CoChat

The Accuracy of Noninvasive and Continuous Total Hemoglobin Measurement by Pulse CO-Oximetry in Human Subjects Undergoing Hemodilution

Macknet, Mark R., Allard, Martin, Applegate, Richard L., Rook, James · 2010 · Anesthesia & Analgesia
Cited by 175

The DOI matches its Crossref record.

Abstract

BACKGROUND: Total hemoglobin (tHb) is one the most frequently ordered laboratory measurements. Pulse CO-Oximetry™ (Masimo Corp., Irvine, CA) is a multi-wavelength spectrophotometric method for noninvasive and continuous hemoglobin monitoring (SpHb). In this study, we evaluated the accuracy of SpHb compared with laboratory CO-Oximeter measurement of tHb from arterial blood samples in 20 healthy volunteer subjects undergoing hemodilution. METHODS: After enrollment, approximately 500 mL of blood was drawn from subjects through an arterial or venous catheter. Each subject then rapidly received crystalloid i.v. fluid to compensate for the decrease in intravascular volume and reduce the hemoglobin concentration. Subjects received a maximum of 30 mL/kg i.v. fluid. SpHb was continuously monitored and recorded, and serial arterial blood samples were taken during the procedure. SpHb accuracy was analyzed by pairing SpHb and tHb measurements after the arterial blood draw with the resulting tHb test result. Bias, precision, and the average root-mean-square error were calculated. RESULTS: One hundred sixty-five tHb measurements were collected. The average decrease in tHb during the blood removal and hemodilution procedure was 2.4 ± 0.8 g/dL (mean ± SD). The average difference between 335 paired measurements of SpHb and tHb was -0.15 g/dL, 1 SD of the difference was 0.92 g/dL, and the average root-mean-square difference was 0.94 g/dL. The difference between SpHb and tHb was <2.0 g/dL for 97% of the measurements. The difference was <1.5 g/dL for 97% of the measurements when tHb was <10 g/dL. CONCLUSIONS: Pulse CO-Oximetry-based SpHb measurement is accurate within 1.0 g/dL (1 SD) compared with laboratory CO-Oximeter tHb measurement in subjects undergoing hemodilution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/ane.0b013e3181fc74b9

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 175

Metadata

Authors
Macknet, M. R., Allard, M., Applegate, R. L., & Rook, J.
Venue
Anesthesia & Analgesia
Published
2010-12
Volume
111
Issue
6
Pages
1424-1426
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2068281683
Cited by
175
References
0
FWCI
16.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Accuracy of Noninvasive and Continuous Total Hemoglobin Measurement by Pulse CO-Oximetry in Human Subjects Undergoing Hemodilution. https://app.cochat.ai/papers/10.1213/ane.0b013e3181fc74b9
The paper
Macknet, M. R., Allard, M., Applegate, R. L., & Rook, J. (2010). The Accuracy of Noninvasive and Continuous Total Hemoglobin Measurement by Pulse CO-Oximetry in Human Subjects Undergoing Hemodilution. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0b013e3181fc74b9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.