The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
ENDOVASCULAR OCCLUSION OF WIDE-NECKED ANEURYSMS WITH A NEW INTRACRANIAL MICROSTENT (NEUROFORM) AND DETACHABLE COILS
Abstract
OBJECTIVE: The long-term durability of the endovascular occlusion of cerebral aneurysms is one of the major factors limiting the more widespread use of this technique. Long-term occlusion of wide-necked aneurysms has improved with new assistive devices that seem to improve aneurysm occlusion while protecting the parent vessel. We report the use of a new intracranial stent--the Neuroform microstent--in the treatment of patients with wide-necked cerebral aneurysms. METHODS: Patients identified as harboring wide-necked intracranial aneurysms were evaluated for stent-assisted coiling. After appropriate anticoagulation was performed, depending on whether the aneurysm was ruptured or unruptured, the Neuroform stent was delivered across the neck of the aneurysm and deployed with a coil pusher. After stent placement, standard coil occlusion of the aneurysm was achieved in the majority of cases. RESULTS: Fifty-six patients were identified as having wide-necked intracranial aneurysms suitable for stent-assisted coiling. A total of 49 aneurysms in 48 patients were treated with this procedure. In eight cases, stent deployment failed. Forty-one of the aneurysms were initially stented, followed by coil placement. Six aneurysms were stented only, and one aneurysm was initially coiled, followed by stent placement. There were five deaths (8.9%), one of which occurred secondary to a stroke after the procedure (1.8%). Four patients (7%) experienced thromboembolic events, three of which were considered to have been secondary to the procedure (5.3%). In addition, there were two femoral pseudoaneurysms. The overall complication rate was 10.7%. Five patients were available for follow-up angiographic evaluation, and their cases are discussed. CONCLUSION: Intracranial stenting may overcome important technical limitations in current endovascular therapy by improving the occlusion of wide-necked aneurysms while protecting the parent vessel.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Treatment of Intracranial Aneurysms by Embolization with Coils: A Systematic Review
Brilstra, E. H., Rinkel, G. J. E., van der Graaf, Y., van Rooij, W. J. J., & Algra, A. (1999) · Stroke · doi:10.1161/01.str.30.2.470 · Cited by 491
Byrne, J. V., Sohn, M.-J., & Molyneux, A. J. (1999) · Journal of Neurosurgery · doi:10.3171/jns.1999.90.4.0656 · Cited by 485
Higashida, R. T., Smith, W., Gress, D., Urwin, R., Dowd, C. F., Balousek, P. A., & Halbach, V. V. (1997) · Journal of Neurosurgery · doi:10.3171/jns.1997.87.6.0944 · Cited by 444
Koivisto, T., Vanninen, R., Hurskainen, H., Saari, T., Hernesniemi, J., & Vapalahti, M. (2000) · Stroke · doi:10.1161/01.str.31.10.2369 · Cited by 393
Intracranial berry aneurysms: angiographic and clinical results after endovascular treatment.
Cognard, C., Weill, A., Castaings, L., Rey, A., & Moret, J. (1998) · Radiology · doi:10.1148/radiology.206.2.9457205 · Cited by 296
Eskridge, J. M., Song, J. K., & _, _. (1998) · Journal of Neurosurgery · doi:10.3171/jns.1998.89.1.0081 · Cited by 291
Selective endovascular treatment of 71 intracranial aneurysms with platinum coils
Casasco, A. E., Aymard, A., Gobin, Y. P., Houdart, E., Rogopoulos, A., George, B., Hodes, J. E., Cophignon, J., & Merland, J. J. (1993) · Journal of Neurosurgery · doi:10.3171/jns.1993.79.1.0003 · Cited by 233
Lempert, T. E., Malek, A. M., Halbach, V. V., Phatouros, C. C., Meyers, P. M., Dowd, C. F., & Higashida, R. T. (2000) · Stroke · doi:10.1161/01.str.31.1.100 · Cited by 152
C-Reactive Protein Levels and Viable Chlamydia pneumoniae in Carotid Artery Atherosclerosis
Johnston, S. C., Messina, L. M., Browner, W. S., Lawton, M. T., Morris, C., & Dean, D. (2001) · Stroke · doi:10.1161/hs1201.099631 · Cited by 141
Raftopoulos, C., Mathurin, P., Boscherini, D., Billa, R. F., Boven, M. V., & Hantson, P. E. (2000) · Journal of neurosurgery · doi:10.3171/jns.2000.93.2.0175 · Cited by 130
A comparison between endovascular and surgical management of basilar artery apex aneurysms
Gruber, D. P., Zimmerman, G. A., Tomsick, T. A., van Loveren, H. R., Link, M. J., & Tew, J. M. (1999) · Journal of neurosurgery · doi:10.3171/jns.1999.90.5.0868 · Cited by 127
Guglielmi, G. (1999) · Neurosurgery · doi:10.1097/00006123-199910000-00069 · Cited by 66
Malek, A. M., Higashida, R. T., Phatouros, C. C., Dowd, C. F., & Halbach, V. V. (1999) · Neurosurgery · doi:10.1097/00006123-199905000-00125 · Cited by 53
Cited by
The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms Trial
Nelson, P. K., Lylyk, P., Szikora, I., Wetzel, S. G., Wanke, I., & Fiorella, D. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2421 · Cited by 843
Piotin, M., Blanc, R., Spelle, L., Mounayer, C., Piantino, R., Schmidt, P. J., & Moret, J. (2010) · Stroke · doi:10.1161/strokeaha.109.558114 · Cited by 644
Chalouhi, N., Jabbour, P., Singhal, S., Drueding, R., Starke, R. M., Dalyai, R. T., Tjoumakaris, S., Gonzalez, L. F., Dumont, A. S., Rosenwasser, R., et al. (2013) · Stroke · doi:10.1161/strokeaha.111.000641 · Cited by 401
Self-citationThe NIH registry on use of the Wingspan stent for symptomatic70–99% intracranial arterial stenosis
Zaidat, O. O., Klucznik, R., Alexander, M. J., Chaloupka, J., Lutsep, H., Barnwell, S., Mawad, M., Lane, B., Lynn, M. J., & Chimowitz, M. (2008) · Neurology · doi:10.1212/01.wnl.0000306308.08229.a3 · Cited by 341
Naggara, O. N., White, P. M., Guilbert, F., Roy, D., Weill, A., & Raymond, J. (2010) · Radiology · doi:10.1148/radiol.10091982 · Cited by 304
Metadata
- Authors
- Benitez, R. P., Silva, M. T., Klem, J., Veznedaroglu, E., & Rosenwasser, R. H.
- Venue
- Neurosurgery
- Published
- 2004-06
- Volume
- 54
- Issue
- 6
- Pages
- 1359-1368
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2044313202
- Cited by
- 364
- References
- 14
- FWCI
- 18.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.