The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Minimally Invasive Cardiac Output Monitoring in the Perioperative Setting
Abstract
In Brief With advancing age and increased co-morbidities in patients, the need for monitoring devices during the perioperative period that allow clinicians to track physiologic variables, such as cardiac output (CO), fluid responsiveness and tissue perfusion, is increasing. Until recently, the only tool available to anesthesiologists to monitor CO was either a pulmonary artery catheter or transesophageal echocardiograph. These devices have their limitations and potential for morbidity. Several new devices (including esophageal Doppler monitors, pulse contour analysis, indicator dilution, thoracic bioimpedance and partial non-rebreathing systems) have recently been marketed which have the ability to monitor CO noninvasively and, in some cases, assess the patient’s ability to respond to fluid challenges. In this review, we will describe these new devices including the technology, studies on their efficacy and the limitations of their use. IMPLICATIONS: Due to the rapid increase in the number of devices that measure CO noninvasively, clinicians need to familiarize themselves with the technologies and available literature to appreciate the proven indications and the questions that remain to be answered to determine the roles of each technology in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Early goal-directed therapy in the treatment of severe sepsis and septic shock
Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., Peterson, E., & Tomlanovich, M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010307 · Cited by 10,743
Cited by
Peng, K., Li, J., Cheng, H., & Ji, F.-H. (2014) · Medical Principles and Practice · doi:10.1159/000363573 · Cited by 641
Peyton, P. J., & Chong, S. W. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181ee3130 · Cited by 456
‘Liberal’ vs. ‘restrictive’ perioperative fluid therapy – a critical assessment of the evidence
BUNDGAARD‐NIELSEN, M., SECHER, N. H., & KEHLET, H. (2009) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2009.02029.x · Cited by 336
Metadata
- Authors
- Funk, D. J., Moretti, E. W., & Gan, T. J.
- Venue
- Anesthesia & Analgesia
- Published
- 2009-03
- Volume
- 108
- Issue
- 3
- Pages
- 887-897
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2147246192
- Cited by
- 202
- References
- 2
- FWCI
- 20.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.