The DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
Cardiac Output Monitoring Using Indicator-Dilution Techniques: Basics, Limits, and Perspectives
Abstract
The ability to monitor cardiac output is one of the important cornerstones of hemodynamic assessment for managing critically ill patients at increased risk for developing cardiac complications, and in particular in patients with preexisting cardiovascular comorbidities. For >30 years, single-bolus thermodilution measurement through a pulmonary artery catheter for assessment of cardiac output has been widely accepted as the "clinical standard" for advanced hemodynamic monitoring. In this article, we review this clinical standard, along with current alternatives also based on the indicator-dilution technique, such as the transcardiopulmonary thermodilution and lithium dilution techniques. In this review, not only the underlying technical principles and the unique features but also the limitations of each application of indicator dilution are outlined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
The Effectiveness of Right Heart Catheterization in the Initial Care of Critically III Patients
Connors, A. F. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540110043030 · Cited by 2,210
Catheterization of the Heart in Man with Use of a Flow-Directed Balloon-Tipped Catheter
Swan, H. J. C., Ganz, W., Forrester, J., Marcus, H., Diamond, G., & Chonette, D. (1970) · New England Journal of Medicine · doi:10.1056/nejm197008272830902 · Cited by 2,137
Sandham, J. D., Hull, R. D., Brant, R. F., Knox, L., Pineo, G. F., Doig, C. J., Laporta, D. P., Viner, S., Passerini, L., Devitt, H., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa021108 · Cited by 1,529
Critchley, L. A. H., & Critchley, J. A. J. H. (1999) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009982611386 · Cited by 1,325
Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution
Sakka, S. G., Rühl, C. C., Pfeiffer, U. J., Beale, R., McLuckie, A., Reinhart, K., & Meier-Hellmann, A. (2000) · Intensive Care Medicine · doi:10.1007/s001340050043 · Cited by 920
Scheer, B., Perel, A., & Pfeiffer, U. J. (2002) · Critical Care · doi:10.1186/cc1489 · Cited by 854
A new technique for measurement of cardiac output by thermodilution in man
Ganz, W., Donoso, R., Marcus, H. S., Forrester, J. S., & Swan, H. J. C. (1971) · The American Journal of Cardiology · doi:10.1016/0002-9149(71)90436-x · Cited by 763
Hamilton, W. F., Moore, J. W., Kinsman, J. M., & Spurling, R. G. (1932) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1932.99.3.534 · Cited by 763
Mitchell, J. P., Schuller, D., Calandrino, F. S., & Schuster, D. P. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/145.5.990 · Cited by 587
Goedje, O., Hoeke, K., Lichtwarck-Aschoff, M., Faltchauser, A., Lamm, P., & Reichart, B. (1999) · Critical Care Medicine · doi:10.1097/00003246-199911000-00014 · Cited by 576
Reinhart, K., Rudolph, T., Bredle, D. L., Hannemann, L., & Cain, S. M. (1989) · Chest · doi:10.1378/chest.95.6.1216 · Cited by 515
Stetz, C. W., Miller, R. G., Kelly, G. E., & Raffin, T. A. (1982) · PubMed · doi:10.1164/arrd.1982.126.6.1001 · Cited by 447
Researches on the Circulation Time and on the Influences which affect it
Stewart, G. N. (1897) · The Journal of Physiology · doi:10.1113/jphysiol.1897.sp000684 · Cited by 417
MEASUREMENT OF CARDIAC OUTPUT IN ANÆSTHETIZED ANIMALS BY A THERMO‐DILUTION METHOD
