A Preliminary Measurement of the Fine Structure Constant Based on Atom Interferometry
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Using an atom interferometer method, we measure the recoil velocity of a cesium atom due to the coherent scattering of a photon. This measurement is used to obtain a value of ℏ/M Cs and the fine structure constant, α. The current fractional uncertainty is Δα/α = 7.4 × 10 -9 .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Observation of electromagnetically induced transparency
Boller, K.-J., Imamoğlu, A., & Harris, S. E. (1991) · Physical Review Letters · doi:10.1103/physrevlett.66.2593 · Cited by 3,058
Atomic interferometry using stimulated Raman transitions
Kasevich, M., & Chu, S. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.181 · Cited by 1,377
Self-citationHigh-precision gravity measurements using atom interferometry
Peters, A., Chung, K. Y., & Chu, S. (2001) · Metrologia · doi:10.1088/0026-1394/38/1/4 · Cited by 965
Self-citationMeasurement of gravitational acceleration by dropping atoms
Peters, A., Chung, K. Y., & Chu, S. (1999) · Nature · doi:10.1038/23655 · Cited by 925
Self-citationAbsolute Optical Frequency Measurement of the CesiumD1Line with a Mode-Locked Laser
Udem, T., Reichert, J., Holzwarth, R., & Hänsch, T. W. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3568 · Cited by 791
Atomic interferometry with internal state labelling
Bordé, C. J. (1989) · Physics Letters A · doi:10.1016/0375-9601(89)90537-9 · Cited by 535
Population switching between vibrational levels in molecular beams
Gaubatz, U., Rudecki, P., Becker, M., Schiemann, S., Külz, M., & Bergmann, K. (1988) · Chemical Physics Letters · doi:10.1016/0009-2614(88)80364-6 · Cited by 296
rf spectroscopy in an atomic fountain
Kasevich, M. A., Riis, E., Chu, S., & DeVoe, R. G. (1989) · Physical Review Letters · doi:10.1103/physrevlett.63.612 · Cited by 286
Self-citationThe Feynman path integral approach to atomic interferometry. A tutorial
Storey, P., & Cohen-Tannoudji, C. (1994) · Journal de Physique II · doi:10.1051/jp2:1994103 · Cited by 252
Penning Trap Measurements of the Masses ofC133s,R87,85b, andN23awith Uncertainties≤0.2ppb
Bradley, M. P., Porto, J. V., Rainville, S., Thompson, J. K., & Pritchard, D. E. (1999) · Physical Review Letters · doi:10.1103/physrevlett.83.4510 · Cited by 214
Direct Optical Resolution of the Recoil Effect Using Saturated Absorption Spectroscopy
Hall, J. L., Bordé, C. J., & Uehara, K. (1976) · Physical Review Letters · doi:10.1103/physrevlett.37.1339 · Cited by 212
Weiss, D. S., Young, B. C., & Chu, S. (1994) · Applied Physics B Lasers and Optics · doi:10.1007/bf01081393 · Cited by 209
Self-citationAtomic Interferometer Based on Adiabatic Population Transfer
Weitz, M., Young, B. C., & Chu, S. (1994) · Physical Review Letters · doi:10.1103/physrevlett.73.2563 · Cited by 201
Self-citationActive low frequency vertical vibration isolation
Hensley, J. M., Peters, A., & Chu, S. (1999) · Review of Scientific Instruments · doi:10.1063/1.1149838 · Cited by 129
Self-citationKinoshita, T. (1996) · Reports on Progress in Physics · doi:10.1088/0034-4885/59/11/003 · Cited by 126
Weitz, M., Young, B. C., & Chu, S. (1994) · Physical Review A · doi:10.1103/physreva.50.2438 · Cited by 85
Self-citation
Cited by
CODATA recommended values of the fundamental physical constants: 2010
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2012) · Reviews of Modern Physics · doi:10.1103/revmodphys.84.1527 · Cited by 2,441
Search for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560
Optics and interferometry with atoms and molecules
Cronin, A. D., Schmiedmayer, J., & Pritchard, D. E. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.1051 · Cited by 1,420
CODATA recommended values of the fundamental physical constants: 2006
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2008) · Reviews of Modern Physics · doi:10.1103/revmodphys.80.633 · Cited by 952
CODATA recommended values of the fundamental physical constants: 2014
Mohr, P. J., Newell, D. B., & Taylor, B. N. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.035009 · Cited by 920
Metadata
- Authors
- Wicht, A., Hensley, J. M., Sarajlic, E., & Chu, S.
- Venue
- Physica Scripta
- Publisher
- IOP Publishing
- Published
- 2002
- Volume
- T102
- Issue
- 1
- Pages
- 82
- ISSN
- 0031-8949 (ISSN-L)
- OpenAlex
- W1971150181
- Cited by
- 260
- References
- 16
- FWCI
- 4.25
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.