Cited by 194Non-Invasive Vital Sign MonitoringOptical Imaging and Spectroscopy TechniquesAnalytical Chemistry and Sensors

The Light–Tissue Interaction of Pulse Oximetry

Mannheimer, Paul D.·2007·Anesthesia & Analgesia

Abstract

The underlying science of pulse oximetry is based on a simple manipulation of the Lambert-Beer law, which describes the attenuation of light traveling through a mixture of absorbers. Signals from detected red and infrared light that has traveled through blood-perfused tissues are used to estimate the underlying arterial hemoglobin oxygen saturation. However, light scatters in tissue and influences some of the simplifications made in determining this relationship. Under most clinical circumstances, the empirical process that manufacturers use to calibrate the system during its design readily accommodates this and results in accurate readings. The same tissue light scattering properties allow sensors to be configured for use on opposing or adjacent surfaces, provided that the placement sites offer sufficient signal strength and are absent factors known to influence accuracy. In this paper I review the light-tissue interaction in pulse oximetry and describe some of the assumptions made and their implications. Certain deviations from the nominal conditions, whether clinical in nature or misuse of the product, can affect system performance. Consequently, users should be cautious in modifying sensors and/or using them on tissue sites not intended by the manufacturer (off-label use). While perhaps helpful for obtaining pulsatile signals or extending the lifetime of a sensor, some practices can disrupt the optical integrity of the measurement and negatively impact the oxygen saturation reading accuracy.

Integrity signals

Registry

Crossref · 10.1213/01.ane.0000269522.84942.54

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 43 · Cited by 194

Authors
Mannheimer, P. D.
Corresponding author
Mannheimer, Paul D.
Venue
Anesthesia & Analgesia
Published
2007-12
Volume
105
Issue
6
Pages
S10-S17
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2018997632
Cited by
194
References
43
Citations by year
2026: 9 · 2025: 14 · 2024: 10 · 2023: 15 · 2022: 13 · 2021: 12 · 2020: 12 · 2019: 13 · 2018: 12 · 2017: 18 · 2016: 15 · 2015: 10 · 2014: 10 · 2013: 9 · 2012: 8
FWCI
0.18
Type
journal article
Language
en
Open access
closed
Locations
  • Anesthesia & Analgesia (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
Keywords
pulse oximetry, light-tissue interaction, light scattering, Beer-Lambert law, arterial oxygen saturation, sensor calibration, sensor placement, measurement accuracy
MeSH terms
Calibration, Equipment Design, Humans, Light, Models, Cardiovascular, Oximetry, Oxygen, Oxyhemoglobins, Scattering, Radiation, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review