The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Usefulness of the Neuroform Stent for the Treatment of Cerebral Aneurysms: Results at Initial (3–6-mo) Follow-up
Abstract
OBJECTIVE: The Neuroform microstent, a flexible, self-expanding, nitinol stent specifically designed for use in the cerebral vasculature, became available in North America for aneurysm treatment in November 2002. The present report details our experience with the Neuroform stent over the past 2 years, with an emphasis on evolving treatment strategies and treatment durability at initial (3–6 mo) follow-up. METHODS: All patients included in this report were registered in a prospectively maintained database. We assessed the clinical history, indications for stent use, aneurysm dimensions, technical details of the procedures, degree of aneurysm occlusion, angiographic and clinical findings at follow-up, and complications. RESULTS: Over a 20-month period, 64 patients with 74 aneurysms were treated with 86 Neuroform stents. Of 64 patients, 16 (25%) were treated in the context of subarachnoid hemorrhage (8 acute, 7 subacute, 1 remote). Indications for stent use included broad aneurysm neck (n = 51 stents; average neck, 5.1 mm; aneurysm size, 8.2 mm), fusiform/dissecting morphology (n = 17), salvage/bailout for coils prolapsed into the parent vessel (n = 7), and giant aneurysm (n = 11). Sixty-one aneurysms were stented and coiled with complete or near complete (>95%) occlusion in 28 patients (45.9%) and partial occlusion (<95%) in 33 patients (54%). Follow-up angiographic (n = 43) or magnetic resonance angiographic (n = 5) data (average follow-up, 4.6 mo; median, 4 mo; range, 1.5–13 mo) for 48 aneurysms (46 patients) after stent-supported coil embolization demonstrated progressive thrombosis in 25 patients (52%), recanalization in 11 patients (23%) (8 of whom were retreated), and no change in 12 patients (25%). Follow-up angiography in 5 additional patients with dissecting aneurysms treated with stents alone demonstrated interval vascular remodeling with decreased aneurysm size in all patients. Delayed, severe, in-stent stenosis was observed in 3 patients, 1 of whom was symptomatic and required angioplasty and subsequently superficial temporal artery-to-middle cerebral artery bypass surgery. Using the second-generation Neuroform2 delivery system (n = 53), very few technical problems with stent delivery and deployment have been encountered (n = 2). CONCLUSION: The Neuroform stent facilitates adequate embolization of complex cerebral aneurysms, which would not otherwise be amenable to endovascular therapy. Initial follow-up data indicate favorable progressive thrombosis and recanalization rates for aneurysms after Neuroform stent-assisted embolization. These advantages of stenting were most evident for small aneurysms with wide necks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guglielmi Detachable Coil embolization of cerebral aneurysms: 11 years' experience
Murayama, Y., Nien, Y. L., Duckwiler, G., Gobin, Y. P., Jahan, R., Frazee, J., Martin, N., & Viñuela, F. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.98.5.0959 · Cited by 810
Preliminary Experience Using the Neuroform Stent for the Treatment of Cerebral Aneurysms
Fiorella, D., Albuquerque, F. C., Han, P., & McDougall, C. G. (2004) · Neurosurgery · doi:10.1227/01.neu.0000097194.35781.ea · Cited by 333
Self-citationHenkes, H. H., Bose, A., Felber, S. R., Miloslavski, E., Berg-Dammer, E., & Kühne, D. (2002) · Interventional Neuroradiology · doi:10.1177/159101990200800202 · Cited by 141
Pathophysiology of Cerebral Ischemia
Macdonald, R. L., & Stoodley, M. A. (1998) · Neurologia medico-chirurgica · doi:10.2176/nmc.38.1 · Cited by 106
Fiorella, D. J., Albuquerque, F. C., Han, P., & McDougall, C. G. (2004) · Neurosurgery · doi:10.1227/01.neu.0000119351.86658.1d · Cited by 74
Self-citationLee, J. I., Ko, J. K., Choi, B. K., & Choi, C. H. (2012) · Journal of Korean Neurosurgical Society · doi:10.3340/jkns.2012.51.6.370 · Cited by 67
Peter, K., Köhler, B., Straub, A., Ruef, J., Moser, M., Nordt, T. K., Olschewski, M., Ohman, M. E., Kübler, W., & Bode, C. (2000) · Circulation · doi:10.1161/01.cir.102.13.1490 · Cited by 55
Can we prevent in-stent restenosis?
Garza, L., Aude, Y. W., & Saucedo, J. F. (2002) · Current Opinion in Cardiology · doi:10.1097/00001573-200209000-00012 · Cited by 33
Cited by
Piotin, M., Blanc, R., Spelle, L., Mounayer, C., Piantino, R., Schmidt, P. J., & Moret, J. (2010) · Stroke · doi:10.1161/strokeaha.109.558114 · Cited by 644
Ferns, S. P., Sprengers, M. E. S., van Rooij, W. J., Rinkel, G. J. E., van Rijn, J. C., Bipat, S., Sluzewski, M., & Majoie, C. B. L. M. (2009) · Stroke · doi:10.1161/strokeaha.109.553099 · Cited by 455
Metadata
- Authors
- Fiorella, D., Albuquerque, F. C., Deshmukh, V. R., & McDougall, C. G.
- Venue
- Neurosurgery
- Published
- 2005-06-01
- Volume
- 56
- Issue
- 6
- Pages
- 1191-1202
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2049347141
- Cited by
- 309
- References
- 8
- FWCI
- 13.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Usefulness of the Neuroform Stent for the Treatment of Cerebral Aneurysms: Results at Initial (3–6-mo) Follow-up. https://app.cochat.ai/papers/10.1227/01.neu.0000159645.86823.af
- The paper
- Fiorella, D., Albuquerque, F. C., Deshmukh, V. R., & McDougall, C. G. (2005). Usefulness of the Neuroform Stent for the Treatment of Cerebral Aneurysms: Results at Initial (3–6-mo) Follow-up. Neurosurgery. https://doi.org/10.1227/01.neu.0000159645.86823.af
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.