Abstract
BACKGROUND: For most items used in operating rooms, it is unclear whether reusable items are environmentally and financially advantageous in comparison with single-use variants. We examined the life cycles of reusable and single-use central venous catheter kits used to aid the insertion of single-use, central venous catheters in operating rooms. We did not examine the actual disposable catheter sets themselves. We assessed the entire financial and environmental costs for the kits, including the influence of the energy source used for sterilization. METHODS: For the reusable central venous catheter kit, we performed a "time-in-motion" study to determine the labor costs and measured the energy and water consumption for cleaning and sterilization at Western Health, Melbourne, Australia. For the majority of the inputs for the single-use kit, we relied upon industry and inventory-sourced databases. We modeled the life cycles of the reusable and single-use central venous catheter kits with Monte Carlo analysis. RESULTS: Inclusive of labor, the reusable central venous catheter insertion kits cost $6.35 Australian ($A) (95% confidence interval [CI], $A5.89 to $A6.86), and the single-use kits cost $A8.65. For the reusable kit, CO(2) emissions were 1211 g (95% CI, 1099 to 1323 g) and for the single-use kit 407 g (95% CI, 379 to 442 g). Water use was 27.7 L (95% CI, 27.0 to 28.6 l) for the reusable kit and 2.5 L (95% CI, 2.1 to 2.9 l) for the single-use kit. For the reusable kit, sterilization had the greatest environmental cost, and for the single-use kit, the manufacture of plastic and metal components had the largest environmental costs. Different sources of electricity to make the reusable kits patient-ready again affected the CO(2) emissions: electricity from hospital gas cogeneration resulted in 436 g CO(2) (95% CI, 410 to 473 g CO(2)), from the United States electricity grid 764 g CO(2) (95% CI, 509 to 1174 g CO(2)), and from the European electricity grid 572 g (95% CI, 470 to 713 g CO(2)). CONCLUSIONS: Inclusive of labor, the reusable central venous catheter insertion kits were less expensive than were the single-use kits. For our hospital, which uses brown coal-sourced electricity, the environmental costs of the reusable kit were considerably greater than those of the single-use kit. Efforts to reduce the environmental footprint of reusable items should be directed towards decreasing the water and energy consumed in cleaning and sterilization. The source of hospital electricity significantly alters the relative environmental effects of reusable items.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In Australia, Davis et al. found that reusable ureteroscopes are marginally more carbon intensive than single-use equivalents, a finding that is influenced by the predominant use of coal-based electricity in Australia.(47)”
From The Carbon Footprint of Surgical Operations (2020) · cites this paper as [47]
In the citing paper
“a finding that is influenced by the predominant use of coal-based electricity in Australia.(47)”
From The Carbon Footprint of Surgical Operations (2020) · cites this paper as [47]
Citations
Cites
The ecoinvent Database: Overview and Methodological Framework (7 pp)
Frischknecht, R., Jungbluth, N., Althaus, H.-J., Doka, G., Dones, R., Heck, T., Hellweg, S., Hischier, R., Nemecek, T., Rebitzer, G., et al. (2005) · The International Journal of Life Cycle Assessment · doi:10.1065/lca2004.10.181.1 · Cited by 1,114
Estimate of the carbon footprint of the US health care sector
Chung, J. W., & Meltzer, D. O. (2009) · JAMA · doi:10.1001/jama.2009.1610 · Cited by 415 · cited 1×
“Approximately 8% of the total CO2 emissions from the United States arise from the health care sector.(5) The manu-”
