Auditing Operating Room Recycling: A Management Case Report
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Much waste arises from operating rooms (ORs). We estimated the practical and financial feasibility of an OR recycling program, weighing all waste from 6 ORs in Melbourne, Australia. Over 1 week, 237 operations produced 1265 kg in total: general waste 570 kg (45%), infectious waste 410 kg (32%), and recyclables 285 kg (23%). The achieved recycling had no infectious contamination. The achieved recycling/potential recycling rate was 285 kg/517 kg (55%). The average waste disposal costs were similar for general waste and recycling. OR recycling rates of 20%-25% total waste were achievable without compromising infection control or financial constraints.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimate of the carbon footprint of the US health care sector
Chung, J. W., & Meltzer, D. O. (2009) · JAMA · doi:10.1001/jama.2009.1610 · Cited by 415
Analyses of the recycling potential of medical plastic wastes
Lee, B.-K., Ellenbecker, M. J., & Moure-Eraso, R. (2002) · Waste Management · doi:10.1016/s0956-053x(02)00006-5 · Cited by 230 · cited 2×
“(1) weight of general waste, infectious waste, and recyclables? (2) weight of infectious waste within all waste/recycling bins? (3) weight of recyclables remaining within the general and infectious waste? (4) ratio of achieved recycling/potential for further recycling? (5) financial cost in Australian dollars ($AUD, w…”
BackgroundEcological responsibility in anesthesia practice
Sherman, J. D., & Ryan, S. (2010) · International Anesthesiology Clinics · doi:10.1097/aia.0b013e3181ea7587 · Cited by 67
Cited by
Environmental sustainability in anaesthesia and critical care
McGain, F., Muret, J., Lawson, C., & Sherman, J. D. (2020) · British Journal of Anaesthesia · doi:10.1016/j.bja.2020.06.055 · Cited by 455
Self-citationOperating room greening initiatives—The old, the new, and the way forward: A narrative review
Wyssusek, K. H., Keys, M. T., & van Zundert, A. A. J. (2019) · Waste Management & Research: The Journal for a Sustainable Circular Economy · doi:10.1177/0734242x18793937 · Cited by 217
Guetter, C. R., Williams, B. J., Slama, E., Arrington, A., Henry, M. C., Möller, M. G., Tuttle-Newhall, J. E., Stein, S., & Crandall, M. (2018) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2018.07.021 · Cited by 156
Carbon footprint of general, regional, and combined anesthesia for total knee replacements
McGain, F., Sheridan, N., Wickramarachchi, K., Yates, S., Chan, B., & McAlister, S. (2021) · Anesthesiology · doi:10.1097/aln.0000000000003967 · Cited by 144
“Some recycling was already occurring in the operating room (plastics/paper/cardboard).(7,32) Data were modeled in SimaPro-9 life cycle assessment software (PRé Consultants, The Netherlands).”
MethodSelf-citationOperating room waste: disposable supply utilization in neurosurgical procedures
Zygourakis, C. C., Yoon, S., Valencia, V., Boscardin, C., Moriates, C., Gonzales, R., & Lawton, M. T. (2017) · Journal of neurosurgery · doi:10.3171/2016.2.jns152442 · Cited by 137
Metadata
- Authors
- McGain, F., Jarosz, K. M., Nguyen, M. N. H. H., Bates, S., & O’Shea, C. J.
- Venue
- A & A Case Reports
- Published
- 2015-08
- Volume
- 5
- Issue
- 3
- Pages
- 47-50
- ISSN
- 2325-7237 (ISSN-L)
- OpenAlex
- W1017738131
- Cited by
- 83
- References
- 3
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Auditing Operating Room Recycling: A Management Case Report. https://app.cochat.ai/papers/10.1213/xaa.0000000000000097
- The paper
- McGain, F., Jarosz, K. M., Nguyen, M. N. H. H., Bates, S., & O’Shea, C. J. (2015). Auditing Operating Room Recycling: A Management Case Report. A & A Case Reports. https://doi.org/10.1213/xaa.0000000000000097
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.