Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 364

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

ENDOVASCULAR OCCLUSION OF WIDE-NECKED ANEURYSMS WITH A NEW INTRACRANIAL MICROSTENT (NEUROFORM) AND DETACHABLE COILS

Benitez, Ronald P., Silva, Marco T., Klem, Jack, Veznedaroglu, Erol, Rosenwasser, Robert H.·2004·Neurosurgery

Abstract

OBJECTIVE: The long-term durability of the endovascular occlusion of cerebral aneurysms is one of the major factors limiting the more widespread use of this technique. Long-term occlusion of wide-necked aneurysms has improved with new assistive devices that seem to improve aneurysm occlusion while protecting the parent vessel. We report the use of a new intracranial stent--the Neuroform microstent--in the treatment of patients with wide-necked cerebral aneurysms. METHODS: Patients identified as harboring wide-necked intracranial aneurysms were evaluated for stent-assisted coiling. After appropriate anticoagulation was performed, depending on whether the aneurysm was ruptured or unruptured, the Neuroform stent was delivered across the neck of the aneurysm and deployed with a coil pusher. After stent placement, standard coil occlusion of the aneurysm was achieved in the majority of cases. RESULTS: Fifty-six patients were identified as having wide-necked intracranial aneurysms suitable for stent-assisted coiling. A total of 49 aneurysms in 48 patients were treated with this procedure. In eight cases, stent deployment failed. Forty-one of the aneurysms were initially stented, followed by coil placement. Six aneurysms were stented only, and one aneurysm was initially coiled, followed by stent placement. There were five deaths (8.9%), one of which occurred secondary to a stroke after the procedure (1.8%). Four patients (7%) experienced thromboembolic events, three of which were considered to have been secondary to the procedure (5.3%). In addition, there were two femoral pseudoaneurysms. The overall complication rate was 10.7%. Five patients were available for follow-up angiographic evaluation, and their cases are discussed. CONCLUSION: Intracranial stenting may overcome important technical limitations in current endovascular therapy by improving the occlusion of wide-necked aneurysms while protecting the parent vessel.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1227/01.neu.0000124484.87635.cd

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 364

Metadata

Authors
Benitez, R. P., Silva, M. T., Klem, J., Veznedaroglu, E., & Rosenwasser, R. H.
Venue
Neurosurgery
Published
2004-06
Volume
54
Issue
6
Pages
1359-1368
ISSN
  • 0148-396X (ISSN-L)
  • 1524-4040
OpenAlex
W2044313202
Cited by
364
References
14
FWCI
18.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ENDOVASCULAR OCCLUSION OF WIDE-NECKED ANEURYSMS WITH A NEW INTRACRANIAL MICROSTENT (NEUROFORM) AND DETACHABLE COILS. https://app.cochat.ai/papers/10.1227/01.neu.0000124484.87635.cd
The paper
Benitez, R. P., Silva, M. T., Klem, J., Veznedaroglu, E., & Rosenwasser, R. H. (2004). ENDOVASCULAR OCCLUSION OF WIDE-NECKED ANEURYSMS WITH A NEW INTRACRANIAL MICROSTENT (NEUROFORM) AND DETACHABLE COILS. Neurosurgery. https://doi.org/10.1227/01.neu.0000124484.87635.cd

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.