BackgroundAnalyses of the recycling potential of medical plastic wastes
Lee, B.-K., Ellenbecker, M. J., & Moure-Eraso, R. (2002) · Waste Management · doi:10.1016/s0956-053x(02)00006-5 · Cited by 230
Life cycle costing in LCM: ambitions, opportunities, and limitations: Discussing a framework
Rebitzer, G., & Hunkeler, D. (2003) · The International Journal of Life Cycle Assessment · doi:10.1007/bf02978913 · Cited by 200 · cited 1×
“determining the financial and environmental costs of a product over its entire life.(13,14) There are few published life”
BackgroundMulti-user test of the data quality matrix for product life cycle inventory data
Weidema, B. P. (1998) · The International Journal of Life Cycle Assessment · doi:10.1007/bf02979832 · Cited by 167 · cited 1×
“We used a Monte Carlo simulation to calculate the median and 95% confidence intervals (CIs).(22,23) For example, the CO2 emissions emanating from just the manufacture of stainless steel (an output) requires many inputs, such as the production and transport of iron, chromium, and other metals, each with their own varia…”
MethodThe Role of SETAC in the Development of LCA
Klöpffer, W. (2006) · The International Journal of Life Cycle Assessment · doi:10.1065/lca2006.04.019 · Cited by 162
The Financial and Environmental Costs of Reusable and Single-Use Plastic Anaesthetic Drug Trays
McGain, F., McAlister, S., McGavin, A., & Story, D. (2010) · Anaesthesia and Intensive Care · doi:10.1177/0310057x1003800320 · Cited by 114 · cited 1×
“were both environmentally and financially advantageous to single-use trays.(19) Drug trays, however, do not require”
BackgroundSelf-citationTieszen, M. (1992) · JAMA · doi:10.1001/jama.267.20.2765 · Cited by 109
Hutchins, D. C. J., & White, S. M. (2009) · BMJ · doi:10.1136/bmj.b609 · Cited by 106
Adler, S., Scherrer, M., Rückauer, K. D., & Daschner, F. D. (2004) · Surgical Endoscopy · doi:10.1007/s00464-003-9232-4 · Cited by 103
Cited by
Items 101–146 of 146
Reducing plastic in single-use central line insertion packs: A mixed methods observational study
Seville, A. R., Kazda, L., McAlister, S., Pickles, K. M., & Bell, K. (2025) · Anaesthesia and Intensive Care · doi:10.1177/0310057x251358276 · Cited by 4
Self-citationA new heuristic framework for estimating indirect (Scope 3) emissions of large organizations
Sawant, V., Wang, K., Tong, V., Fendler, Z., Krishnamoorthy, B., Gandhi, S., & Rajagopal, D. (2025) · Scientific Reports · doi:10.1038/s41598-025-17902-5 · Cited by 4
Environmentally responsible use of hospital infusion systems: a systematic review of the literature
Martin, E., Négrier, L., Lallemant, F., Odou, P., Masse, M., & Décaudin, B. (2025) · European Journal of Hospital Pharmacy · doi:10.1136/ejhpharm-2025-004536 · Cited by 3
“19 35 According to Castilho et al , the reasons for wastage included a lack of awareness and knowledge of the costs incurred, a lack of experience among students (leading to prescription changes or greater use of materials), thoughtless and excessive use, and the unnecessary opening of materials in…”
InfluentialSustainable healthcare in action: Six practice changes that make a difference
Catling, C., Crevacore, C., Young, M., Varndell, W., Cornish, J., Sheppard-Law, S., & Moll, E. C. (2026) · Collegian Journal of the Royal College of Nursing Australia · doi:10.1016/j.colegn.2026.02.003 · Cited by 3
Sustainability in Respiratory Therapy: Revisiting Reusables
Branson, R. D., & Ring, B. J. (2024) · Respiratory Care · doi:10.4187/respcare.11857 · Cited by 3
“22 In the latter study, conducted in Australia, the use of brown-coal sourced electricity for cleaning and sterilization inflated the environmental consequences.”
