Continuous Pulse Oximetry and Capnography Monitoring for Postoperative Respiratory Depression and Adverse Events: A Systematic Review and Meta-analysis
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Death and anoxic brain injury from unrecognized postoperative respiratory depression (PORD) is a serious concern for patient safety. The American Patient Safety Foundation has called for continuous electronic monitoring for all patients receiving opioids in the postoperative period. These recommendations are based largely on consensus opinion with currently limited evidence. The objective of this study is to review the current state of knowledge on the effectiveness of continuous pulse oximetry (CPOX) versus routine nursing care and the effectiveness of continuous capnography monitoring with or without pulse oximetry for detecting PORD and preventing postoperative adverse events in the surgical ward. METHODS: We performed a systematic search of the literature databases published between 1946 and May 2017. We selected the studies that included the following: (1) adult surgical patients (>18 years old); (2) prescribed opioids during the postoperative period; (3) monitored with CPOX and/or capnography; (4) primary outcome measures were oxygen desaturation, bradypnea, hypercarbia, rescue team activation, intensive care unit (ICU) admission, or mortality; and (5) studies published in the English language. Meta-analysis was performed using Cochrane Review Manager 5.3. RESULTS: In total, 9 studies (4 examining CPOX and 5 examining continuous capnography) were included in this systematic review. In the literature on CPOX, 1 randomized controlled trial showed no difference in ICU transfers (6.7% vs 8.5%; P = .33) or mortality (2.3% vs 2.2%). A prospective historical controlled trial demonstrated a significant reduction in ICU transfers (5.6–1.2 per 1000 patient days; P = .01) and rescue team activation (3.4–1.2 per 1000 patient days; P = .02) when CPOX was used. Overall, comparing the CPOX group versus the standard monitoring group, there was 34% risk reduction in ICU transfer (P = .06) and odds of recognizing desaturation (oxygen saturation [Sp o 2] <90% >1 hour) was 15 times higher (P < .00001). Pooled data from 3 capnography studies showed that continuous capnography group identified 8.6% more PORD events versus pulse oximetry monitoring group (CO 2 group versus Sp o 2 group: 11.5% vs 2.8%; P < .00001). The odds of recognizing PORD was almost 6 times higher in the capnography versus the pulse oximetry group (odds ratio: 5.83, 95% confidence interval, 3.54–9.63; P < .00001). No studies examined the impact of continuous capnography on reducing rescue team activation, ICU transfers, or mortality. CONCLUSIONS: The use of CPOX on the surgical ward is associated with significant improvement in the detection of oxygen desaturation versus intermittent nursing spot-checks. There is a trend toward less ICU transfers with CPOX versus standard monitoring. The evidence on whether the detection of oxygen desaturation leads to less rescue team activation and mortality is inconclusive. Capnography provides an early warning of PORD before oxygen desaturation, especially when supplemental oxygen is administered. Improved education regarding monitoring and further research with high-quality randomized controlled trials is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Codeine Intoxication Associated with Ultrarapid CYP2D6 Metabolism
Gasche, Y., Daali, Y., Fathi, M., Chiappe, A., Cottini, S., Dayer, P., & Desmeules, J. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa041888 · Cited by 702
Opioids in renal failure and dialysis patients
Dean, M. (2004) · Journal of Pain and Symptom Management · doi:10.1016/j.jpainsymman.2004.02.021 · Cited by 501
Monitor Alarm Fatigue: Standardizing Use of Physiological Monitors and Decreasing Nuisance Alarms
Graham, K. C., & Cvach, M. (2010) · American Journal of Critical Care · doi:10.4037/ajcc2010651 · Cited by 459
Postoperative Opioid-induced Respiratory Depression: A Closed Claims Analysis
Lee, L. A., Caplan, R. A., Stephens, L. S., Posner, K. L., Terman, G. W., Voepel-Lewis, T., & Domino, K. B. (2015) · Anesthesiology · doi:10.1097/aln.0000000000000564 · Cited by 451
