002/bdd.2510130607 · doi:10.1002/bdd.2510130607
- Mignat, 1995, Life Sci, 56, 793, 10.1016/0024-3205(95)00010-4 · DOI · Paper page
- Vree, 2000, Int J Clin Prac, 54, 395, 10.1111/j.1742-1241.2000.tb11929.x · DOI
- Raffa, 1992, J Pharmacol Exp Ther, 260, 275
- Driessen, 1992, Br J Pharmacol, 105, 147, 10.1111/j.1476-5381.1992.tb14226.x · DOI · Paper page
- Sevcik, 1993, Br J Pharmacol, 110, 169, 10.1111/j.1476-5381.1993.tb13788.x · DOI
- Lotch, 2001, Anesthesiology, 85, 1329, 10.1097/00000542-200112000-00009 · DOI
- Jeffrey, 1999, Br J Anaesth, 83, 245, 10.1093/bja/83.2.245 · doi:10.1093/bja/83.2.245
- Krueger, 1978, Arzneimittel-Forschung, 28, 176
- Onal, 1999, Gen Pharmacol, 33, 83, 10.1016/S0306-3623(98)00256-0 · doi:10.1016/s0306-3623(98)00256-0
- Yue, 1991, Br J Clin Pharmacol, 31, 635, 10.1111/j.1365-2125.1991.tb05585.x · DOI
Cited by
Samuels, E., & Szabadi, E. (2008) · Current Neuropharmacology · doi:10.2174/157015908785777193 · Cited by 454
Pupil and Pupillary Light Reflex
Özdağ, D., & Oztas, B. (2025) · Sakarya Üniversitesi Holistik Sağlık Dergisi · doi:10.54803/sauhsd.1767753 · Cited by 1
Metadata
- Authors
- Knaggs, R. D., Crighton, I. M., Cobby, T. F., Fletcher, A. J. P., & Hobbs, G. J.
- Venue
- Anesthesia & Analgesia
- Published
- 2004-07
- Volume
- 99
- Issue
- 1
- Pages
- 108-112
- ISSN
- 0003-2999
- Cited by
- 64
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.