A customizable multi-channel stimulator for cortical neuroprosthesis
Abstract
A simple architecture for a fully customizable cortical stimulator is presented. The whole device uses a 3D penetrating multielectrode array, which will be implanted in primary visual cortex (V1), offering different signal amplitude and waveforms sets. The system has been proved for injecting current (charge) in a safe, secure and precise way during acute animal experimentation. The architecture is based on a transistor based current injection stage and a microprocessor circuit with programmable waveforms. The dynamic characteristic of the stimulator provide the possibility to adapt the current level to the different working electrodes and tissue impedances. The system is specific tailored for a cortical visual neuroprosthesis for the blind.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Cortical implants like the Utah Electrode Array and customized multi-channel stimulator for cortical visual neuroprosthesis can be used for blinds.
“Additionally, some cortical implants like the Utah Electrode Array and the customized multi-channel stimulator for a cortical visual neuroprosthesis can be used for blinds (Ferrandez et al., 2007).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Ferrandez et al., 2007
Cites
Perlmutter, J. S., & Mink, J. W. (2006) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.29.051605.112824 · Cited by 1,073 · see citing works
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881 · see citing works
Schmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672 · cited 1× · see citing works
“Electrical stimulation of the visual cortex produces localized visual perceptions called phosphenes [ 5 ] [6] [7].”
BackgroundNorth, R. B., Kidd, D. H., Petrucci, L., & Dorsi, M. J. (2005) · Neurosurgery · doi:10.1227/01.neu.0000180030.00167.b9 · Cited by 267 · see citing works
North, R. B., Kidd, D. H., Olin, J. C., & Sieracki, J. M. (2002) · Neurosurgery · doi:10.1097/00006123-200208000-00015 · Cited by 134 · see citing works
Cortical implants for the blind
Normann, R. A., Maynard, E. M., Guillory, K. S., & Warren, D. J. (1996) · IEEE Spectrum · doi:10.1109/6.490057 · Cited by 101 · see citing works
Loeb, G. E. (1990) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.13.030190.002041 · Cited by 82 · see citing works
To beat or not to beat: the history and development of heart pacemakers
Woollons, D. J. (1995) · Engineering Science and Education Journal · doi:10.1049/esej:19950604 · Cited by 29 · see citing works
A Multiplexed Current Source Portable Stimulator Architecture for a Visual Cortical Neuroprosthesis
Ferrández, J. M., Bonomini, M. P., & Fernández, E. (2005) · Lecture notes in computer science · doi:10.1007/11499220_32 · Cited by 3 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Górriz, J. M., Álvarez, I., Álvarez-Marquina, A., Arco, J. E., Atzmueller, M., Ballarini, F., Barakova, E. I., Bologna, G., Bonomini, P., Castellanos-Dominguez, G., et al. (2023) · Information Fusion · doi:10.1016/j.inffus.2023.101945 · Cited by 231 · see citing works
Self-citationLewis, P. M., Ackland, H. M., Lowery, A. J., & Rosenfeld, J. V. (2015) · Brain Research · doi:10.1016/j.brainres.2014.11.020 · Cited by 228 · see citing works
Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.
Ghafoor, U., Kim, S., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00059 · Cited by 88 · see citing works
“Additionally, some cortical implants like the Utah Electrode Array and the customized multi-channel stimulator for a cortical visual neuroprosthesis can be used for blinds (Ferrandez et al., 2007).”
Bionic eye review - An update.
Nowik, K., Langwińska-Wośko, E., Skopiński, P., Nowik, K. E., & Szaflik, J. P. (2020) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2020.05.041 · Cited by 49 · see citing works
Microstimulation-evoked neural responses in visual cortex are depth dependent
Allison-Walker, T., Hagan, M. A., Price, N. S. C., & Wong, Y. T. (2021) · Brain stimulation · doi:10.1016/j.brs.2021.04.020 · Cited by 22 · see citing works
Central nervous system microstimulation: Towards selective micro-neuromodulation
Urdaneta, M. E., Koivuniemi, A. S., & Otto, K. J. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.09.012 · Cited by 16 · see citing works
Menon, A., & Vijayavenkataraman, S. (2022) · Artificial Organs · doi:10.1111/aor.14241 · Cited by 11 · see citing works
QRS-T Angle as a Biomarker for LBBB Strict Diagnose
Ordóñez, B. D. C. M., Vicente, J. M. F., & Bonomini, M. P. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-06242-1_58 · Cited by 3 · see citing works
Modeling and Simulations in Time Domain of a Stimulation Set-up for Cortical Applications
Schweigmann, M., Kirchhoff, F., & Koch, K. P. (2016) · European Journal of Translational Myology · doi:10.4081/ejtm.2016.6017 · Cited by 2 · see citing works
Huq, M., Garrigós, J., Martínez, J. J., Ferrandez, J., & Fernández, E. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-06242-1_63 · Cited by 1 · see citing works
Self-citationCurrent Advances in the Design of Retinal and Cortical Visual Prostheses
Bareket, L., Barriga‐Rivera, A., Rosenfeld, J. V., Lovell, N. H., & Suaning, G. J. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812539-7.00005-2
Automatic Left Bundle Branch Block Diagnose Using a 2-D Convolutional Network
Wood, A., Cerrato, M., & Bonomini, M. P. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-06242-1_57
Ordóñez, B. D. C. M., Garrigós, J., Martínez, J. J., Vicente, J. M. F., Ingallina, F., & Bonomini, M. P. (2026) · Integrated Computer-Aided Engineering · doi:10.1177/10692509261417117
- Authors
- Ferrandez, J. M., Liano, E., Bonomini, P., Martinez, J. J., Toledo, J., & Fernandez, E.
- Affiliations
- Universitat de Miguel Hernández d'Elx (ES)
- Universidad Politécnica de Cartagena (ES)
- Venue
- 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2007-08
- Volume
- 2007
- Pages
- 4707-4710
- ISSN
- 1557-170X (ISSN-L)
- OpenAlex
- W2125688826
- Cited by
- 14
- References
- 9
- Citations by year
- 2026: 1 · 2023: 1 · 2022: 4 · 2021: 1 · 2020: 1 · 2018: 1 · 2017: 2 · 2016: 1 · 2015: 1 · 2014: 1
- FWCI
- 0.00
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Conference proceedings (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- cortical stimulation, neural prostheses, visual prosthesis, microelectrode arrays, primary visual cortex, current injection, microprocessor control, blind rehabilitation
- MeSH terms
- Brain Diseases, Cerebral Cortex, Electric Stimulation, Equipment Design, Humans, Microscopy, Electron
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review