Fegler, G. (1954) · Quarterly Journal of Experimental Physiology and Cognate Medical Sciences · doi:10.1113/expphysiol.1954.sp001067 · Cited by 406
Cardiac Risk of Noncardiac Surgery
Eagle, K. A., Rihal, C. S., Mickel, M. C., Holmes, D. R., Foster, E. D., Gersh, B. J., & for the CASS Investigators (1997) · Circulation · doi:10.1161/01.cir.96.6.1882 · Cited by 405
EISENBERG, P. R., JAFFE, A. S., & SCHUSTER, D. P. (1984) · Critical Care Medicine · doi:10.1097/00003246-198407000-00001 · Cited by 393
Measurement of blood flow by thermodilution
Ganz, W., & Swan, H. J. C. (1972) · The American Journal of Cardiology · doi:10.1016/0002-9149(72)90635-2 · Cited by 374
STUDIES ON THE CIRCULATION: I. I njection M ethod: P hysical and M athematical C onsiderations
Kinsman, J. M., Moore, J. W., & Hamilton, W. F. (1929) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1929.89.2.322 · Cited by 337
Errors in the measurement of cardiac output by thermodilution
Nishikawa, T., & Dohi, S. (1993) · Canadian Journal of Anaesthesia · doi:10.1007/bf03011312 · Cited by 302
Pulmonary Artery Catheter Consensus Conference: Consensus Statement
(1997) · Critical Care Medicine · doi:10.1097/00003246-199706000-00006 · Cited by 285
Lowering Cardiac Risk in Noncardiac Surgery
Fleisher, L. A., & Eagle, K. A. (2001) · New England Journal of Medicine · doi:10.1056/nejmcp002842 · Cited by 257
Goal-directed fluid management reduces vasopressor and catecholamine use in cardiac surgery patients
Goepfert, M. S. G., Reuter, D. A., Akyol, D., Lamm, P., Kilger, E., & Goetz, A. E. (2007) · Intensive Care Medicine · doi:10.1007/s00134-006-0404-2 · Cited by 254
Self-citationClinicians’ abilities to estimate cardiac index in ventilated children and infants
Tibby, S. M., Hatherill, M., Marsh, M. J., & Murdoch, I. A. (1997) · Archives of Disease in Childhood · doi:10.1136/adc.77.6.516 · Cited by 224
Bernard, G. R., Sopko, G., Cerra, F., Demling, R., Edmunds, H., Kaplan, S., Kessler, L., Masur, H., Parsons, P., Shure, D., et al. (2000) · JAMA · doi:10.1001/jama.283.19.2568 · Cited by 198
A Prospective Study of Lung Water Measurements during Patient Management in an Intensive Care Unit
Eisenberg, P. R., Hansbrough, J. R., Anderson, D., & Schuster, D. P. (1987) · American Review of Respiratory Disease · doi:10.1164/ajrccm/136.3.662 · Cited by 197
A NEW METHOD OF MEASURING CARDIAC OUTPUT IN MAN USING LITHIUM DILUTION
Linton, R. A. F., Band, D. M., & HAIRE, K. M. (1993) · British Journal of Anaesthesia · doi:10.1093/bja/71.2.262 · Cited by 181
Tibby, S. M., Hatherill, M., Marsh, M. J., Morrison, G., Anderson, D., & Murdoch, I. A. (1997) · Intensive Care Medicine · doi:10.1007/s001340050443 · Cited by 178
Continuous thermodilution cardiac output measurement in intensive care unit patients
Yelderman, M., Ramsay, M. A., Quinn, M. D., Paulsen, A. W., McKown, R. C., & Ph, G. (1992) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/1053-0770(92)90137-v · Cited by 160
Bedside assessment of extravascular lung water by dilution methods: Temptations and pitfalls
Michard, F. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000259539.49339.66 · Cited by 149
Kurita, T., Morita, K., Kato, S., Kikura, M., Horie, M., & Ikeda, K. (1997) · British Journal of Anaesthesia · doi:10.1093/bja/79.6.770 · Cited by 139
Jonas, M. M., & Tanser, S. J. (2002) · Current Opinion in Critical Care · doi:10.1097/00075198-200206000-00010 · Cited by 138
