CoChat

Qualitative Imaging of Adeno-Associated Virus Serotype 2–Human Aromatic L-Amino Acid Decarboxylase Gene Therapy in a Phase I Study for the Treatment of Parkinson Disease

Valles, Francisco, Fiandaca, Massimo S, Eberling, Jamie L, Starr, Philip A, Larson, Paul S, Christine, Chadwick W, Forsayeth, John, Richardson, R Mark, Su, Xiaomin, Aminoff, Michael J, Bankiewicz, Krystof S · 2010 · Neurosurgery
Cited by 71

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Putaminal convection-enhanced delivery (CED) of an adeno-associated virus serotype 2 (AAV2) vector, containing the human aromatic L-amino acid decarboxylase (hAADC) gene for the treatment of Parkinson disease (PD), has completed a phase I clinical trial. OBJECTIVE: To retrospectively analyze magnetic resonance imaging (MRI) and positron emission tomography (PET) data from the phase I trial, correlate those data with similar nonhuman primate (NHP) data, and present how such information may improve future PD gene therapy trials in preparation for the initiation of the phase II trial. METHODS: Ten patients with PD had been treated with bilateral MRI-guided putaminal infusions of AAV2-hAADC. MRI and PET scans were obtained at baseline (before vector administration) and at various intervals after treatment. Three normal adult NHPs received similar infusions into the thalamus. Imaging studies for both groups are presented, as well as hAADC immunohistochemistry for the NHPs. RESULTS: Early post-CED MRI confirmed the stereotactic targeting accuracy and revealed T2 hyperintensity around the distal cannula tracts, best seen within 4 hours of surgery. Coregistration of post-CED MRI and PET scans revealed increased PET uptake at the sites of T2 hyperintensity. Similar T2 hyperintensities in NHP MRI correlated with hAADC immunohistochemistry. CONCLUSION: Our analysis confirms the correct targeting of the CED cannula tracts within the target human putamen. Coregistration of MRI and PET confirms colocalization of T2 hyperintensities and increased PET uptake around the distal cannula tracts. Because PET uptake closely correlates with hAADC transgene expression and NHP data confirm this relationship between T2 hyperintensity and hAADC immunohistochemistry, we believe that T2-weighted MRI allows visualization of a significant part of the distribution volume of the hAADC gene therapy. Recommendations for future protocols based on these data are presented.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1227/neu.0b013e3181f53a5c

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Valles, F., Fiandaca, M. S., Eberling, J. L., Starr, P. A., Larson, P. S., Christine, C. W., Forsayeth, J., Richardson, R. M., Su, X., Aminoff, M. J., & Bankiewicz, K. S.
Venue
Neurosurgery
Published
2010-11
Volume
67
Issue
5
Pages
1377-1385
ISSN
0148-396X (ISSN-L)
OpenAlex
W2094327816
Cited by
71
References
3
FWCI
4.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.