Monitoring Brain Oxygen Saturation During Coronary Bypass Surgery: A Randomized, Prospective Study
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Cerebral deoxygenation is associated with various adverse systemic outcomes. We hypothesized, by using the brain as an index organ, that interventions to improve cerebral oxygenation would have systemic benefits in cardiac surgical patients. METHODS: Two-hundred coronary artery bypass patients were randomized to either intraoperative cerebral regional oxygen saturation (rSO2) monitoring with active display and treatment intervention protocol (intervention, n = 100), or underwent blinded rSO2 monitoring (control, n = 100). Predefined clinical outcomes were assessed by a blinded observer. RESULTS: Significantly more patients in the control group demonstrated prolonged cerebral desaturation (P = 0.014) and longer duration in the intensive care unit (P = 0.029) versus intervention patients. There was no difference in overall incidence of adverse complications, but significantly more control patients had major organ morbidity or mortality (death, ventilation >48 h, stroke, myocardial infarction, return for re-exploration) versus intervention group patients (P = 0.048). Patients experiencing major organ morbidity or mortality had lower baseline and mean rSO2, more cerebral desaturations and longer lengths of stay in the intensive care unit and postoperative hospitalization, than patients without such complications. There was a significant (r(2) = 0.29) inverse correlation between intraoperative rSO2 and duration of postoperative hospitalization in patients requiring > or =10 days postoperative length of stay. CONCLUSION: Monitoring cerebral rSO2 in coronary artery bypass patients avoids profound cerebral desaturation and is associated with significantly fewer incidences of major organ dysfunction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The society of thoracic surgeons: 30-day operative mortality and morbidity risk models
Shroyer, A. L. W., Coombs, L. P., Peterson, E. D., Eiken, M. C., DeLong, E. R., Chen, A., Ferguson, T. B., Grover, F. L., & Edwards, F. H. (2003) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(03)00179-6 · Cited by 662
Levi, M., Cromheecke, M. E., de Jonge, E., Prins, M. H., de Mol, B. J., Briët, E., & Büller, H. R. (1999) · The Lancet · doi:10.1016/s0140-6736(99)01264-7 · Cited by 545
Casati, A., Fanelli, G. C., Pietropaoli, P., Proietti, R., Tufano, R., Danelli, G. F., Fierro, G., COSMO, G. D., & Servillo, G. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000166974.96219.cd · Cited by 368
Yao, F.-S. F., Tseng, C.-C. A., Ho, C.-Y. A., Levin, S. K., & Illner, P. (2004) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2004.07.007 · Cited by 351
Murkin, J. M., Martzke, J. S., Buchan, A. M., Bentley, C., & Wong, C. J. (1995) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(95)70230-x · Cited by 334
Self-citationBenefit of neurophysiologic monitoring for pediatric cardiac surgery
Austin, E. H., Edmonds, H. L., Auden, S. M., Seremet, V., Niznik, G., Sehic, A., Sowell, M. K., Cheppo, C. D., & Corlett, K. M. (1997) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(97)70074-6 · Cited by 296
Sedrakyan, A., Treasure, T., & Elefteriades, J. A. (2004) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2004.03.041 · Cited by 279
Kim, M. B., Ward, D. S., Cartwright, C. R., Kolano, J., Chlebowski, S., & Henson, L. C. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009940031063 · Cited by 244
Taillefer, M.-C., & Denault, A. Y. (2005) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03018586 · Cited by 154
Noninvasive assessment of cardiac output
Hoffman, G. M., Ghanayem, N. S., & Tweddell, J. S. (2005) · Seminars in Thoracic and Cardiovascular Surgery Pediatric Cardiac Surgery Annual · doi:10.1053/j.pcsu.2005.01.005 · Cited by 125
Cited by
Near-infrared spectroscopy as an index of brain and tissue oxygenation
Murkin, J. M., & Arango, M. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep299 · Cited by 877
Self-citation2011 ACCF/AHA Guideline for Coronary Artery Bypass Graft Surgery
Hillis, L. D., Smith, P. K., Anderson, J. L., Bittl, J. A., Bridges, C. R., Byrne, J. G., Cigarroa, J. E., DiSesa, V. J., Hiratzka, L. F., Hutter, A. M., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.009 · Cited by 820
