Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 281

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Predicting the Limits of Cerebral Autoregulation During Cardiopulmonary Bypass

Open access
Joshi, Brijen, Ono, Masahiro, Brown, Charles, Brady, Kenneth, Easley, R. Blaine, Yenokyan, Gayane, Gottesman, Rebecca F., Hogue, Charles W.·2012·Anesthesia & Analgesia

Abstract

BACKGROUND: Mean arterial blood pressure (MAP) targets are empirically chosen during cardiopulmonary bypass (CPB). We have previously shown that near-infrared spectroscopy (NIRS) can be used clinically for monitoring cerebral blood flow autoregulation. The hypothesis of this study was that real-time autoregulation monitoring using NIRS-based methods is more accurate for delineating the MAP at the lower limit of autoregulation (LLA) during CPB than empiric determinations based on age, preoperative history, and preoperative blood pressure. METHODS: Two hundred thirty-two patients undergoing coronary artery bypass graft and/or valve surgery with CPB underwent transcranial Doppler monitoring of the middle cerebral arteries and NIRS monitoring. A continuous, moving Pearson correlation coefficient was calculated between MAP and cerebral blood flow velocity and between MAP and NIRS data to generate mean velocity index and cerebral oximeter index. When autoregulated, there is no correlation between cerebral blood flow and MAP (i.e., mean velocity and cerebral oximetry indices approach 0); when MAP is below the LLA, mean velocity and cerebral oximetry indices approach 1. The LLA was defined as the MAP at which mean velocity index increased with declining MAP to ≥ 0.4. Linear regression was performed to assess the relation between preoperative systolic blood pressure, MAP, MAP in 10% decrements from baseline, and average cerebral oximetry index with MAP at the LLA. RESULTS: The MAP at the LLA was 66 mm Hg (95% prediction interval, 43 to 90 mm Hg) for the 225 patients in which this limit was observed. There was no relationship between preoperative MAP and the LLA (P = 0.829) after adjusting for age, gender, prior stroke, diabetes, and hypertension, but a cerebral oximetry index value of >0.5 was associated with the LLA (P = 0.022). The LLA could be identified with cerebral oximetry index in 219 (94.4%) patients. The mean difference in the LLA for mean velocity index versus cerebral oximetry index was -0.2 ± 10.2 mm Hg (95% CI, -1.5 to 1.2 mm Hg). Preoperative systolic blood pressure was associated with a higher LLA (P = 0.046) but only for those with systolic blood pressure ≤ 160 mm Hg. CONCLUSIONS: There is a wide range of MAP at the LLA in patients during CPB, making estimation of this target difficult. Real-time monitoring of autoregulation with cerebral oximetry index may provide a more rational means for individualizing MAP during CPB.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/ane.0b013e31823d292a

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 281

Metadata

Authors
Joshi, B., Ono, M., Brown, C., Brady, K., Easley, R. B., Yenokyan, G., Gottesman, R. F., & Hogue, C. W.
Venue
Anesthesia & Analgesia
Published
2012-03
Volume
114
Issue
3
Pages
503-510
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2098001175
Cited by
281
References
25
FWCI
14.16
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Predicting the Limits of Cerebral Autoregulation During Cardiopulmonary Bypass. https://app.cochat.ai/papers/10.1213/ane.0b013e31823d292a
The paper
Joshi, B., Ono, M., Brown, C., Brady, K., Easley, R. B., Yenokyan, G., Gottesman, R. F., & Hogue, C. W. (2012). Predicting the Limits of Cerebral Autoregulation During Cardiopulmonary Bypass. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0b013e31823d292a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.