Chung, F., Memtsoudis, S. G., Ramachandran, S. K., Nagappa, M., Opperer, M., Cozowicz, C., Patrawala, S., Lam, D., Kumar, A., Joshi, G. P., et al. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001416 · Cited by 360
Self-citationPostoperative Hypoxemia Is Common and Persistent: A Prospective Blinded Observational Study
Sun, Z., Sessler, D. I., Dalton, J. E., Devereaux, P., Shahinyan, A., Naylor, A. J., Hutcherson, M. T., Finnegan, P. S., Tandon, V., Darvish-Kazem, S., et al. (2015) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000836 · Cited by 341
Taenzer, A. H., Pyke, J. B., McGrath, S. P., & Blike, G. T. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181ca7a9b · Cited by 315
Niesters, M., Dahan, A., Kest, B., Zacny, J., Stijnen, T., Aarts, L., & Sarton, E. (2010) · Pain · doi:10.1016/j.pain.2010.06.012 · Cited by 286
Jarzyna, D., Jungquist, C. R., Pasero, C., Willens, J. S., Nisbet, A., Oakes, L., Dempsey, S. J., Santangelo, D., & Polomano, R. C. (2011) · Pain Management Nursing · doi:10.1016/j.pmn.2011.06.008 · Cited by 253
Pulse oximetry for perioperative monitoring
Pedersen, T., Nicholson, A., Hovhannisyan, K., Møller, A. M., Smith, A. F., & Lewis, S. R. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002013.pub3 · Cited by 249
Respiratory depression associated with patient-controlled analgesia: a review of eight cases
Etches, R. C. (1994) · Canadian Journal of Anaesthesia · doi:10.1007/bf03009805 · Cited by 222
Opperer, M., Cozowicz, C., Bugada, D., Mokhlesi, B., Kaw, R., Auckley, D., Chung, F., & Memtsoudis, S. G. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001178 · Cited by 219
Self-citationContinuous Monitoring in an Inpatient Medical-Surgical Unit: A Controlled Clinical Trial
Brown, H., Terrence, J., Vasquez, P., Bates, D. W., & Zimlichman, E. (2014) · The American Journal of Medicine · doi:10.1016/j.amjmed.2013.12.004 · Cited by 211
Correa, D., Farney, R. J., Chung, F., Prasad, A., Lam, D., & Wong, J. (2015) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000672 · Cited by 198
Self-citationOverdyk, F. J., Carter, R., Maddox, R. R., Callura, J., Herrin, A. E., & Henriquez, C. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000269489.26048.63 · Cited by 191
Chung, F., Liao, P., Yegneswaran, B., Shapiro, C. M., & Kang, W. (2014) · Anesthesiology · doi:10.1097/aln.0000000000000040 · Cited by 186
Self-citationPostoperative day one: a high risk period for respiratory events
Taylor, S., Kirton, O. C., Staff, I., & Kozol, R. A. (2005) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2005.07.015 · Cited by 184
Factors Associated with Postoperative Exacerbation of Sleep-disordered Breathing
Chung, F., Liao, P., Elsaid, H., Shapiro, C. M., & Kang, W. (2014) · Anesthesiology · doi:10.1097/aln.0000000000000041 · Cited by 181
Self-citationA Review of Current and Emerging Approaches to Address Failure-to-Rescue
Taenzer, A. H., Pyke, J. B., McGrath, S. P., & Warner, D. S. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318219d633 · Cited by 177
Ramachandran, S. K., Haider, N., Saran, K. A., Mathis, M., Kim, J., Morris, M., & O'Reilly, M. (2011) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2010.09.003 · Cited by 162
Eberhard, P. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000278642.16117.f8 · Cited by 161
Capnography Outside the Operating Rooms
Kodali, B. S. (2013) · Anesthesiology · doi:10.1097/aln.0b013e318278c8b6 · Cited by 158
Opioid-induced respiratory depression in paediatrics: a review of case reports
Niesters, M., Overdyk, F. J., Smith, T., Aarts, L. P. H. J., & Dahan, A. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes447 · Cited by 136
Transcutaneous Pco2 monitoring in critically ill adults: Clinical evaluation of a new sensor*
Bendjelid, K., Schütz, N., Stotz, M., Gerard, I., Suter, P. M., & Romand, J.-A. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000181734.26070.26 · Cited by 134
Predictors of Delayed Postoperative Respiratory Depression Assessed from Naloxone Administration
Weingarten, T. N., Herasevich, V., McGlinch, M. C., Beatty, N. C., Christensen, E. D., Hannifan, S. K., Koenig, A. E., Klanke, J., Zhu, X., Gali, B., et al. (2015) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000792 · Cited by 125
Weingarten, T. N., Jacob, A. K., Njathi, C. W., Wilson, G. A., & Šprung, J. (2015) · Regional Anesthesia & Pain Medicine · doi:10.1097/aap.0000000000000257 · Cited by 118
Medical device alarm safety in hospitals.