Wiesenack, C., Prasser, C., Keyl, C., & Rödig, G. (2001) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/jcan.2001.26536 · Cited by 137
Pauli, C., Fakler, U., Genz, T., Hennig, M., Lorenz, H.-P., & Hess, J. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1334-2 · Cited by 122
Accurate characterization of extravascular lung water in acute respiratory distress syndrome*
Berkowitz, D. M., Danai, P. A., Eaton, S., Moss, M. M., & Martin, G. S. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181743eeb · Cited by 122
The risk of infection related to radial vs femoral sites for arterial catheterization
Thomas, F., Burke, J. P., Parker, J., Orme, J. F., Gardner, R. M., Clemmer, T. P., Hill, G., & MACFARLANE, P. (1983) · Critical Care Medicine · doi:10.1097/00003246-198310000-00009 · Cited by 113
Costa, M. G., Rocca, G. D., Chiarandini, P., Mattelig, S., Pompei, L., Sainz‐Barriga, M., Reynolds, T. E., Cecconi, M., & Pietropaoli, P. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0878-6 · Cited by 113
Linton, R. A. F., Jonas, M., Tibby, S. M., Murdoch, I., O’Brien, T. K., Linton, N., & Band, D. M. (2000) · Intensive Care Medicine · doi:10.1007/s001340051347 · Cited by 106
Cardiac Output By Thermodilution Technique
Elkayam, U., Berkley, R., Azen, S. P., Weber, L., Geva, B., & Henry, W. L. (1983) · CHEST Journal · doi:10.1378/chest.84.4.418 · Cited by 103
Hosie, K. F. (1962) · Circulation Research · doi:10.1161/01.res.10.3.491 · Cited by 99
Botero, M., Kirby, D. S., Lobato, E. B., Staples, E. D., & Gravenstein, N. L. (2004) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2004.07.005 · Cited by 98
Effect of the degree of tricuspid regurgitation on cardiac output measurements by thermodilution
Martin, B., Pachl, J., & Jan, H. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1352-0 · Cited by 97
McLuckie, A., Murdoch, I., Marsh, M., & Anderson, D. R. (1996) · Acta Paediatrica · doi:10.1111/j.1651-2227.1996.tb14027.x · Cited by 90
Prospective evaluation of radial and femoral artery catheterization sites in critically ill adults
Russell, J. A., Joel, M., HUDSON, R. J., et al. (1983) · Critical Care Medicine · doi:10.1097/00003246-198312000-00007 · Cited by 83
Rocca, C. D., Costa, M. G., Coccia, C., Pompei, L., & Pietropaoli, P. (2002) · European Journal of Anaesthesiology · doi:10.1017/s0265021502001394 · Cited by 79
Arterial cannulation: a critical review.
Cousins, T. R., & O'Donnell, J. M. (2004) · PubMed · Cited by 77
Böttiger, B. W., Rauch, H., Bohrer, H., Motsch, J., Soder, M., Fleischer, F., & Martin, E. (1995) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(05)80095-3 · Cited by 77
Schmid, E. R., Schmidlin, D., Tornic, M., & Seifert, B. (1999) · Intensive Care Medicine · doi:10.1007/s001340050811 · Cited by 74
Garcia-Rodriguez, C., Pittman, J., Cassell, C. H., Sum-Ping, J., El-Moalem, H. E., Young, C., & Mark, J. B. (2002) · Critical Care Medicine · doi:10.1097/00003246-200210000-00004 · Cited by 65
Holm, C., Melcer, B., Hörbrand, F., von Donnersmarck, G. H., & Mühlbauer, W. D. (2001) · Burns · doi:10.1016/s0305-4179(00)00088-7 · Cited by 63
Validation of transpulmonary thermodilution cardiac output measurement in a pediatric animal model
Lemson, J., de Boode, W. P., Hopman, J. C. W., Singh, S. K., & van der Hoeven, J. G. (2008) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0b013e31816c6fa1 · Cited by 62
Küntscher, M. V., Blome-Eberwein, S. A., Pelzer, M., et al. (2002) · Journal of Burn Care & Rehabilitation · doi:10.1097/00004630-200201000-00005 · Cited by 57
