Reflective forehead pulse oximeter sensors have recently been introduced into clinical practice. They reportedly have the advantage of faster response times and immunity to the effects of vasoconstriction. Of concern are reports of signal instability and erroneously low Spo(2) values with some of these new sensors. During a study of the plethysmographic wave forms from various sites (finger, ear, and forehead) it was noted that in some cases the forehead wave form became unexpectedly complex in configuration. The plethysmographic signals from 25 general anesthetic cases were obtained, which revealed the complex forehead wave form during 5 cases. We hypothesized that the complex wave form was attributable to an underlying venous signal. It was determined that the use of a pressure dressing over the sensor resulted in a return of a normal plethysmographic wave form. Further examination of the complex forehead wave form reveal a morphology consistent with a central venous trace with atrial, cuspidal, and venous waves. It is speculated that the presence of the venous signal is the source of the problems reported with the forehead sensors. It is believed that the venous wave form is a result of the method of attachment rather than the use of reflective plethysmographic sensors.

Integrity signals

Registry

Crossref · 10.1213/01.ane.0000145063.01043.4b

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Pulse oximetry values were both lower in cases where CVP contributed to the signal.

    “The pulse oximetry values were both lower in cases where CVP contributed to the signal.”
  • Shelley et al. and Sami et al. both demonstrated the influence of the venous signal on SpO2, showing that forehead and earlobe pulse oximeters produced a significantly biased variable component of the PPG determined to originate from central venous pressure (CVP).

    “Shelley et al. and Sami et al. both demonstrated the influence of the venous signal on SpO2, showing that forehead and earlobe pulse oximeters (respectively) produced a significantly biased variable component of the PPG determined to originate from central venous pressure (CVP) [125,127].”
  • The difference in compliance between the arterial and venous systems, as well as the lower-pressure gradient, translates to the relative amplitude of the AC venous component of the PPG being smaller than the AC arterial component.

    “The difference in compliance between the arterial and venous systems, as well as the lower-pressure gradient, translates to the relative amplitude of the AC venous component of the PPG being smaller than the AC arterial component [125].”
  • Eliminating venous contributions to PPG by application of contact pressure may eliminate the arterial pulsation in hypotensive patients as well as increase pressure-induced injury risk to the measurement site.

    “However, it is possible that this will eliminate the arterial pulsation in hypotensive patients as well as increase pressure-induced injury risk to the measurement site [125].”

The citation lists haven’t been fetched yet

References 7 · Cited by 91

Authors
Shelley, K. H., Tamai, D., Jablonka, D., Gesquiere, M., Stout, R. G., & Silverman, D. G.
Affiliations
Yale University (US)
Corresponding author
Shelley, Kirk H.
Venue
Anesthesia & Analgesia
Published
2005-03
Volume
100
Issue
3
Pages
743-747
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2035219544
Cited by
91
References
7
Citations by year
2025: 2 · 2024: 4 · 2023: 2 · 2022: 7 · 2021: 9 · 2020: 2 · 2019: 3 · 2018: 5 · 2017: 7 · 2016: 3 · 2015: 5 · 2014: 4 · 2013: 3 · 2012: 3
FWCI
5.43
Type
journal article
Language
en
Open access
closed
Locations
  • Anesthesia & Analgesia (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
Keywords
venous pulsation, central venous pressure, pressure dressing
MeSH terms
Female, Forehead, Humans, Male, Oximetry, Oxygen, Plethysmography, Veins

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review