CoChat

Lung Ultrasonography for the Assessment of Perioperative Atelectasis: A Pilot Feasibility Study

Monastesse, Audrey, Girard, Francois, Massicotte, Nathalie, Chartrand-Lefebvre, Carl, Girard, Martin · 2017 · Anesthesia & Analgesia
Cited by 181

The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Few diagnostic tools are available to anesthesiologists when confronted with intraoperative hypoxemia. Lung ultrasonography is a safe and accurate bedside imaging modality. The aim of this study was to evaluate the feasibility of lung ultrasonography during the perioperative period and assess its ability to detect intraoperative respiratory complications and oxygenation changes resulting from perioperative atelectasis. METHODS: In this prospective observational pilot study, 30 consecutive patients scheduled for laparoscopic surgery were recruited. Mechanical ventilation was standardized. Lung ultrasonography was performed at 5 predefined time points: before induction of general anesthesia (GA), after induction of GA, after pneumoperitoneum insufflation, on arrival in the recovery room, and before recovery room discharge. For each echographic examination, 12 pulmonary quadrants were imaged. From these, a semiquantitative score, the lung ultrasound (LUS) score, was calculated to assess lung aeration at each time point. RESULTS: Lung ultrasonography was possible in all patients. Changes in the LUS score between the postinduction period and arrival in the recovery room were correlated with changes in oxygenation (Spearman r = −0.43, P = .018). Induction of GA was associated with an increase in the LUS score, which gradually worsened at all time points until recovery room discharge. This increase was significantly worse in the basal and dependent lung zones. Lung ultrasonography helped in the detection of 2 capnothoraces, 1 endobronchial intubation, and 1 episode of subclinical pulmonary edema. CONCLUSIONS: Lung ultrasonography in the perioperative period is feasible, allows tracking of perioperative atelectasis, and facilitates the diagnosis of respiratory complications. The evolution of aeration loss correlates moderately with changes in oxygenation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/ane.0000000000001603

Cites

54 of 54 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 54 references

Cited by

See all 181

Metadata

Authors
Monastesse, A., Girard, F., Massicotte, N., Chartrand-Lefebvre, C., & Girard, M.
Venue
Anesthesia & Analgesia
Published
2017-02
Volume
124
Issue
2
Pages
494-504
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2411981592
Cited by
181
References
54
FWCI
5.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Lung Ultrasonography for the Assessment of Perioperative Atelectasis: A Pilot Feasibility Study. https://app.cochat.ai/papers/10.1213/ane.0000000000001603
The paper
Monastesse, A., Girard, F., Massicotte, N., Chartrand-Lefebvre, C., & Girard, M. (2017). Lung Ultrasonography for the Assessment of Perioperative Atelectasis: A Pilot Feasibility Study. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0000000000001603

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.