Abstract

BACKGROUND: Deep brain stimulation (DBS) is commonly used in the treatment of movement disorders such as Parkinson disease (PD), dystonia, and other tremors. OBJECTIVE: To examine systematic errors in image-guided DBS electrode placement and to explore a calibration strategy for stereotactic targeting. METHODS: Pre- and postoperative stereotactic MR images were analyzed in 165 patients. The perpendicular error between planned target coordinates and electrode trajectory was calculated geometrically for all 312 DBS electrodes implanted. Improvement in motor unified PD rating scale III subscore was calculated for those patients with PD with at least 6 months of follow-up after bilateral subthalamic DBS. RESULTS: Mean (standard deviation) scalar error of all electrodes was 1.4(0.9) mm with a significant difference between left and right hemispheres. Targeting error was significantly higher for electrodes with coronal approach angle (ARC) ≥10° (P < .001). Mean vector error was X: -0.6, Y: -0.7, and Z: -0.4 mm (medial, posterior, and superior directions, respectively). Targeting error was significantly improved by using a systematic calibration strategy based on ARC and target hemisphere (mean: 0.6 mm, P < .001) for 47 electrodes implanted in 24 patients. Retrospective theoretical calibration for all 312 electrodes would have reduced the mean (standard deviation) scalar error from 1.4(0.9) mm to 0.9(0.5) mm (36% improvement). With calibration, 97% of all electrodes would be within 2 mm of the intended target as opposed to 81% before calibration. There was no significant correlation between the degree of error and clinical outcome from bilateral subthalamic nucleus DBS (R = 0.07). CONCLUSION: After calibration of a systematic targeting error an MR image-guided stereotactic approach would be expected to deliver 97% of all electrodes to within 2 mm of the intended target point with a single brain pass.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1227/neu.0b013e3181f7422a

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 110

Metadata

Authors
Holl, E. M., Petersen, E. A., Foltynie, T., Martinez-Torres, I., Limousin, P., Hariz, M. I., & Zrinzo, L.
Venue
Operative Neurosurgery
Published
2010-12
Volume
67
Issue
2 Suppl Operative
Pages
ons437-ons447
ISSN
2332-4252 (ISSN-L)
OpenAlex
W2022812130
Cited by
110
References
1
FWCI
3.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improving Targeting in Image-Guided Frame-Based Deep Brain Stimulation. https://app.cochat.ai/papers/10.1227/neu.0b013e3181f7422a
The paper
Holl, E. M., Petersen, E. A., Foltynie, T., Martinez-Torres, I., Limousin, P., Hariz, M. I., & Zrinzo, L. (2010). Improving Targeting in Image-Guided Frame-Based Deep Brain Stimulation. Operative Neurosurgery. https://doi.org/10.1227/neu.0b013e3181f7422a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.