Head and Neck Position for Direct Laryngoscopy
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The sniffing position (SP) has traditionally been considered the optimal head position for direct laryngoscopy (DL). Its superiority over other head positions, however, has been questioned during the last decade. We reviewed the scarce literature on the subject to examine the evidence either in favor or against the routine use of the SP. A standard definition for the position should be used (e.g., 35° neck flexion and 15° head extension) to avoid confusion about what constitutes a proper SP and to compare the results from different studies. Although several theories were proposed to explain the superiority of the SP, the three axes alignment theory is still considered a valid anatomical explanation. Although head elevation is needed to achieve the desired neck flexion, the elevation height may vary from one patient to another depending on head and neck anatomy and size of the chest. In infants and small children, for example, no head elevation is needed because the size and shape of the head allow axes approximation in the head-flat position. Horizontal alignment of the external auditory meatus with the sternum, in both obese and non-obese patients, indicates, and can be used as a marker for, proper positioning. Analysis of the available literature supports the use of the SP for DL. To achieve a proper SP in obese patients, the "ramped" (or the back-up) position should be used. The SP does not guarantee adequate exposure in all patients, because many other anatomical factors control the final degree of visualization. However, it should be the starting head position for DL because it provides the best chance at adequate exposure. Attention to details during positioning and avoidance of minor technical errors are essential to achieve the proper position. DL should be a dynamic procedure and position adjustment should be instituted in case poor visualization is encountered in the SP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Morbid Obesity and Tracheal Intubation
Brodsky, J. B., Lemmens, H. J. M., Brock-Utne, J. G., Vierra, M., & Saidman, L. J. (2002) · Anesthesia & Analgesia · doi:10.1097/00000539-200203000-00047 · Cited by 640 · cited 1×
“Obese Patients Head elevation in the supine obese patient does not alone guarantee a proper SP.(26) In this patient population, the anteroposterior diameter of the chest is increased so that it is almost impossible to obtain a neck flexion angle of 35° unless the shoulders and upper torso are also raised (Fig.”
BackgroundLaryngoscopy and Morbid Obesity: a Comparison of the "Sniff" and "Ramped" Positions
Collins, J. S., Lemmens, H. J. M., Brodsky, J. B., Brock-Utne, J. G., & Levitan, R. M. (2004) · Obesity Surgery · doi:10.1381/0960892042386869 · Cited by 411
Laryngoscopic Intubation: Learning and Performance
Mulcaster, J. T., Mills, J., Hung, O. R., MacQuarrie, K., Law, J. A., Pytka, S., Imrie, D., & Field, C. (2003) · Anesthesiology · doi:10.1097/00000542-200301000-00007 · Cited by 355
TREATMENT OF DIARRHOEA IN INDONESIAN CHILDREN: WHAT IT COSTS AND WHO PAYS FOR IT
Lerman, S., Shepard, D., & Cash, R. (1985) · The Lancet · doi:10.1016/s0140-6736(85)90013-3 · Cited by 228
Adnet, F., Baillard, C., Borron, S. W., Denantes, C., Lefebvre, L., Galinski, M., Martinez, C., Cupa, M., & Lapostolle, F. (2001) · Anesthesiology · doi:10.1097/00000542-200110000-00009 · Cited by 218 · cited 6×
“In another recent study, 10 awake volunteers had MRI scans of the head placed in both the neutral and SP.10 Unlike the Adnet et al.16 study, a proper SP was verified by using the accepted end point (flexing the neck 35° and extending the head 15°).”
BackgroundResultInfluentialDifficult direct laryngoscopy in patients with cervical spine disease
CALDER, I., CALDER, J., & CROCKARD, H. A. (1995) · Anaesthesia · doi:10.1111/j.1365-2044.1995.tb06135.x · Cited by 170 · cited 1×
“Failure to extend the head in patients with limited neck extension may result in poor visualization.(35)”
BackgroundDifficult laryngoscopy: obtaining the best view
Benumof, J. L. (1994) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03009856 · Cited by 168 · cited 1×
“It also seems that these errors (which mainly stem from failure to achieve a proper SP) are common in everyday practice.(31) Review of the literature highlighted the importance of considering the following points to obtain the best possible exposure with DL: • Placing a blanket under the head does not ensure a proper…”
BackgroundStudy of the “Sniffing Position” by Magnetic Resonance Imaging
Adnet, F., Borron, S. W., Dumas, J. L., Lapostolle, F., Cupa, M., & Lapandry, C. (2001) · Anesthesiology · doi:10.1097/00000542-200101000-00017 · Cited by 159 · cited 1×
“They could not find axes alignment in any of the studied positions and concluded that achieving this alignment is anatomically impossible.(12) This study again was criticized because the subjects were awake volunteers.”
BackgroundLevitan, R. M., Mechem, C. C., Ochroch, E. A., Shofer, F. S., & Hollander, J. E. (2003) · Annals of Emergency Medicine · doi:10.1067/mem.2003.87 · Cited by 136 · cited 1×
“Elevating the head higher than what is needed for a conventional SP was found to improve visualization in some patients.(5,23) • Although the SP is considered the optimal head position for DL, it does not guarantee a perfect exposure in all patients.”
BackgroundGreenland, K. B., Edwards, M. J., Hutton, N. J., Challis, V. J., Irwin, M. G., & Sleigh, J. W. (2010) · British Journal of Anaesthesia · doi:10.1093/bja/aeq239 · Cited by 128 · cited 5×
“It has been suggested that horizontal alignment of the external auditory meatus with the sternum may be a useful clinical end point to ensure a proper SP and subsequently improve laryngeal visualization in obese patients.9 Recently, Greenland et al.10 performed a magnetic resonance imaging (MRI) study to evaluate the…”
BackgroundInfluential
Cited by
Frerk, C., Mitchell, V. S., McNarry, A. F., Mendonca, C., Bhagrath, R., Patel, A., O’Sullivan, E. P., Woodall, N. M., & Ahmad, I. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev371 · Cited by 2,214
Myatra, S. N., Shah, A., Kundra, P., Patwa, A., Ramkumar, V., Divatia, J. V., Raveendra, U. S., Shetty, S. R., Ahmed, S. M., Doctor, J. R., et al. (2016) · Indian Journal of Anaesthesia · doi:10.4103/0019-5049.195481 · Cited by 294
Law, J. A., Duggan, L. V., Asselin, M., Baker, P., Crosby, E., Downey, A., Hung, O. R., Kovacs, G., Lemay, F., Noppens, R., et al. (2021) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-021-02008-z · Cited by 203
Metadata
- Authors
- El-Orbany, M., Woehlck, H., & Salem, M. R.
- Venue
- Anesthesia & Analgesia
- Published
- 2011-07
- Volume
- 113
- Issue
- 1
- Pages
- 103-109
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2331400488
- Cited by
- 184
- References
- 18
- FWCI
- 11.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.