The DOI matches its Crossref record.
Mechanical compression alters proteoglycan deposition and matrix deformation around individual cells in cartilage explants
Abstract
We have used new techniques of cell-length scale quantitative autoradiography to assess matrix synthesis, deposition, and deformation around individual chondrocytes in mechanically compressed cartilage explants. Our objectives were to: (1) quantify the effects of static and dynamic compression on the deposition of newly synthesized proteoglycans into cell-associated and further-removed matrices; (2) measure cell-length scale matrix strains and morphological changes of the cell and matrix associated with tissue compression; and (3) relate microscopic physical stimuli to changes in proteoglycan synthesis as functions of compression level and position within mechanically compressed explants. Results indicate a high degree of structural organization in the extracellular matrix, with the pericellular matrix associated with the most rapid rates of proteoglycan deposition, and greatest sensitivity to mechanical compression. Static compression could stimulate directional deposition of secreted proteoglycans around chondrocytes, superimposed on an inhibition of proteoglycan synthesis; these events followed trends for compressive strain in the cell-associated matrix. Conversely, proteoglycan synthesis and pericellular deposition was stimulated by dynamic compression. Results suggest that cell-matrix interactions in the cell-associated matrix may be a particularly important aspect of the chondrocyte response to mechanical compression, possibly involving macromolecular transport limitations and morphological changes associated with fluid flow and local compaction of the matrix around cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Capturing complex 3D tissue physiology in vitro
Griffith, L. G., & Swartz, M. A. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1858 · Cited by 2,290
Interstitial Flow and Its Effects in Soft Tissues
Swartz, M. A., & Fleury, M. E. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151850 · Cited by 598
Cell mechanics and mechanotransduction: pathways, probes, and physiology
Huang, H., Kamm, R. D., & Lee, R. T. (2004) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00559.2003 · Cited by 548
Lee, W., Leddy, H. A., Chen, Y., Lee, S. H., Zelenski, N. A., McNulty, A. L., Wu, J., Beicker, K. N., Coles, J., Zauscher, S., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1414298111 · Cited by 460
Knee Kinematics, Cartilage Morphology, and Osteoarthritis after ACL Injury
CHAUDHARI, A. M. W., BRIANT, P. L., BEVILL, S. L., KOO, S., & ANDRIACCHI, T. P. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815cbb0e · Cited by 399
Metadata
- Authors
- Quinn, T. M., Grodzinsky, A. J., Buschmann, M. D., Kim, Y.-J., & Hunziker, E. B.
- Venue
- Journal of Cell Science
- Publisher
- The Company of Biologists
- Published
- 1998-03-01
- Volume
- 111
- Issue
- 5
- Pages
- 573-583
- ISSN
- 0021-9533 (ISSN-L)
- 1477-9137
- OpenAlex
- W2186680027
- Cited by
- 230
- References
- 0
- FWCI
- 7.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical compression alters proteoglycan deposition and matrix deformation around individual cells in cartilage explants. https://app.cochat.ai/papers/10.1242/jcs.111.5.573
- The paper
- Quinn, T. M., Grodzinsky, A. J., Buschmann, M. D., Kim, Y.-J., & Hunziker, E. B. (1998). Mechanical compression alters proteoglycan deposition and matrix deformation around individual cells in cartilage explants. Journal of Cell Science. https://doi.org/10.1242/jcs.111.5.573
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.