CoChat

Intraoperative Computed Tomography for Deep Brain Stimulation Surgery: Technique and Accuracy Assessment

Shahlaie, Kiarash, Larson, Paul S, Starr, Philip A · 2011 · Operative Neurosurgery
Cited by 95

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The efficacy of deep brain stimulation (DBS) is highly dependent on the accuracy of lead placement. OBJECTIVE: To describe the use of intraoperative computed tomography (iCT) to confirm lead location before surgical closure and to study the accuracy of this technique. METHODS: Fifteen patients underwent awake microelectrode-guided DBS surgery in a stereotactic frame. A portable iCT scanner (Medtronic O-arm) was positioned around the patient's head throughout the procedure and was used to confirm lead location before fixation of the lead to the skull. Images were computationally fused with preoperative magnetic resonance imaging (MRI), and lead tip coordinates with respect to the midpoint of the anterior commissure-posterior commissure line were measured. Tip coordinates were compared with those obtained from postoperative MRI. RESULTS: iCT was integrated into standard frame-based microelectrode-guided DBS surgery with a minimal increase in surgical time or complexity. Technically adequate 2-dimensional and 3-dimensional images were obtained in all cases. Head positioning and fixation techniques that allow unobstructed imaging are described. Lead tip measurements on iCT fused with preoperative MRI were statistically indistinguishable from those obtained with postoperative MRI. CONCLUSION: iCT can be easily incorporated into standard DBS surgery, replaces the need for C-arm fluoroscopy, and provides accurate intraoperative 3-dimensional confirmation of electrode tip locations relative to preoperative images and surgical plans. iCT fused to preoperative MRI may obviate the need for routine postoperative MRI in DBS surgery. Technical nuances that must be mastered for the efficient use of iCT during DBS implantation are described.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1227/neu.0b013e31820781bc

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Shahlaie, K., Larson, P. S., & Starr, P. A.
Venue
Operative Neurosurgery
Published
2011-03
Volume
68
Issue
1 Suppl Operative
Pages
ons114-ons124
ISSN
2332-4252 (ISSN-L)
OpenAlex
W2017257734
Cited by
95
References
1
FWCI
4.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.