(2013) · PubMed · Cited by 117
Noninvasive Monitoring of Carbon Dioxide During Respiratory Failure in Toddlers and Infants
Tobias, J. D., & Meyer, D. J. (1997) · Anesthesia & Analgesia · doi:10.1097/00000539-199707000-00010 · Cited by 106
Calzavacca, P., Licari, E., Tee, A. K. H., Egi, M., Haase, M., Haase‐Fielitz, A., & Bellomo, R. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1229-y · Cited by 102
The benefits and pitfalls of pulse oximetry.
Hutton, P., & Clutton-Brock, T. (1993) · BMJ · doi:10.1136/bmj.307.6902.457 · Cited by 91
Aarrestad, S., Tollefsen, E., Kleiven, A. L., Qvarfort, M., Janssens, J.-P., & Skjønsberg, O. H. (2016) · Respiratory Medicine · doi:10.1016/j.rmed.2016.01.017 · Cited by 86
Taenzer, A. H., Pyke, J., Herrick, M. D., Dodds, T. M., & McGrath, S. P. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000049 · Cited by 82
Predictors of In-hospital Postoperative Opioid Overdose After Major Elective Operations
Cauley, C. E., Anderson, G. M., Haynes, A. B., Menendez, M. E., Bateman, B. T., & Ladha, K. S. (2016) · Annals of Surgery · doi:10.1097/sla.0000000000001945 · Cited by 79
Opioid-Induced Respiratory Depression in the Acute Care Setting: A Compendium of Case Reports
Overdyk, F. J., Dahan, A., Roozekrans, M., van der Schrier, R. M., Aarts, L. P. H. J., & Niesters, M. (2014) · Pain Management · doi:10.2217/pmt.14.19 · Cited by 78
Postoperative Oxygen Therapy in Patients With OSA
Liao, P., Wong, J., Singh, M., Wong, D. T., Islam, S., Andrawes, M., Shapiro, C. M., White, D. P., & Chung, F. F. (2016) · CHEST Journal · doi:10.1016/j.chest.2016.12.005 · Cited by 78
Self-citationRonen, M., Weissbrod, R., Overdyk, F. J., & Ajizian, S. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-016-9851-7 · Cited by 74
High-inspired oxygen concentration further impairs opioid-induced respiratory depression
Niesters, M., Mahajan, R. P., Aarts, L. P. H. J., & Dahan, A. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aes494 · Cited by 70
Curry, J. P., & Jungquist, C. R. (2014) · Patient Safety in Surgery · doi:10.1186/1754-9493-8-29 · Cited by 63
Slight, S. P., Franz, C., Olugbile, M., Brown, H. V., Bates, D. W., & Zimlichman, E. (2014) · Critical Care Medicine · doi:10.1097/ccm.0000000000000340 · Cited by 62
Capnography monitoring enhances safety of postoperative patient-controlled analgesia.
