The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Spinal Cord Stimulation Electrode Design: A Prospective, Randomized, Controlled Trial Comparing Percutaneous with Laminectomy Electrodes: Part II–Clinical Outcomes
Abstract
OBJECTIVE: Spinal cord stimulation, in use for more than 30 years, has evolved into an easily implemented technique involving percutaneous or laminectomy electrode placement. In a randomized comparison of four-contact percutaneous and four-contact insulated laminectomy electrodes placed at the same level in the dorsal, epidural midline, quantitative measures of stimulator performance revealed significant technical advantages for the laminectomy electrodes. Our prospective, randomized, controlled trial compares clinical results in these same patients. METHODS: Impartial third parties followed our series of 24 patients with failed back surgery syndrome to gather clinical outcome data. We defined “success” as at least 50% sustained relief of pain and patient satisfaction with the result of treatment. RESULTS: At a mean follow-up of 1.9 years, 10 of 12 patients receiving the laminectomy electrode and 5 of 12 patients receiving the percutaneous electrode reported a successful outcome (P < 0.05). Follow-up at a mean of 2.9 years showed that this result was maintained in 5 of 12 patients with the laminectomy electrode and 3 of 12 with the percutaneous electrode (not statistically significant). Many patients reported improvements in most activities of daily living, and loss of function was rare. In addition, 9 patients with laminectomy electrodes and 4 with percutaneous electrodes reducted or eliminated analgesic intake (P < 0.05), and 2 returned to work. No electrode migration was observed. CONCLUSION: Laminectomy electrode placement, although more invasive than percutaneous placement, yields significantly better clinical results in patients with failed back surgery syndrome at mean 1.9 years follow-up. In our small sample, however, the statistical significance of this advantage disappeared at mean 2.9 years follow-up.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The McGill Pain Questionnaire: Major properties and scoring methods
Melzack, R. (1975) · Pain · doi:10.1016/0304-3959(75)90044-5 · Cited by 6,845
The measurement of clinical pain intensity: a comparison of six methods
Jensen, M. P., Karoly, P., & Braver, S. (1986) · Pain · doi:10.1016/0304-3959(86)90228-9 · Cited by 3,275
Electrical inhibition of pain by stimulation of the dorsal columns: preliminary clinical report.
Shealy, C. N., Mortimer, J. T., & RESWICK, J. B. (1990) · PubMed · Cited by 1,237
Electrical Inhibition of Pain by Stimulation of the Dorsal Columns: Preliminary Clinical Report
SHEALY, C. N., MORTIMER, J. T., & RESWICK, J. B. (1967) · Anesthesia & Analgesia · doi:10.1213/00000539-196707000-00025 · Cited by 1,016
North, R. B., Kidd, D. H., Farrokhi, F., & Piantadosi, S. A. (2005) · Neurosurgery · doi:10.1227/01.neu.0000144839.65524.e0 · Cited by 926
Self-citationNonorganic Physical Signs in Low-Back Pain
WADDELL, G., McCULLOCH, J. A., KUMMEL, E., & VENNER, R. M. (1980) · Spine · doi:10.1097/00007632-198003000-00005 · Cited by 840
Spinal Cord Stimulation for Chronic, Intractable Pain
North, R. B., Kidd, D. H., Zahurak, M., James, C. S., & Long, D. M. (1993) · Neurosurgery · doi:10.1227/00006123-199303000-00008 · Cited by 496
Self-citationA spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415
Failed Back Surgery Syndrome: 5-Year Follow-Up in 102 Patients Undergoing Repeated Operation
North, R. B., Campbell, J. N., James, C. S., Conover-Walker, M. K., Wang, H., Piantadosi, S., Rybock, J. D., & Long, D. M. (1991) · Neurosurgery · doi:10.1227/00006123-199105000-00008 · Cited by 380
Self-citationSpinal cord stimulation for chronic, intractable pain: Superiority of “multi-channel” devices
North, R. B., Ewend, M. G., Lawton, M. T., & Piantadosi, S. (1991) · Pain · doi:10.1016/0304-3959(91)90125-h · Cited by 352
Self-citation
Cited by
Kumar, K., Hunter, G., & Demeria, D. (2006) · Neurosurgery · doi:10.1227/01.neu.0000192162.99567.96 · Cited by 488
Interventional management of neuropathic pain: NeuPSIG recommendations
Dworkin, R. H., O’Connor, A. B., Kent, J., Mackey, S. C., Raja, S. N., Stacey, B. R., Levy, R. M., Backonja, M., Baron, R., Harke, H., et al. (2013) · Pain · doi:10.1016/j.pain.2013.06.004 · Cited by 457
Electronics with shape actuation for minimally invasive spinal cord stimulation
Woodington, B. J., Curto, V. F., Yu, Y.-L., Martínez-Domínguez, H., Coles, L., Malliaras, G. G., Proctor, C. M., & Barone, D. G. (2021) · Science Advances · doi:10.1126/sciadv.abg7833 · Cited by 75
Neural Interface Devices: Spinal Cord Stimulation Technology
North, R. B. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922558 · Cited by 59
Self-citationA customizable multi-channel stimulator for cortical neuroprosthesis
Ferrandez, J. M., Liano, E., Bonomini, P., Martinez, J. J., Toledo, J., & Fernandez, E. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4353390 · Cited by 14
Metadata
- Authors
- North, R. B., Kidd, D. H., Petrucci, L., & Dorsi, M. J.
- Venue
- Neurosurgery
- Published
- 2005-11-01
- Volume
- 57
- Issue
- 5
- Pages
- 990-996
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2044631824
- Cited by
- 266
- References
- 44
- FWCI
- 11.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spinal Cord Stimulation Electrode Design: A Prospective, Randomized, Controlled Trial Comparing Percutaneous with Laminectomy Electrodes: Part II–Clinical Outcomes. https://app.cochat.ai/papers/10.1227/01.neu.0000180030.00167.b9
- The paper
- North, R. B., Kidd, D. H., Petrucci, L., & Dorsi, M. J. (2005). Spinal Cord Stimulation Electrode Design: A Prospective, Randomized, Controlled Trial Comparing Percutaneous with Laminectomy Electrodes: Part II–Clinical Outcomes. Neurosurgery. https://doi.org/10.1227/01.neu.0000180030.00167.b9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.