Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 487

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Long-term Electrical Capsular Stimulation in Patients with Obsessive-Compulsive Disorder

Nuttin, Bart J., Gabriëls, Loes A., Cosyns, Paul R., Meyerson, Björn A., Andréewitch, Sergej, Sunaert, Stefan G., Maes, Alex F., Dupont, Patrick J., Gybels, Jan M., Gielen, Frans, Demeulemeester, Hilde G. · 2003 · Neurosurgery

Abstract

OBJECTIVE: Because of the irreversibility of lesioning procedures and their possible side effects, we studied the efficacy of replacing bilateral anterior capsulotomy with chronic electrical capsular stimulation in patients with severe, long-standing, treatment-resistant obsessive-compulsive disorder. METHODS: We stereotactically implanted quadripolar electrodes in both anterior limbs of the internal capsules into six patients with severe obsessive-compulsive disorder. Psychiatrists and psychologists performed a double-blind clinical assessment. A blinded random crossover design was used to assess four of those patients, who underwent continuous stimulation thereafter. RESULTS: The psychiatrist-rated Yale-Brown Obsessive Compulsive Scale score was lower in the stimulation-on condition (mean, 19.8 +/- 8.0) than in the postoperative stimulator-off condition (mean, 32.3 +/- 3.9), and this stimulation-induced effect was maintained for at least 21 months after surgery. The Clinical Global Severity score decreased from 5 (severe; standard deviation, 0) in the stimulation-off condition to 3.3 (moderate to moderate-severe; standard deviation, 0.96) in the stimulation-on condition. The Clinical Global Improvement scores were unchanged in one patient and much improved in the other three during stimulation. During the stimulation-off period, symptom severity approached baseline levels in the four patients. Bilateral stimulation led to increased signal on functional magnetic resonance imaging studies, especially in the pons. Digital subtraction analysis of preoperative [(18)F]2-fluoro-2-deoxy-d-glucose positron emission tomographic scans and positron emission tomographic scans obtained after 3 months of stimulation showed decreased frontal metabolism during stimulation. CONCLUSION: These observations indicate that capsular stimulation reduces core symptoms 21 months after surgery in patients with severe, long-standing, treatment-refractory obsessive-compulsive disorder. The stimulation elicited changes in regional brain activity as measured by functional magnetic resonance imaging and positron emission tomography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1227/01.neu.0000064565.49299.9a

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Cited by

See all 487

Metadata

Authors
Nuttin, B. J., Gabriëls, L. A., Cosyns, P. R., Meyerson, B. A., Andréewitch, S., Sunaert, S. G., Maes, A. F., Dupont, P. J., Gybels, J. M., Gielen, F., & Demeulemeester, H. G.
Venue
Neurosurgery
Published
2003-06
Volume
52
Issue
6
Pages
1263-1274
ISSN
0148-396X (ISSN-L)
OpenAlex
W2021492964
Cited by
487
References
30
FWCI
26.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Long-term Electrical Capsular Stimulation in Patients with Obsessive-Compulsive Disorder. https://app.cochat.ai/papers/10.1227/01.neu.0000064565.49299.9a
The paper
Nuttin, B. J., Gabriëls, L. A., Cosyns, P. R., Meyerson, B. A., Andréewitch, S., Sunaert, S. G., Maes, A. F., Dupont, P. J., Gybels, J. M., Gielen, F., & Demeulemeester, H. G. (2003). Long-term Electrical Capsular Stimulation in Patients with Obsessive-Compulsive Disorder. Neurosurgery. https://doi.org/10.1227/01.neu.0000064565.49299.9a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.