The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Continuous Pulse Oximetry and Capnography Monitoring for Postoperative Respiratory Depression and Adverse Events: A Systematic Review and Meta-analysis
Open accessAbstract
BACKGROUND: Death and anoxic brain injury from unrecognized postoperative respiratory depression (PORD) is a serious concern for patient safety. The American Patient Safety Foundation has called for continuous electronic monitoring for all patients receiving opioids in the postoperative period. These recommendations are based largely on consensus opinion with currently limited evidence. The objective of this study is to review the current state of knowledge on the effectiveness of continuous pulse oximetry (CPOX) versus routine nursing care and the effectiveness of continuous capnography monitoring with or without pulse oximetry for detecting PORD and preventing postoperative adverse events in the surgical ward. METHODS: We performed a systematic search of the literature databases published between 1946 and May 2017. We selected the studies that included the following: (1) adult surgical patients (>18 years old); (2) prescribed opioids during the postoperative period; (3) monitored with CPOX and/or capnography; (4) primary outcome measures were oxygen desaturation, bradypnea, hypercarbia, rescue team activation, intensive care unit (ICU) admission, or mortality; and (5) studies published in the English language. Meta-analysis was performed using Cochrane Review Manager 5.3. RESULTS: In total, 9 studies (4 examining CPOX and 5 examining continuous capnography) were included in this systematic review. In the literature on CPOX, 1 randomized controlled trial showed no difference in ICU transfers (6.7% vs 8.5%; P = .33) or mortality (2.3% vs 2.2%). A prospective historical controlled trial demonstrated a significant reduction in ICU transfers (5.6–1.2 per 1000 patient days; P = .01) and rescue team activation (3.4–1.2 per 1000 patient days; P = .02) when CPOX was used. Overall, comparing the CPOX group versus the standard monitoring group, there was 34% risk reduction in ICU transfer (P = .06) and odds of recognizing desaturation (oxygen saturation [Sp o 2] <90% >1 hour) was 15 times higher (P < .00001). Pooled data from 3 capnography studies showed that continuous capnography group identified 8.6% more PORD events versus pulse oximetry monitoring group (CO 2 group versus Sp o 2 group: 11.5% vs 2.8%; P < .00001). The odds of recognizing PORD was almost 6 times higher in the capnography versus the pulse oximetry group (odds ratio: 5.83, 95% confidence interval, 3.54–9.63; P < .00001). No studies examined the impact of continuous capnography on reducing rescue team activation, ICU transfers, or mortality. CONCLUSIONS: The use of CPOX on the surgical ward is associated with significant improvement in the detection of oxygen desaturation versus intermittent nursing spot-checks. There is a trend toward less ICU transfers with CPOX versus standard monitoring. The evidence on whether the detection of oxygen desaturation leads to less rescue team activation and mortality is inconclusive. Capnography provides an early warning of PORD before oxygen desaturation, especially when supplemental oxygen is administered. Improved education regarding monitoring and further research with high-quality randomized controlled trials is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Postoperative Opioid-induced Respiratory Depression: A Closed Claims Analysis
Lee, L. A., Caplan, R. A., Stephens, L. S., Posner, K. L., Terman, G. W., Voepel-Lewis, T., & Domino, K. B. (2015) · Anesthesiology · doi:10.1097/aln.0000000000000564 · Cited by 451
Chung, F., Memtsoudis, S. G., Ramachandran, S. K., Nagappa, M., Opperer, M., Cozowicz, C., Patrawala, S., Lam, D., Kumar, A., Joshi, G. P., et al. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001416 · Cited by 360
Self-citationOpperer, M., Cozowicz, C., Bugada, D., Mokhlesi, B., Kaw, R., Auckley, D., Chung, F., & Memtsoudis, S. G. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001178 · Cited by 219
Self-citation
Cited by
Introduction to systematic review and meta-analysis
Ahn, E., & Kang, H. (2018) · Korean Journal of Anesthesiology · doi:10.4097/kjae.2018.71.2.103 · Cited by 628
Klum, M., Urban, M., Tigges, T., Pielmus, A.-G., Feldheiser, A., Schmitt, T., & Orglmeister, R. (2020) · Sensors · doi:10.3390/s20072033 · Cited by 75
Suen, C., Wong, J., Ryan, C. M., Goh, S., Got, T., Chaudhry, R., Lee, D. S., & Chung, F. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9040989 · Cited by 37
“A recent systematic review and meta-analysis of adult surgical patients who were prescribed opioids showed that receiving continuous pulse oximetry improved the detection of oxyhemoglobin desaturation and there was a trend towards less ICU transfers when compared to intermittent nursing spot checks [74].”
BackgroundSelf-citationBaldo, B. A. (2025) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.00314.2024 · Cited by 25
Metadata
- Authors
- Lam, T., Nagappa, M., Wong, J., Singh, M., Wong, D., & Chung, F.
- Venue
- Anesthesia & Analgesia
- Published
- 2017-12
- Volume
- 125
- Issue
- 6
- Pages
- 2019-2029
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2921430008
- Cited by
- 182
- References
- 3
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous Pulse Oximetry and Capnography Monitoring for Postoperative Respiratory Depression and Adverse Events: A Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.1213/ane.0000000000002557
- The paper
- Lam, T., Nagappa, M., Wong, J., Singh, M., Wong, D., & Chung, F. (2017). Continuous Pulse Oximetry and Capnography Monitoring for Postoperative Respiratory Depression and Adverse Events: A Systematic Review and Meta-analysis. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0000000000002557
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.