Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 192

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Ultrasound Imaging of the Lumbar Spine in the Transverse Plane: The Correlation Between Estimated and Actual Depth to the Epidural Space in Obese Parturients

Balki, Mrinalini, Lee, Yung, Halpern, Stephen, Carvalho, Jose C. A. · 2009 · Anesthesia & Analgesia

Abstract

BACKGROUND: Prepuncture lumbar ultrasound scanning is a reliable tool to facilitate labor epidural needle placement in nonobese parturients. In this study, we assessed prepuncture lumbar ultrasound scanning as a tool for estimating the depth to the epidural space and determining the optimal insertion point in obese parturients. METHODS: We studied 46 obese parturients, with prepregnancy body mass index (BMI) >30 kg/m(2), requesting labor epidural analgesia. Ultrasound imaging was done by one of the investigators to identify the midline, the intervertebral space, and the distance from the skin to the epidural space (ultrasound depth, UD) at the level of L3-4. Subsequently, an anesthesiologist blinded to the UD located the epidural space through the predetermined insertion point and marked the actual distance from the skin to the epidural space (needle depth, ND) on the needle with a sterile marker. The agreement between the UD and the ND was calculated using the Pearson correlation coefficient and a paired t-test. Bland-Altman analysis was used to determine the 95% limits of agreement between the UD and the ND. RESULTS: The prepregnancy BMI ranged from 30 to 79 kg/m(2), and the BMI at delivery was 33-86 kg/m(2). The Pearson correlation coefficient between the UD and the ND was 0.85 (95% confidence interval: 0.75-0.91), and the concordance correlation coefficient was 0.79 (95% confidence interval: 0.71-0.88). The mean (+/-SD) ND and UD were 6.6 +/- 1.0 cm and 6.3 +/- 0.8 cm, respectively (difference = 0.3 cm, P = 0.002). The 95% limits of agreement were 1.3 cm to -0.7 cm. Epidural needle placement using the predetermined insertion point was done without reinsertion at a different puncture site in 76.1% of parturients and without redirection in 67.4%. CONCLUSIONS: We found a strong correlation between the ultrasound-estimated distance to the epidural space and the actual measured needle distance in obese parturients. We suggest that prepuncture lumbar ultrasound may be a useful guide to facilitate the placement of epidural needles in obese parturients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/ane.0b013e3181a323f6

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 192

Metadata

Authors
Balki, M., Lee, Y., Halpern, S., & Carvalho, J. C. A.
Venue
Anesthesia & Analgesia
Published
2009-06
Volume
108
Issue
6
Pages
1876-1881
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2011206155
Cited by
192
References
2
FWCI
14.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.