McCarter, T. G., Shaik, Z., Scarfo, K. A., & Thompson, L. J. (2008) · Europe PMC (PubMed Central) · Cited by 57
Voepel‐Lewis, T., Parker, M. L., Burke, C. N., Hemberg, J., Perlin, L., Kai, S., & Ramachandran, S. K. (2013) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2013.02.006 · Cited by 55
Ochroch, E. A., Russell, M. W., Hanson, W. C., Devine, G. A., Cucchiara, A. J., Weiner, M. G., & Schwartz, S. J. (2006) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000195583.76486.c4 · Cited by 55
Williams, G. W., George, C. A., Harvey, B. C., & Freeman, J. E. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001395 · Cited by 48
Postoperative Sleep-Disordered Breathing in Patients Without Preoperative Sleep Apnea
Chung, F. F., Liao, P., Yang, Y., Andrawes, M., Kang, W., Mokhlesi, B., & Shapiro, C. M. (2015) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000774 · Cited by 37
Self-citationMcGrath, S. P., Pyke, J., & Taenzer, A. H. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-016-9884-y · Cited by 35
Timing of postoperative respiratory emergencies: when do they really occur?
Weingarten, T. N., Warner, L. L., & Šprung, J. (2016) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0000000000000401 · Cited by 34
Capnography standards for outside the operating room
Whitaker, D., & Benson, J. (2016) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0000000000000355 · Cited by 31
Evaluation of a transcutaneous carbon dioxide monitor in patients with acute respiratory failure
Nicolini, A., & Ferrari, M. (2011) · Annals of Thoracic Medicine · doi:10.4103/1817-1737.84776 · Cited by 30
Rosenfeld, D. M., Betcher, J. A., Shah, R. A., Chang, Y.-H. H., Cheng, M., Cubillo, E. I., Griffin, J. M., & Trentman, T. L. (2015) · Pain Practice · doi:10.1111/papr.12277 · Cited by 29
Galvagno, S. M., Duke, P. G., Eversole, D., & George, E. (2016) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0000000000001152 · Cited by 20
Continuous Postoperative Electronic Monitoring and the Will to Require It
Stoelting, R. K. (2015) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000857 · Cited by 15
Cited by
Introduction to systematic review and meta-analysis
Ahn, E., & Kang, H. (2018) · Korean Journal of Anesthesiology · doi:10.4097/kjae.2018.71.2.103 · Cited by 628
Khanna, A. K., Bergese, S. D., Jungquist, C. R., Morimatsu, H., Uezono, S., Lee, S., Ti, L. K., Urman, R. D., McIntyre, R., Tornero, C., et al. (2020) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000004788 · Cited by 209
Perioperative Pain Management and Opioid Stewardship: A Practical Guide
Hyland, S. J., Brockhaus, K. K., Vincent, W. R., Spence, N. Z., Lucki, M. M., Howkins, M. J., & Cleary, R. K. (2021) · Healthcare · doi:10.3390/healthcare9030333 · Cited by 206
Klum, M., Urban, M., Tigges, T., Pielmus, A.-G., Feldheiser, A., Schmitt, T., & Orglmeister, R. (2020) · Sensors · doi:10.3390/s20072033 · Cited by 75
Suen, C., Wong, J., Ryan, C. M., Goh, S., Got, T., Chaudhry, R., Lee, D. S., & Chung, F. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9040989 · Cited by 37
“A recent systematic review and meta-analysis of adult surgical patients who were prescribed opioids showed that receiving continuous pulse oximetry improved the detection of oxyhemoglobin desaturation and there was a trend towards less ICU transfers when compared to intermittent nursing spot checks [74].”
BackgroundSelf-citation
Metadata
- Authors
- Lam, T., Nagappa, M., Wong, J., Singh, M., Wong, D., & Chung, F.
- Venue
- Anesthesia & Analgesia
- Published
- 2017-12
- Volume
- 125
- Issue
- 6
- Pages
- 2019-2029
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2921430008
- Cited by
- 182
- References
- 51
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.