Reducing waste from single-use procedure packs in hospitals: A scoping review
Seville, A. R., Bell, K. J., Pickles, K. M., McAlister, S., Colagiuri, P., & Kazda, L. (2026) · Anaesthesia and Intensive Care · doi:10.1177/0310057x251374693 · Cited by 5
“28, 31,32 A audit study found differences of up”
InfluentialSelf-citationSowa, P. M., Fooken, J., McGowan, K., & Birch, S. (2022) · Community Dentistry And Oral Epidemiology · doi:10.1111/cdoe.12764 · Cited by 4
Response to ‘Healthcare and ecological economics at a crossroads'
McGain, F., Story, D., Lim, T., & McAlister, S. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex366 · Cited by 3
Self-citationA Comparative Carbon Footprint and Cost Analysis of Uterine Manipulators for Hysterectomy
Melnyk, A. I., Cano, N. S. D. S. L., Clark, S. G., Bilec, M. M., & Artsen, A. M. (2025) · Obstetrics and Gynecology · doi:10.1097/aog.0000000000005949 · Cited by 2
Davies, J. F., Hu, E. P., Best, S., & McGain, F. (2026) · Anaesthesia and Intensive Care · doi:10.1177/0310057x261428146 · Cited by 2
Self-citationGreve, P. J. W., Rahimi, M., Daams, F. D., Greve, J. W. M., Bonjer, H. J., Horeman, T., & Schijven, M. P. (2026) · Surgical Endoscopy · doi:10.1007/s00464-026-12765-x · Cited by 2
“Conversely, reusable instruments, although reducing waste, require resources for cleaning and sterilization, which can contribute to environmental pollution through water use and chemical discharges [12, 13].”
Byrne, C., Pley, C., Schorscher, P., Brandon, Z., Gatumbu, P., Mallinson, C., & Vaghela, M. (2023) · Future Healthcare Journal · doi:10.7861/fhj.2022-0129 · Cited by 2
Sustainable Solutions for Medical Devices and Services
Unger, S. R. (2015) · Cited by 2
Ökologische Nachhaltigkeit in der Intensivmedizin
Schuster, M., & Bein, T. (2024) · Die Anaesthesiologie · doi:10.1007/s00101-024-01485-3 · Cited by 1
Theatre waste production and the carbon emissions from tonsillectomy surgery
Cavada, M. N., McAlister, S., Sacks, R., & Birman, C. S. (2026) · Australian Journal of Otolaryngology · doi:10.21037/ajo-25-25 · Cited by 1
Self-citationJerin, A., Mahmud, M. A. P., Michalczyk, A., & Kouzani, A. Z. (2026) · International Journal of Environmental Science and Technology · doi:10.1007/s13762-026-07117-0 · Cited by 1
“Data for LCA are sourced from a combination of literature sources (McGain et al. 2017, 2012; Stripple et al. 2008; Sherman et al. 2018; Thiel et al. 2015) and public databases, with the ecoinvent database (Ecoinvent 2024) serving as a primary resource due to its reliability and extensive coverage.”
Nikolopoulou, M.-Z., Avgoulea, M., Papathanassiou, E., & Θεοδωρακοπούλου, Μ. (2026) · Green Health · doi:10.3390/greenhealth2010007 · Cited by 1
“Reusable central venous catheter kits, surgical gowns, and cleanroom garments reduce energy use, greenhouse gas emissions, water consumption, and solid waste compared with single-use equivalents, particularly when sterilization employs low-carbon or renewable energy sources [27].”
Australian Research on Climate Change and Health Interventions: A Systematic Mapping Review
Vardoulakis, S., Kazda, L., Haddock, R., Barratt, A. L., McGain, F., Wangdi, K., Okokon, E. O., Oyarce, D. A. E., Indu, G., Goodman, N. B., et al. (2026) · The Medical Journal of Australia · doi:10.5694/mja2.70165 · Cited by 1
Self-citationMandarano, R., Spadaro, S., Azzolina, D., Commissari, R., Lionetti, V., Monzani, R., Romagnoli, S., Sorbello, M., Violini, A., Bignami, E., et al. (2026) · Journal of Anesthesia Analgesia and Critical Care · doi:10.1186/s44158-026-00379-7 · Cited by 1
Environmental impact of total hip replacements: a life cycle assessment study
Rasmussen, A. R., Brorson, S., Dudka, K. M., & Hauschild, M. Z. (2026) · BMJ Open · doi:10.1136/bmjopen-2025-109563 · Cited by 1
Environmental impact of peripheral venous cannulation: comparison between methods
Bei, M., McAlister, S., O'Shea, C., Davies, R., & McGain, F. (2026) · British Journal of Anaesthesia · doi:10.1016/j.bja.2026.03.040 · Cited by 1
Self-citationEnvironmental sustainability evidence in critical care medicine: a scoping review
Balan, M., Bodley, T. F., Heybati, K., Deng, J., Gaetani, M., Maratta, C., Swab, M., Burns, K. E. A., & Murthy, S. (2026) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-026-03142-2 · Cited by 3
“94,95 In this review, we identi fi ed a wide range of effective interventions varying in feasibility and impact, many of which have been proposed by others.”
