The Analgesic Efficacy of Ultrasound-Guided Transversus Abdominis Plane Block in Adult Patients: A Meta-Analysis

Baeriswyl, Moira, Kirkham, Kyle R., Kern, Christian, Albrecht, Eric·2015·Anesthesia & Analgesia

Abstract

BACKGROUND: Previous meta-analyses of the transversus abdominis plane (TAP) block have examined a maximum of 12 articles, including fewer than 650 participants, and have not examined the effect of ultrasound-guided techniques specifically. Recently, many trials that use ultrasound approaches to TAP block have been published, which report conflicting analgesic results. This meta-analysis aims to evaluate the analgesic efficacy of ultrasound-guided TAP blocks exclusively for all types of abdominal surgeries in adult patients. METHODS: This meta-analysis was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement guidelines. The primary outcome was cumulative IV morphine consumption at 6 hours postoperatively, analyzed according to the type of surgery, the type of surgical anesthesia, the timing of injection, the block approach adopted, and the presence of postoperative multimodal analgesia. Secondary outcomes included IV morphine consumption at 24 hours postoperatively; pain scores at rest and on movement at 6 and 24 hours postoperatively; and postoperative nausea and vomiting, pruritus, and rates of complications. RESULTS: Thirty-one controlled trials including 1611 adult participants were identified. Independent of the type of surgery (abdominal laparotomy, abdominal laparoscopy, and cesarean delivery) but not independent of the type of surgical anesthesia (general anesthesia, spinal anesthesia with or without intrathecal long-acting opioid), ultrasound-guided TAP block reduced IV morphine consumption at 6 hours postoperatively by a mean difference of 6 mg (95% confidence interval [CI], -7 to -4 mg; I2 = 94%; P < 0.00001). The magnitude of the reduction in morphine consumption at 6 hours postoperatively was not influenced by the timing of injection (I2 = 0%; P = 0.72), the block approach adopted (I2 = 0%; P = 0.72), or the presence of postoperative multimodal analgesia (I2 = 73%; P = 0.05). This difference persisted at 24 hours postoperatively (mean difference, -11 mg; 95% CI, -14 to -8 mg; I2 = 99%; P < 0.00001). Pain scores at rest and on movement were reduced at 6 hours postoperatively (mean difference at rest, -10; 95% CI, -15 to -5; I2 = 92%; P = 0.0002; mean difference on movement, -9; 95% CI, -14 to -5; I2 = 58%; P < 0.00001). There were neither differences in the incidence of postoperative nausea and vomiting (I2 = 1%; P = 0.59) nor in the pruritus (I2 = 12%; P = 0.58) Two minor complications (1 bruise and 1 anaphylactoid reaction) were reported in 1028 patients. CONCLUSIONS: Ultrasound-guided TAP block provides marginal postoperative analgesic efficacy after abdominal laparotomy or laparoscopy and cesarean delivery. However, it does not provide additional analgesic effect in patients who also received spinal anesthesia containing a long-acting opioid. The minimal analgesic efficacy is independent of the timing of injection, the approach adopted, or the presence of postoperative multimodal analgesia. Because of heterogeneity of the results, these findings should be interpreted with caution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/ane.0000000000000967

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 282

Metadata

Authors
Baeriswyl, M., Kirkham, K. R., Kern, C., & Albrecht, E.
Venue
Anesthesia & Analgesia
Published
2015-12
Volume
121
Issue
6
Pages
1640-1654
ISSN
0003-2999 (ISSN-L)
OpenAlex
W1834717316
Cited by
282
References
26
FWCI
18.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Analgesic Efficacy of Ultrasound-Guided Transversus Abdominis Plane Block in Adult Patients: A Meta-Analysis. https://app.cochat.ai/papers/10.1213/ane.0000000000000967
The paper
Baeriswyl, M., Kirkham, K. R., Kern, C., & Albrecht, E. (2015). The Analgesic Efficacy of Ultrasound-Guided Transversus Abdominis Plane Block in Adult Patients: A Meta-Analysis. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0000000000000967

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.