Estimation of Functional Residual Capacity at the Bedside Using Standard Monitoring Equipment: A Modified Nitrogen Washout/Washin Technique Requiring a Small Change of the Inspired Oxygen Fraction
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In Brief We developed a modified nitrogen washin/washout technique based on standard monitors using inspiratory and end-tidal gas concentration values for functional residual capacity (FRC) measurements in patients with acute respiratory failure (ARF). For validation we used an oxygen-consuming lung model ventilated with an inspiratory oxygen fraction (Fio2) between 0.3 and 1.0. The respiratory quotient of the lung model was varied between 0.7 and 1.0. Measurements were performed changing Fio2 with fractions of 0.1, 0.2, and 0.3. In 28 patients with ARF, duplicate measurements were performed. In the lung model, an Fio2 change of 0.1 resulted in a value of 103 ± 5% of the reference FRC value of the lung model, and the precision was equally good up to an Fio2 of 1.0 with a value of 103 ± 7%. In the patients, duplicate measurements showed a bias of −5 mL with a 95% confidence interval [−38; 29 mL ]. A comparison of a change in Fio2 of 0.1 with 0.3 showed a bias of −9 mL and limits of agreement of [−365; 347 mL]. This study shows good precision of FRC measurements with standard monitors using a change in Fio2 of only 0.1. Measurements can be performed with equal precision up to an Fio2 of 1.0. IMPLICATIONS: Presently there is no clinical method for measuring the functional residual capacity (FRC) in mechanically ventilated patients with acute respiratory failure. We have developed a nitrogen washin/washout method for FRC measurements using standard monitors requiring only a 0.1 change in inspiratory oxygen fraction (Fio2). The method can be used up to an Fio2 of 1.0.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Cited by
Futier, E., Constantin, J.-M., Pelosi, P., Chanques, G., Massone, A., Petit, A., Kwiatkowski, F., Bazin, J.-E., & Jaber, S. (2011) · Anesthesiology · doi:10.1097/aln.0b013e31821811ba · Cited by 212
“1, without interruption of mechanical ventilation or any need for supplementary tracer gases, as described in detail elsewhere.(21,22) In all patients, EELV values were indexed according to predicted body weight, which was calculated for men as 50 0.”
MethodClinical review: Respiratory monitoring in the ICU - a consensus of 16
Brochard, L., Martin, G. S., Blanch, L., Pelosi, P., Belda, F. J., Jubran, A., Gattinoni, L., Mancebo, J., Ranieri, V. M., Richard, J.-C. M., et al. (2012) · Critical Care · doi:10.1186/cc11146 · Cited by 160
“Olegard and colleagues [78] reported that, by changing the FiO2 abruptly by as little as 0.”
BackgroundSelf-citation
Metadata
- Authors
- Oleg??rd, C., S??ndergaard, S., Houltz, E., Lundin, S., & Stenqvist, O.
- Venue
- Anesthesia & Analgesia
- Published
- 2005-07
- Volume
- 101
- Issue
- 1
- Pages
- 206-212
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W1994406765
- Cited by
- 184
- References
- 2
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimation of Functional Residual Capacity at the Bedside Using Standard Monitoring Equipment: A Modified Nitrogen Washout/Washin Technique Requiring a Small Change of the Inspired Oxygen Fraction. https://app.cochat.ai/papers/10.1213/01.ane.0000165823.90368.55
- The paper
- Oleg??rd, C., S??ndergaard, S., Houltz, E., Lundin, S., & Stenqvist, O. (2005). Estimation of Functional Residual Capacity at the Bedside Using Standard Monitoring Equipment: A Modified Nitrogen Washout/Washin Technique Requiring a Small Change of the Inspired Oxygen Fraction. Anesthesia & Analgesia. https://doi.org/10.1213/01.ane.0000165823.90368.55
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.