Writing Committee Members, Hillis, L. D., Smith, P. K., Anderson, J. L., Bittl, J. A., Bridges, C. R., Byrne, J. G., Cigarroa, J. E., DiSesa, V. J., Hiratzka, L. F., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823c074e · Cited by 781
Slater, J. P., Guarino, T., Stack, J., Vinod, K., Bustami, R. T., Brown, J. M., Rodriguez, A. L., Magovern, C. J., Zaubler, T., Freundlich, K., et al. (2009) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2008.08.070 · Cited by 626
Writing Committee Members, Hillis, L. D., Smith, P. K., Anderson, J. L., Bittl, J. A., Bridges, C. R., Byrne, J. G., Cigarroa, J. E., DiSesa, V. J., Hiratzka, L. F., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823b5fee · Cited by 614
Czerny, M., Schmidli, J., Adler, S., van den Berg, J. C., Bertoglio, L., Carrel, T., Chiesa, R., Clough, R. E., Eberle, B., Etz, C., et al. (2019) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezy313 · Cited by 613
The cerebral effects of ascent to high altitudes
Wilson, M. H., Newman, S., & Imray, C. H. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(09)70014-6 · Cited by 525
Scheeren, T. W. L., Schober, P., & Schwarte, L. A. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9348-y · Cited by 478
Davie, S. N., & Grocott, H. P. (2012) · Anesthesiology · doi:10.1097/aln.0b013e31824c00d7 · Cited by 383
Czerny, M., Schmidli, J., Adler, S., van den Berg, J. C., Bertoglio, L., Carrel, T., Chiesa, R., Clough, R. E., Eberle, B., Etz, C., et al. (2019) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2018.09.016 · Cited by 347
Hyttel-Sorensen, S., Pellicer, A., Alderliesten, T., Austin, T., van Bel, F., Benders, M., Claris, O., Dempsey, E., Franz, A. R., Fumagalli, M., et al. (2015) · BMJ · doi:10.1136/bmj.g7635 · Cited by 309
Preoperative Cerebral Oxygen Saturation and Clinical Outcomes in Cardiac Surgery
Heringlake, M., Garbers, C., Käbler, J.-H., Anderson, I., Heinze, H., Schön, J., Berger, K.-U., Dibbelt, L., Sievers, H.-H., & Hanke, T. (2011) · Anesthesiology · doi:10.1097/aln.0b013e3181fef34e · Cited by 303
Zheng, F., Sheinberg, R., Yee, M.-S., Ono, M., Zheng, Y., & Hogue, C. W. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318277a255 · Cited by 299
Cerebral Near-Infrared Spectroscopy in Adults: A Work in Progress
Ghosh, A., Elwell, C., & Smith, M. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31826dd6a6 · Cited by 277
Berger, M., Schenning, K. J., Brown, C. H., Deiner, S. G., Whittington, R. A., & Eckenhoff, R. G. (2018) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000003841 · Cited by 274
Relationship between Hypotension and Cerebral Ischemia during Hemodialysis
MacEwen, C., Sutherland, S., Daly, J., Pugh, C., & Tarassenko, L. (2017) · Journal of the American Society of Nephrology · doi:10.1681/asn.2016060704 · Cited by 189
de Tournay-Jetté, E., Dupuis, G., Bherer, L., Deschamps, A., Cartier, R., & Denault, A. (2011) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2010.03.019 · Cited by 185
Colak, Z., Borojevic, M., Bogovic, A., Ivancan, V., Biocina, B., & Majeric-Kogler, V. (2015) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezu193 · Cited by 183
“Prolonged desaturation was determined as the rSO2 area under the curve (AUC) of more than 150 min% under 20% of baseline value, or rSO2 AUC of more than 50 min% under 50% of absolute value according to data from earlier studies [12, 13].”
MethodRanucci, M., Isgrò, G., Carlucci, C., De La Torre, T., Enginoli, S., Frigiola, A., & Surgical and Clinical Outcome REsearch (SCORE) Group (2010) · Critical Care · doi:10.1186/cc9217 · Cited by 100
Smith, P. J., Blumenthal, J. A., Hoffman, B. M., Rivelli, S. K., Palmer, S. M., Davis, R. D., & Mathew, J. P. (2016) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201507-454oc · Cited by 46
Fellahi, J.-L., Butin, G., Fischer, M.-O., Zamparini, G., Gérard, J.-L., & Hanouz, J.-L. (2013) · Journal of Critical Care · doi:10.1016/j.jcrc.2013.05.004 · Cited by 42
Metadata
- Authors
- Murkin, J. M., Adams, S. J., Novick, R. J., Quantz, M., Bainbridge, D., Iglesias, I., Cleland, A., Schaefer, B., Irwin, B., & Fox, S.
- Venue
- Anesthesia & Analgesia
- Published
- 2007-01
- Volume
- 104
- Issue
- 1
- Pages
- 51-58
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2064113887
- Cited by
- 813
- References
- 17
- FWCI
- 20.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.