The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Preoperative Functional Mapping for Rolandic Brain Tumor Surgery: Comparison of Navigated Transcranial Magnetic Stimulation to Direct Cortical Stimulation
Abstract
BACKGROUND: Transcranial magnetic stimulation (TMS) is the only noninvasive method for presurgical stimulation mapping of cortical function. Recent technical advancements have significantly increased the focality and usability of the method. OBJECTIVE: To compare the accuracy of a 3-dimensional magnetic resonance imaging-navigated TMS system (nTMS) with the gold standard of direct cortical stimulation (DCS). METHODS: The primary motor areas of 20 patients with rolandic tumors were mapped preoperatively with nTMS at 110% of the individual resting motor threshold. Intraoperative DCS was available from 17 patients. The stimulus locations eliciting the largest electromyographic response in the target muscles ("hotspots") were determined for both methods. RESULTS: The nTMS and DCS hotspots were located on the same gyrus in all cases. The mean ± SEM distance between the nTMS and DCS hotspots was 7.83 ± 1.18 mm for the abductor pollicis brevis (APB) muscle (n = 15) and 7.07 ± 0.88 mm for the tibialis anterior muscle (n = 8). When a low number of DCS stimulations was performed, the distance between the nTMS and DCS hotspots increased substantially (r = -0.86 for APB). After the exclusion of the cases with < 15 DCS APB responses, the mean ± SEM distance between the hotspots was only 4.70 ± 1.09 mm for APB (n = 8). CONCLUSION: Peritumoral mapping of the motor cortex by nTMS agreed well with the gold standard of DCS. Thus, nTMS is a reliable tool for preoperative mapping of motor function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rossini, P. M., Barker, A. T., Berardelli, A., Caramia, M. D., Caruso, G., Cracco, R. Q., Dimitrijević, M. R., Hallett, M., Katayama, Y., Lücking, C. H., et al. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90029-9 · Cited by 3,030
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
Duffau, H. (2005) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2004.048520 · Cited by 589
Shared Neural Substrates Controlling Hand Movements in Human Motor Cortex
Sanes, J. N., Donoghue, J. P., Thangaraj, V., Edelman, R. R., & Warach, S. (1995) · Science · doi:10.1126/science.7792606 · Cited by 471
Picht, T., Mularski, S., Kuehn, B., Vajkoczy, P., Kombos, T., & Suess, O. (2009) · Operative Neurosurgery · doi:10.1227/01.neu.0000348009.22750.59 · Cited by 180
Self-citationFUNCTIONAL BRAIN MAPPING AND ITS APPLICATIONS TO NEUROSURGERY
Tharin, S., & Golby, A. (2007) · Operative Neurosurgery · doi:10.1227/01.neu.0000255386.95464.52 · Cited by 176
Krings, T., Buchbinder, B. R., Butler, W. E., Chiappa, K. H., Jiang, H., Rosen, B. R., & Cosgrove, G. R. (1997) · Neurosurgery · doi:10.1097/00006123-199712000-00016 · Cited by 133
The 3D topography of MEG source localization accuracy: effects of conductor model and noise
Tarkiainen, A., Liljeström, M., Seppä, M., & Salmelin, R. H. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00195-0 · Cited by 90
The role of functional magnetic resonance imaging in brain surgery
Rutten, G.-J. M., & Ramsey, N. F. (2010) · Neurosurgical FOCUS · doi:10.3171/2009.12.focus09251 · Cited by 83
Hannula, H., Ylioja, S., Pertovaara, A., Korvenoja, A., Ruohonen, J., Ilmoniemi, R. J., & Carlson, S. (2005) · Human Brain Mapping · doi:10.1002/hbm.20142 · Cited by 78
Self-citation
Cited by
Rossi, S., Antal, A., Bestmann, S., Bikson, M., Brewer, C., Brockmöller, J., Carpenter, L. L., Cincotta, M., Chen, R., Daskalakis, J. D., et al. (2021) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.10.003 · Cited by 1,573
Cerebral plasticity: windows of opportunity in the developing brain
Ismail, F. Y., Fatemi, A., & Johnston, M. V. (2017) · European Journal of Paediatric Neurology · doi:10.1016/j.ejpn.2016.07.007 · Cited by 572
Picht, T., Krieg, S. M., Sollmann, N., Rösler, J., Niraula, B., Neuvonen, T., Savolainen, P., Lioumis, P., Mäkelä, J. P., Deletis, V., et al. (2013) · Neurosurgery · doi:10.1227/neu.0b013e3182889e01 · Cited by 312
Self-citationFocused Ultrasound-mediated Non-invasive Brain Stimulation: Examination of Sonication Parameters
Kim, H., Chiu, A., Lee, S. D., Fischer, K., & Yoo, S.-S. (2014) · Brain Stimulation · doi:10.1016/j.brs.2014.06.011 · Cited by 304
Metadata
- Authors
- Picht, T., Schmidt, S., Brandt, S., Frey, D., Hannula, H., Neuvonen, T., Karhu, J., Vajkoczy, P., & Suess, O.
- Venue
- Neurosurgery
- Published
- 2011-09
- Volume
- 69
- Issue
- 3
- Pages
- 581-589
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W2061823194
- Cited by
- 288
- References
- 13
- FWCI
- 10.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Preoperative Functional Mapping for Rolandic Brain Tumor Surgery: Comparison of Navigated Transcranial Magnetic Stimulation to Direct Cortical Stimulation. https://app.cochat.ai/papers/10.1227/neu.0b013e3182181b89
- The paper
- Picht, T., Schmidt, S., Brandt, S., Frey, D., Hannula, H., Neuvonen, T., Karhu, J., Vajkoczy, P., & Suess, O. (2011). Preoperative Functional Mapping for Rolandic Brain Tumor Surgery: Comparison of Navigated Transcranial Magnetic Stimulation to Direct Cortical Stimulation. Neurosurgery. https://doi.org/10.1227/neu.0b013e3182181b89
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.