Evaluating the environmental performance of service sector industries
Shrake, S. O. (2012) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 2
Kara, Ö., & Ak, E. S. (2025) · Mersin Üniversitesi Tıp Fakültesi Lokman Hekim Tıp Tarihi ve Folklorik Tıp Dergisi · doi:10.31020/mutftd.1549201 · Cited by 2
Sanchez, S. A. (2023) · Digital Repository Service (Northeastern University) · doi:10.17760/d20487599
Valenzi, N. (2023) · Western Journal of Emergency Medicine · doi:10.5811/westjem.62602
CO2-Fußabdruck der Intensivmedizin – „let’s go green“
Bein, T. (2024) · Wiener klinisches Magazin · doi:10.1007/s00740-023-00516-w
Ramos, T. M., Eriksen, O., Cimpan, C., Khoshnevisan, B., Christensen, T. B., Hooge, A., & Syberg, K. (2024) · Research Square · doi:10.21203/rs.3.rs-4193318/v1
Reducing the Environmental Impact of Your Practice
Waberski, A. T., & Pestieau, S. R. (2024) · Oxford University Press eBooks · doi:10.1093/med/9780197655979.003.0024
An Innovative Strategy for Sustainability Assurance in Orthopedic Surgery
Moldovan, F., & Moldovan, L. (2025) · Medical Sciences · doi:10.3390/medsci13030093
“There are opinions, like MacGain [55,58], which show that CO 2 emissions from sterilization processes depend on the electricity source of the hospital.”
Thöne, M. (2025) · Globale Ziele für nachhaltige Entwicklung. · doi:10.1007/978-3-662-70588-9_22
Hernández, M. I., Juliá, J. B., Fernández, R. G., González-Martín, S., Tornero, S. L., Morente, E. M., Cárdenas, Y. M., Blanco, J. R., Domínguez, R. R., Leiguez, J. J. S., et al. (2025) · Nursing in Critical Care · doi:10.1111/nicc.70165
“Although recycling remains a visible and accessible intervention within clinical settings, it is essential to recognise that its impact on reducing health care's overall carbon footprint is limited [11–13].”
