CoChat

Head and Neck Position for Direct Laryngoscopy

El-Orbany, Mohammad, Woehlck, Harvey, Salem, M. Ramez · 2011 · Anesthesia & Analgesia
Cited by 184

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

The sniffing position (SP) has traditionally been considered the optimal head position for direct laryngoscopy (DL). Its superiority over other head positions, however, has been questioned during the last decade. We reviewed the scarce literature on the subject to examine the evidence either in favor or against the routine use of the SP. A standard definition for the position should be used (e.g., 35° neck flexion and 15° head extension) to avoid confusion about what constitutes a proper SP and to compare the results from different studies. Although several theories were proposed to explain the superiority of the SP, the three axes alignment theory is still considered a valid anatomical explanation. Although head elevation is needed to achieve the desired neck flexion, the elevation height may vary from one patient to another depending on head and neck anatomy and size of the chest. In infants and small children, for example, no head elevation is needed because the size and shape of the head allow axes approximation in the head-flat position. Horizontal alignment of the external auditory meatus with the sternum, in both obese and non-obese patients, indicates, and can be used as a marker for, proper positioning. Analysis of the available literature supports the use of the SP for DL. To achieve a proper SP in obese patients, the "ramped" (or the back-up) position should be used. The SP does not guarantee adequate exposure in all patients, because many other anatomical factors control the final degree of visualization. However, it should be the starting head position for DL because it provides the best chance at adequate exposure. Attention to details during positioning and avoidance of minor technical errors are essential to achieve the proper position. DL should be a dynamic procedure and position adjustment should be instituted in case poor visualization is encountered in the SP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/ane.0b013e31821c7e9c

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 184

Metadata

Authors
El-Orbany, M., Woehlck, H., & Salem, M. R.
Venue
Anesthesia & Analgesia
Published
2011-07
Volume
113
Issue
1
Pages
103-109
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2331400488
Cited by
184
References
18
FWCI
11.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.