Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 176

The DOI matches its Crossref record.

Compliance and Dead Space Fraction Indicate an Optimal Level of Positive End-Expiratory Pressure After Recruitment in Anesthetized Patients

Maisch, Stefan, Reissmann, Hajo, Fuellekrug, Bernd, Weismann, Dieter, Rutkowski, Thomas, Tusman, Gerardo, Bohm, Stephan H. · 2008 · Anesthesia & Analgesia

Abstract

BACKGROUND: "Optimal" positive end-expiratory pressure (PEEP) can be defined as the PEEP that prevents recollapse after a recruitment maneuver, avoids over-distension, and, consequently, leads to optimal lung mechanics at minimal dead space ventilation. In this study, we analyzed the effects of PEEP and recruitment on functional residual capacity (FRC), compliance, arterial oxygen partial pressure (Pao2) and dead space fraction, and we determined the most suitable variables indicating optimal PEEP. METHODS: We studied 20 anesthetized patients with healthy lungs undergoing faciomaxillary surgery. After a stepwise increase of PEEP/inspiratory pressures (0/10, 5/15, 10/20, 15/25 cm H2O, each level lasting for 20 min) using a pressure-controlled ventilation mode, a recruitment maneuver (at 20/45 cm H2O for a maximum of 20 min) was performed, followed by a stepwise pressure reduction (15/25, 10/20, 5/15, 0/10 cm H2O, with 20 min at each level). At each pressure level, FRC, compliance, Pao2, and dead space fraction were measured. RESULTS: When comparing the values before and after recruitment at identical PEEP levels, all variables showed significant changes at 10/20 cm H2O; compliance was also significantly higher at the pressure step 15/25 cm H2O. In addition, FRC values showed significant differences at 5/15 cm H2O and 15/25 cm H2O. CONCLUSIONS: All variables showed the positive effects of PEEP in conjunction with a recruitment maneuver. Optimal PEEP was 10 cm H2O because at this pressure level the highest compliance value in conjunction with the lowest dead space fraction indicated a maximum amount of effectively expanded alveoli. FRC and Pao2 were insensitive to alveolar over-distension.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/01.ane.0000287684.74505.49

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 176

Metadata

Authors
Maisch, S., Reissmann, H., Fuellekrug, B., Weismann, D., Rutkowski, T., Tusman, G., & Bohm, S. H.
Venue
Anesthesia & Analgesia
Published
2008-01
Volume
106
Issue
1
Pages
175-181
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2091477364
Cited by
176
References
0
FWCI
8.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Compliance and Dead Space Fraction Indicate an Optimal Level of Positive End-Expiratory Pressure After Recruitment in Anesthetized Patients. https://app.cochat.ai/papers/10.1213/01.ane.0000287684.74505.49
The paper
Maisch, S., Reissmann, H., Fuellekrug, B., Weismann, D., Rutkowski, T., Tusman, G., & Bohm, S. H. (2008). Compliance and Dead Space Fraction Indicate an Optimal Level of Positive End-Expiratory Pressure After Recruitment in Anesthetized Patients. Anesthesia & Analgesia. https://doi.org/10.1213/01.ane.0000287684.74505.49

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.