CoChat

Comparing Noninvasive Dense Array and Intracranial Electroencephalography for Localization of Seizures

Holmes, Mark D., Tucker, Don M., Quiring, Jason M., Hakimian, Shahin, Miller, John W., Ojemann, Jeffrey G. · 2010 · Neurosurgery
Cited by 97

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To compare the localization of the seizure onset zone estimated from ictal recordings with high spatial resolution, 256-channel scalp dense array electroencephalographic video long-term monitoring (LTM) with the aid of source analysis with that obtained from subsequent intracranial ictal recordings. METHODS: Ten patients with medically refractory epilepsy, all surgical candidates, underwent intracranial LTM after standard noninvasive evaluation failed to provide adequate localizing information regarding ictal origins. Before invasive studies, all patients underwent dense array electroencephalographic LTM in which habitual clinical seizures were recorded for each patient. Source analysis was applied to ictal onsets. Intracranial electrode placement followed conventional guidelines, although the neurosurgeon was aware of the dense array electroencephalographic results. Patients ranged in age from 10 to 49 years (mean age, 24 y); 7 were male. Identified risk factors included closed head injury in 1 patient and childhood meningitis in another. No focal neurological signs were found in any patient. Magnetic resonance imaging findings were normal in 6 patients; 1 patient had cerebellar hypoplasia, 1 had right frontoparietal dysplasia, 1 had bilateral nonspecific white matter abnormalities, and 1 had bilateral cavernous angiomas. RESULTS: Ictal onsets, based on invasive recordings, were in the mesiotemporal lobe (3 patients), lateroparietal (2 patients), mesioparietal (1 patient), laterofrontal (1 patient), superolateral frontocentral (1 patient), frontopolar (1 patient), and posteroinferior temporo-occipital neocortex (1 patient). Dense array electroencephalography localized ictal onsets to the same region as intracranial monitoring in 8 of 10 cases; invasive studies disclosed an additional ictal focus in 2 of these patients. Surgical resections were based only on intracranial electroencephalographic findings. CONCLUSION: Dense array electroencephalography has the potential to assist in the noninvasive localization of epileptic seizures and to guide the placement of invasive electrodes for localizing seizure onset.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1227/01.neu.0000363721.06177.07

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 97

Metadata

Authors
Holmes, M. D., Tucker, D. M., Quiring, J. M., Hakimian, S., Miller, J. W., & Ojemann, J. G.
Venue
Neurosurgery
Published
2010-02
Volume
66
Issue
2
Pages
354-362
ISSN
0148-396X (ISSN-L)
OpenAlex
W2070202219
Cited by
97
References
2
FWCI
6.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparing Noninvasive Dense Array and Intracranial Electroencephalography for Localization of Seizures. https://app.cochat.ai/papers/10.1227/01.neu.0000363721.06177.07
The paper
Holmes, M. D., Tucker, D. M., Quiring, J. M., Hakimian, S., Miller, J. W., & Ojemann, J. G. (2010). Comparing Noninvasive Dense Array and Intracranial Electroencephalography for Localization of Seizures. Neurosurgery. https://doi.org/10.1227/01.neu.0000363721.06177.07

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.