CoChat

Programmed Intermittent Epidural Bolus Versus Continuous Epidural Infusion for Labor Analgesia: The Effects on Maternal Motor Function and Labor Outcome. A Randomized Double-Blind Study in Nulliparous Women

Capogna, Giorgio, Camorcia, Michela, Stirparo, Silvia, Farcomeni, Alessio · 2011 · Anesthesia & Analgesia
Cited by 195

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Programmed intermittent epidural anesthetic bolus (PIEB) technique may result in reduced total local anesthetic consumption, fewer manual boluses, and greater patient satisfaction compared with continuous epidural infusion (CEI). In this randomized, double-blind study, we compared the incidence of motor block and labor outcome in women who received PIEB or CEI for maintenance of labor analgesia. The primary outcome variable was maternal motor function and the secondary outcome was mode of delivery. METHODS: Nulliparous, term women with spontaneous labor and cervical dilation <4 cm were eligible to participate in the study. Epidural analgesia was initiated and maintained with a solution of levobupivacaine 0.0625% with sufentanil 0.5 μg/mL. After an initial epidural loading dose of 20 mL, patients were randomly assigned to receive PIEB (10 mL every hour beginning 60 minutes after the initial dose) or CEI (10 mL/h, beginning immediately after the initial dose) for the maintenance of analgesia. Patient-controlled epidural analgesia (PCEA) using a second infusion pump with levobupivacaine 0.125% was used to treat breakthrough pain. The degree of motor block was assessed in both lower extremities using the modified Bromage score at regular intervals throughout labor; the end point was any motor block in either limb. We also evaluated PCEA bolus doses and total analgesic solution consumption. RESULTS: We studied 145 subjects (PIEB = 75; CEI = 70). Motor block was reported in 37% in the CEI group and in 2.7% in the PIEB group (P < 0.001; odds ratio = 21.2; 95% CI: 4.9-129.3); it occurred earlier (P = 0.008) (hazard ratio = 7.8; 95% CI: 1.9-30.8; P = 0.003) and was more frequent at full cervical dilation in the CEI group (P < 0.001). The incidence of instrumental delivery was 20% for the CEI group and 7% for the PIEB group (P = 0.03). Total levobupivacaine consumption, number of patients requiring additional PCEA boluses, and mean number of PCEA boluses per patient were lower in the PIEB group (P < 0.001). No differences in pain scores and duration of labor analgesia were observed. CONCLUSIONS: Maintenance of epidural analgesia with PIEB compared with CEI resulted in a lower incidence of maternal motor block and instrumental vaginal delivery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/ane.0b013e31822827b8

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 195

Metadata

Authors
Capogna, G., Camorcia, M., Stirparo, S., & Farcomeni, A.
Venue
Anesthesia & Analgesia
Published
2011-10
Volume
113
Issue
4
Pages
826-831
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2317109081
Cited by
195
References
5
FWCI
6.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Programmed Intermittent Epidural Bolus Versus Continuous Epidural Infusion for Labor Analgesia: The Effects on Maternal Motor Function and Labor Outcome. A Randomized Double-Blind Study in Nulliparous Women. https://app.cochat.ai/papers/10.1213/ane.0b013e31822827b8
The paper
Capogna, G., Camorcia, M., Stirparo, S., & Farcomeni, A. (2011). Programmed Intermittent Epidural Bolus Versus Continuous Epidural Infusion for Labor Analgesia: The Effects on Maternal Motor Function and Labor Outcome. A Randomized Double-Blind Study in Nulliparous Women. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0b013e31822827b8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.