An Initial Evaluation of a Novel Anesthetic Scavenging Interface
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Waste anesthetic gas scavenging technology has not changed appreciably in the past 30 years. Open reservoir systems entrain high volumes of room air and dilute waste gases before emission into the atmosphere. This process requires a large vacuum pump, which is both costly to install and, although efficient, operates continuously and at near-full capacity. In an era of increasing energy costs and environmental awareness, carbon footprint reduction is a priority and a more efficient system of safely scavenging waste anesthetic gases is desirable. We tested a low-flow scavenger interface to evaluate the potential for cost and energy savings. The use of this interface in a suite of 4 operating rooms reduced scavenging flow from a constant 37 L/min to a value equal to the fresh gas flow (usually 2 L/min) for each anesthesia machine. Using the ventilator increased this flow by approximately 6 L/min because of the exhaust of ventilator drive gas into the scavenging circuit. Daytime workload of the central vacuum pump decreased from 92% to 12% (expressed as duty cycle). The new system produces energy savings and may increase vacuum pump lifespan.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global Warming Potential of Inhaled Anesthetics: Application to Clinical Use
Ryan, S. M., & Nielsen, C. J. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181e058d7 · Cited by 340
Cited by
Life cycle greenhouse gas emissions of anesthetic drugs
Sherman, J., Le, C., Lamers, V., & Eckelman, M. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31824f6940 · Cited by 496
“has minimal impact on heating, ventilation, and air conditioning energy usage.(21) Deltasorb is an alternative tech-”
BackgroundEnvironmental sustainability in anaesthesia and critical care
McGain, F., Muret, J., Lawson, C., & Sherman, J. D. (2020) · British Journal of Anaesthesia · doi:10.1016/j.bja.2020.06.055 · Cited by 455
Carbon footprint of general, regional, and combined anesthesia for total knee replacements
McGain, F., Sheridan, N., Wickramarachchi, K., Yates, S., Chan, B., & McAlister, S. (2021) · Anesthesiology · doi:10.1097/aln.0000000000003967 · Cited by 144
“8 kilowatt-hours/h) from online data for Model 775, Bair Hugger, USA.(21) Anesthetic machine electricity use (0.”
MethodInfluentialAtmospheric science, anaesthesia, and the environment
Campbell, M., & Pierce, J. M. T. (2015) · BJA Education · doi:10.1093/bjaceaccp/mku033 · Cited by 103
Rübsam, M.-L., Kruse, P., Dietzler, Y., Kropf, M., Bette, B., Zarbock, A., Kim, S.-C., & Hönemann, C. (2023) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-022-02393-z · Cited by 39
“Thus, minimal or metabolic flow anesthesia is essential to use these technologies beneficially in the future.(68)”
Background
Metadata
- Authors
- Barwise, J. A., Lancaster, L. J., Michaels, D., Pope, J. E., & Berry, J. M.
- Venue
- Anesthesia & Analgesia
- Published
- 2011-11
- Volume
- 113
- Issue
- 5
- Pages
- 1064-1067
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2792024824
- Cited by
- 22
- References
- 1
- FWCI
- 1.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.