Flight Physiology Of Flying Foxes, Pteropus Poliocephalus
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Oxygen consumption was measured during flight in two flying foxes (Pteropus poliocephalus) at airspeeds of 4–8·6 ms−1. There was good agreement with the measured power input of the only previously measured large bat, and with an allometric equation predicting power input for flying vertebrates. Measurements of respiratory exchange ratios, pulmonary water loss, respiratory frequencies, heart rates and body temperatures of both bats flying at intermediate airspeeds were compared with equivalent measurements on other bats or birds in flight. Despite a high non-evaporative thermal conductance in flight, the P. poliocephalus became severely hyperthermic at ambient temperatures (Ta) above 25°C. The failure to dissipate heat as successfully as flying birds at high Ta is apparently the result of an inability to increase pulmonary ventilation rates, and thus increase rates of evaporative heat loss. The effect of airspeed on endurance was measured systematically on one bat. Endurance was not limited by energy reserves at all airspeeds, and flight times were significantly greater at the airspeed of minimum power input (Vmp). The endurance of both bats was so reduced at the higher airspeeds that they would not achieve maximum flight range in still air at the velocity where cost of locomotion is lowest. Contrary to a common assumption, flight range would be maximized at the Vmp.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scaling of respiratory variables in mammals
Stahl, W. R. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.22.3.453 · Cited by 853
Evaporative Cooling and Water Balance During Flight In Birds
Torre-Bueno, J. R. (1978) · Journal of Experimental Biology · doi:10.1242/jeb.75.1.231 · Cited by 77
Cited by
Norberg, U. M., & Rayner, J. M. V. (1987) · Philosophical Transactions of the Royal Society of London. B, Biological Sciences · doi:10.1098/rstb.1987.0030 · Cited by 1,805
Maximum lift production during takeoff in flying animals
Marden, J. H. (1987) · Journal of Experimental Biology · doi:10.1242/jeb.130.1.235 · Cited by 441
The evolution of cost efficient swimming in marine mammals: limits to energetic optimization
Williams, T. M. (1999) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1999.0371 · Cited by 299
Mechanics of Forward Flight in Bumblebees: I. Kinematics and Morphology
Dudley, R., & Ellington, C. P. (1990) · Journal of Experimental Biology · doi:10.1242/jeb.148.1.19 · Cited by 290
Limitations on Animal Flight Performance
Ellington, C. P. (1991) · Journal of Experimental Biology · doi:10.1242/jeb.160.1.71 · Cited by 254
Metadata
- Authors
- Carpenter, R. E.
- Venue
- Journal of Experimental Biology
- Publisher
- The Company of Biologists
- Published
- 1985-01-01
- Volume
- 114
- Issue
- 1
- Pages
- 619-647
- ISSN
- 0022-0949 (ISSN-L)
- 1477-9145
- OpenAlex
- W2282100315
- Cited by
- 76
- References
- 2
- FWCI
- 4.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.