Torres-Ruiz, M. F., Aguirre-Olmedo, I., Ortiz, A. C. E., Lamothe-Ale, G., Méndez-Villanueva, M. T., Ayala-Rabadán, J., Herrera, M. N. G., Reyes-García, M. A., Sánchez-Cano, D. X., & Murguía, E. B. (2025) · Cirujano General · doi:10.35366/121423
Sirohiya, P. (2025) · Anaesthesia and Intensive Care · doi:10.1177/0310057x251387732
Sustainable Solutions for Medical Devices and Services
Unger, S. R. (2015) · Arizona State University Library Digital Repository (Arizona State University) · Cited by 2
Sustainable solutions for respiratory and airway biomedical devices
Webb, C. (2024) · Brunel University Research Archive (BURA) (Brunel University London) · Cited by 1
van Dolderen, D. C. (2023) · Research Repository (Delft University of Technology) · Cited by 1
Faringial hava olu: Anatomisi ve diş hekimliği açısından önemi
ERÇALIK YALÇINKAYA, Ş. (2022) · Dspace Repository (Marmara Üniversitesi)
Seville, A. R., Kazda, L., McAlister, S., & Bell, K. J. (2025) · Anaesthesia and Intensive Care · doi:10.1177/0310057x251387729
Self-citationGreen transplant: A scoping review of sustainability challenges and opportunities in transplantation
Emmanouilidou, A., Avramidou, E., Karageorgos, F. F., Anastasopoulos, N.-A., Papalois, V. E., & Tsoulfas, G. (2026) · World Journal of Transplantation · doi:10.5500/wjt.v16.i1.108837 · Cited by 1
Measuring the carbon cost of hand surgery: A single-centre observational study
Leijonberg, L., Hindocha, S., & Maheshwari, K. (2026) · Journal of Hand and Microsurgery · doi:10.1016/j.jham.2026.100448
Contribution of hospitals and clinical services to global warming: a scoping systematic review
Merino, W., Cárcamo-Fuentes, C., Peña, M., Zalej, B., Rodríguez-García, J., Gottschalk-Cuevas, M. D. L. Á., Rubilar, F., & Martínez‐Zapata, M. J. (2026) · Frontiers in Public Health · doi:10.3389/fpubh.2026.1778269
The NHS carbon footprint of paediatric tonsillectomies
Turner, O., Elhag, S., Ismail‐Koch, H., & Aarvold, A. (2026) · Annals of The Royal College of Surgeons of England · doi:10.1308/rcsann.2025.0102
Zazay, I., & Burmeister, J. (2026) · Anaesthesia and Intensive Care · doi:10.1177/0310057x261415904
“McGain et al. 2 showed that reusable central-line kits emitted more carbon where coal-dominant energy grids prevail.”
Choosing Wisely Canada climate-conscious recommendations for critical care medicine
Balan, M., Bodley, T. F., Montazeripouragha, A., Baharmand, I., Yu, A. C. M., Burns, K. E. A., Murthy, S., for the Canadian Critical Care Society (CCCS) and on behalf of the CCCS Choosing Wisely Canada Climate-Conscious Recommendations Working Group, Allard, K., Astell, A., et al. (2026) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-026-03148-w
“50,51 As such, the engagement of waste management and environmental services is of utmost importance in considering switches from single-use to reusable equipment.”
Chanchai, W., Chitrachulrattanamanee, S., & Sukaval, K. (2026) · The Journal of Chulabhorn Royal Academy
Metadata
- Authors
- McGain, F., McAlister, S., McGavin, A., & Story, D.
- Affiliations
- Western Health (AU)
- The University of Melbourne (AU)
- Corresponding author
- McGain, Forbes
- Venue
- Anesthesia & Analgesia
- Published
- 2012-05
- Volume
- 114
- Issue
- 5
- Pages
- 1073-1080
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2030366116
- Cited by
- 140
- References
- 21
- Citations by year
- 2026: 20 · 2025: 14 · 2024: 13 · 2023: 24 · 2022: 23 · 2021: 13 · 2020: 10 · 2019: 4 · 2018: 3 · 2017: 3 · 2016: 7 · 2015: 1 · 2014: 3 · 2013: 1 · 2012: 1
- FWCI
- 1.59
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Anesthesia & Analgesia (publishedVersion, public-domain)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Environmental Engineering › Environmental Impact and Sustainability
- Life Sciences › Immunology and Microbiology › Microbiology › Medical Device Sterilization and Disinfection
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
- Keywords
- reusable medical devices, single-use medical devices, operating room equipment, CO2 emissions, water consumption, cost comparison, labor costs, environmental impact of medical devices, Monte Carlo simulation
- MeSH terms
- Carbon Dioxide, Catheterization, Central Venous, Computer Simulation, Conservation of Energy Resources, Costs and Cost Analysis, Disposable Equipment, Electricity, Environmental Pollution, Medical Waste, Monte Carlo Method, Stainless Steel, Sterilization, Victoria, Water, Water Pollution, Chemical, Models, Statistical, Equipment Reuse, Catheters
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.