Friesecke, S., Heinrich, A., Abel, P., & Felix, S. B. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e31819290d5 · Cited by 53
Singh, A., Juneja, R., Mehta, Y. B., & Trehan, N. K. (2002) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/jcan.2002.31063 · Cited by 53
Superiority of the femoral artery for monitoring
Soderstrom, C. A., Wasserman, D. H., Dunham, C. M., Caplan, E. S., & Cowley, R. A. (1982) · The American Journal of Surgery · doi:10.1016/0002-9610(82)90007-1 · Cited by 53
Femoral–radial arterial pressure gradients in critically ill patients
Galluccio, S. T., Chapman, M. J., & Finnis, M. (2009) · Critical Care and Resuscitation · doi:10.1016/s1441-2772(23)01830-6 · Cited by 49
Hogue, C. W. J., Rosenbloom, M., McCawley, C., & Lappas, D. G. (1994) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/1053-0770(94)90193-7 · Cited by 46
Continuous thermodilution cardiac output: Agreement with fick and bolus thermodilution methods
Thrush, D. N., Downs, J. B., & Smith, R. A. (1995) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(05)80094-1 · Cited by 37
Pulse contour cardiac output analysis in a piglet model of severe hemorrhagic shock*
Piehl, M. D., Manning, J. E., McCurdy, S. L., Rhue, T. S., Kocis, K. C., Cairns, C. B., & Cairns, B. A. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e31816592a3 · Cited by 36
Is clinical assessment of the circulation reliable in postoperative cardiac surgical patients?
Linton, R. A., Linton, N., & Kelly, F. (2002) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/jcan.2002.29631 · Cited by 35
Comparison of continuous thermodilution and bolus cardiac output measurements in septic shock
Sun, Q., Rogiers, P., Pauwels, D., & Vincent, J. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1415-2 · Cited by 33
Segal, E., Katzenelson, R., Berkenstadt, H., & Perel, A. (2002) · Journal of Clinical Anesthesia · doi:10.1016/s0952-8180(02)00345-8 · Cited by 31
Faybik, P., Hetz, H., Baker, A., Iankovskaya, E., Krenn, C. G., & Steltzer, H. (2004) · Journal of Critical Care · doi:10.1016/j.jcrc.2004.04.002 · Cited by 31
Buffington, C. W., & Nystrom, E. U. M. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000105923.09732.93 · Cited by 22
Zöllner, C., Briegel, J., Kilger, E., & Haller, M. (1998) · Der Anaesthesist · doi:10.1007/s001010050642 · Cited by 20
Kurita, T., Morita, K., Kato, S., Kawasaki, H., Kikura, M., Kazama, T., & Ikeda, K. (1999) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009918904525 · Cited by 19
Mets, B., Frumento, R. J., Bennett-Guerrero, E., & Naka, Y. (2002) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/jcan.2002.128411 · Cited by 16
Cited by
Critchley, L. A., Lee, A., & Ho, A. M.-H. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181f08a5b · Cited by 512
Cardiac output monitoring in paediatric cardiac surgery: A review
Woodman, H. M., Lee, C., Ahmed, A. N., Malik, B. A., Mellor, S., Brown, L. J., Gentle, L., & Harky, A. (2021) · Cardiology in the Young · doi:10.1017/s1047951120004680 · Cited by 7
Metadata
- Authors
- Reuter, D. A., Huang, C., Edrich, T., Shernan, S. K., & Eltzschig, H. K.
- Venue
- Anesthesia & Analgesia
- Published
- 2010-03
- Volume
- 110
- Issue
- 3
- Pages
- 799-811
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W1976595177
- Cited by
- 284
- References
- 70
- FWCI
- 20.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.