Surgical Outcomes for Minimally Invasive vs Open Transforaminal Lumbar Interbody Fusion: An Updated Systematic Review and Meta-analysis
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Minimally invasive transforaminal lumbar interbody fusion (TLIF)-or MI-TLIF-has been increasing in prevalence compared with open TLIF (O-TLIF) procedures. The use of MI-TLIF is an evolving technique with conflicting reports in the literature about outcomes. OBJECTIVE: To investigate the impact of MI-TLIF in comparison with O-TLIF for early and late outcomes by using the Visual Analog Scale for back pain (VAS-back) and the Oswestry Disability Index (ODI). Secondary end points include blood loss, operative time, radiation exposure, length of stay, fusion rates, and complications between the 2 procedures. METHODS: During August 2014, a systematic literature search was performed identifying 987 articles. Of these, 30 met inclusion criteria. A random-effects meta-analysis was performed by using both pooled and subset analyses based on study type. RESULTS: Our meta-analysis demonstrated that MI-TLIF reduced blood loss (P < .001), length of stay (P < .001), and complications (P = .001) but increased radiation exposure (P < .001). No differences were found in fusion rate (P = .61) and operative time (P = .34). A decrease in late VAS-back scores was demonstrated for MI TLIF (P < .001), but no differences were found in early VAS-back, early ODI, and late ODI. CONCLUSION: MI-TLIF is associated with reduced blood loss, decreased length of stay, decreased complication rates, and increased radiation exposure. The rates of fusion and operative time are similar between MI-TLIF and O-TLIF. Differences in long-term outcomes in MI-TLIF vs O-TLIF are inconclusive and require more research, particularly in the form of large, multi-institutional prospective randomized controlled trials. ABBREVIATIONS: CI, confidence intervalMCID, minimal clinically important differenceMI-TLIF, minimally invasive transforaminal lumbar interbody fusionODI, Oswestry Disability IndexO-TLIF, open transforaminal lumbar interbody fusionVAS, Visual Analog Scale.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & The PRISMA Group (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000097 · Cited by 64,042 · cited 1×
“This study was conducted using the Assessment ofMultiple Systematic Reviews (AMSTAR)(19) and the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA).(20) No protocol or registration was needed for this study.”
MethodBias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552 · cited 2×
“The overall risk ratio was computed by using the method of DerSimonian and Laird.24 Publication bias (ie, assessment of bias across studies) was graphically evaluated by using a funnel plot.25-27 Statistical analyses were conducted using Review Manager (RevMan) Version 5.2 software (Copenhagen: The Nordic Cochrane Cen…”
MethodInfluential(2014) · Medical Entomology and Zoology · Cited by 17,633
Assessing the quality of reports of randomized clinical trials: Is blinding necessary?
Jadad, A. R., Moore, R. A., Carroll, D., Jenkinson, C., Reynolds, D. J. M., Gavaghan, D. J., & McQuay, H. J. (1996) · Controlled Clinical Trials · doi:10.1016/0197-2456(95)00134-4 · Cited by 17,582 · cited 2×
“The 1 randomized controlled trial(13) in this analysis was not blinded; therefore, it received 3 of 5 points using the Jadad criteria.(23) The Table provides a summary of the characteristics of the included studies.”
MethodDevelopment of AMSTAR: A measurement tool to assess the methodological quality of systematic reviews
Shea, B. J., Grimshaw, J. M., Wells, G. A., Boers, M., Andersson, N., Hamel, C., Porter, A. C., Tugwell, P., Moher, D., & Bouter, L. M. (2007) · BMC Medical Research Methodology · doi:10.1186/1471-2288-7-10 · Cited by 4,374
Funnel plots for detecting bias in meta-analysis
Sterne, J. A. C., & Egger, M. (2001) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(01)00377-8 · Cited by 3,779
Investigating and dealing with publication and other biases in meta-analysis
Sterne, J. A. C., Egger, M., & Smith, G. D. (2001) · BMJ · doi:10.1136/bmj.323.7304.101 · Cited by 2,225
Metadata
- Authors
- Khan, N. R., Clark, A. J., Lee, S. L., Venable, G. T., Rossi, N. B., & Foley, K. T.
- Venue
- Neurosurgery
- Published
- 2015-12
- Volume
- 77
- Issue
- 6
- Pages
- 847-874
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W978538398
- Cited by
- 196
- References
- 23
- FWCI
- 12.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Surgical Outcomes for Minimally Invasive vs Open Transforaminal Lumbar Interbody Fusion: An Updated Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.1227/neu.0000000000000913
- The paper
- Khan, N. R., Clark, A. J., Lee, S. L., Venable, G. T., Rossi, N. B., & Foley, K. T. (2015). Surgical Outcomes for Minimally Invasive vs Open Transforaminal Lumbar Interbody Fusion: An Updated Systematic Review and Meta-analysis. Neurosurgery. https://doi.org/10.1227/neu.0000000000000913
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.