Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 306

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

Consensus Statement on Perioperative Use of Neuromuscular Monitoring

Open access
Naguib, Mohamed, Brull, Sorin J., Kopman, Aaron F., Hunter, Jennifer M., Fülesdi, Béla, Arkes, Hal R., Elstein, Arthur, Todd, Michael M., Johnson, Ken B.·2018·Anesthesia & Analgesia

Abstract

A panel of clinician scientists with expertise in neuromuscular blockade (NMB) monitoring was convened with a charge to prepare a consensus statement on indications for and proper use of such monitors. The aims of this article are to: (a) provide the rationale and scientific basis for the use of quantitative NMB monitoring; (b) offer a set of recommendations for quantitative NMB monitoring standards; (c) specify educational goals; and (d) propose training recommendations to ensure proper neuromuscular monitoring and management. The panel believes that whenever a neuromuscular blocker is administered, neuromuscular function must be monitored by observing the evoked muscular response to peripheral nerve stimulation. Ideally, this should be done at the hand muscles (not the facial muscles) with a quantitative (objective) monitor. Objective monitoring (documentation of train-of-four ratio ≥0.90) is the only method of assuring that satisfactory recovery of neuromuscular function has taken place. The panel also recommends that subjective evaluation of the responses to train-of-four stimulation (when using a peripheral nerve stimulator) or clinical tests of recovery from NMB (such as the 5-second head lift) should be abandoned in favor of objective monitoring. During an interim period for establishing these recommendations, if only a peripheral nerve stimulator is available, its use should be mandatory in any patient receiving a neuromuscular blocking drug. The panel acknowledges that publishing this statement per se will not result in its spontaneous acceptance, adherence to its recommendations, or change in routine practice. Implementation of objective monitoring will likely require professional societies and anesthesia department leadership to champion its use to change anesthesia practitioner behavior.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/ane.0000000000002670

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 41 references

Cited by

See all 306

Metadata

Authors
Naguib, M., Brull, S. J., Kopman, A. F., Hunter, J. M., Fülesdi, B., Arkes, H. R., Elstein, A., Todd, M. M., & Johnson, K. B.
Venue
Anesthesia & Analgesia
Published
2018-07
Volume
127
Issue
1
Pages
71-80
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2772928337
Cited by
306
References
41
FWCI
35.95
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Consensus Statement on Perioperative Use of Neuromuscular Monitoring. https://app.cochat.ai/papers/10.1213/ane.0000000000002670
The paper
Naguib, M., Brull, S. J., Kopman, A. F., Hunter, J. M., Fülesdi, B., Arkes, H. R., Elstein, A., Todd, M. M., & Johnson, K. B. (2018). Consensus Statement on Perioperative Use of Neuromuscular Monitoring. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0000000000002670

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.