Managing Fresh Gas Flow to Reduce Environmental Contamination
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Anesthetic drugs have the potential to contribute to global warming. There is some debate about the overall impact of anesthetic drugs relative to carbon dioxide, but there is no question that practice patterns can limit the degree of environmental contamination. In particular, careful attention to managing fresh gas flow can use anesthetic drugs more efficiently--reducing waste while achieving the same effect on the patient. The environmental impact of a single case may be minimal, but when compounded over an entire career, the manner in which fresh gas flow is managed by each individual practitioner can make a significant difference in the volume of anesthetic gases released into the atmosphere. The maintenance phase of anesthesia is the best opportunity to reduce fresh gas flow because circuit gas concentrations are relatively stable and it is often the longest phase of the procedure. There are, however, methods for managing fresh gas flow during induction and emergence that can reduce the amount of wasted anesthetic vapor. This article provides background information and discusses strategies for managing fresh gas flow during each phase of anesthesia with the goal of reducing waste when using a circle anesthesia system. Monitoring oxygen and anesthetic gas concentrations is essential to implementing these strategies safely and effectively. Future technological advances in anesthetic delivery systems are needed to make it less challenging to manage fresh gas flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global Warming Potential of Inhaled Anesthetics: Application to Clinical Use
Ryan, S. M., & Nielsen, C. J. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181e058d7 · Cited by 340 · cited 1×
“thetic gases and vapors that leave the circuit through the scavenging system.(2,3) The goal of this article is to de-”
Background
Cited by
Environmental sustainability in anaesthesia and critical care
McGain, F., Muret, J., Lawson, C., & Sherman, J. D. (2020) · British Journal of Anaesthesia · doi:10.1016/j.bja.2020.06.055 · Cited by 455
Atmospheric science, anaesthesia, and the environment
Campbell, M., & Pierce, J. M. T. (2015) · BJA Education · doi:10.1093/bjaceaccp/mku033 · Cited by 103
Financial and Environmental Costs of Manual versus Automated Control of End-Tidal Gas Concentrations
Tay, S., Weinberg, L., Peyton, P., Story, D., & Briedis, J. (2013) · Anaesthesia and Intensive Care · doi:10.1177/0310057x1304100116 · Cited by 73
Abandoning inhalational anaesthesia
White, S. M., & Shelton, C. L. (2020) · Anaesthesia · doi:10.1111/anae.14853 · Cited by 51
Metadata
- Authors
- Feldman, J. M.
- Venue
- Anesthesia & Analgesia
- Published
- 2012-05
- Volume
- 114
- Issue
- 5
- Pages
- 1093-1101
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W1997152969
- Cited by
- 107
- References
- 1
- FWCI
- 6.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.