In vivo strains in pigeon flight feather shafts: implications for structural design
The DOI matches its Crossref record.
Abstract
To evaluate the safety factor for flight feather shafts, in vivo strains were recorded during free flight from the dorsal surface of a variety of flight feathers of captive pigeons (Columba livia) using metal foil strain gauges. Strains recorded while the birds flew at a slow speed (approximately 5-6 m s-1) were used to calculate functional stresses on the basis of published values for the elastic modulus of feather keratin. These stresses were then compared with measurements of the failure stress obtained from four-point bending tests of whole sections of the rachis at a similar location. Recorded strains followed an oscillatory pattern, changing from tensile strain during the upstroke to compressive strain during the downstroke. Peak compressive strains were 2.2+/-0. 9 times (mean +/- s.d.) greater than peak tensile strains. Tensile strain peaks were generally not as large in more proximal flight feathers. Maximal compressive strains averaged -0.0033+/-0.0012 and occurred late in the downstroke. Bending tests demonstrated that feather shafts are most likely to fail through local buckling of their compact keratin cortex. A comparison of the mean (8.3 MPa) and maximum (15.7 MPa) peak stresses calculated from the in vivo strain recordings with the mean failure stress measured in four-point bending (137 MPa) yields a safety factor of between 9 and 17. Under more strenuous flight conditions, feather stresses are estimated to be 1.4-fold higher, reducing their safety factor to the range 6-12. These values seem high, considering that the safety factor of the humerus of pigeons has been estimated to be between 1.9 and 3.5. Several hypotheses explaining this difference in safety factor are considered, but the most reasonable explanation appears to be that flexural stiffness is more critical than strength to feather shaft performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biological materials: Structure and mechanical properties
Meyers, M. A., Chen, P.-Y., Lin, A. Y.-M., & Seki, Y. (2008) · Progress in Materials Science · doi:10.1016/j.pmatsci.2007.05.002 · Cited by 2,573
Wang, B., Yang, W., McKittrick, J., & Meyers, M. A. (2016) · Progress in Materials Science · doi:10.1016/j.pmatsci.2015.06.001 · Cited by 873
Adaptationism – how to carry out an exaptationist program
Andrews, P. W., Gangestad, S. W., & Matthews, D. (2002) · Behavioral and Brain Sciences · doi:10.1017/s0140525x02000092 · Cited by 370
Effects of Body Size on Take-off Flight Performance in the Phasianidae (Aves)
Tobalske, B. W., & Dial, K. P. (2000) · Journal of Experimental Biology · doi:10.1242/jeb.203.21.3319 · Cited by 135
Flexural stiffness of feather shafts: geometry rules over material properties
Bachmann, T., Emmerlich, J., Baumgartner, W., Schneider, J. M., & Wagner, H. (2012) · Journal of Experimental Biology · doi:10.1242/jeb.059451 · Cited by 107
Metadata
- Authors
- Corning, W., & Biewener, A.
- Venue
- Journal of Experimental Biology
- Publisher
- The Company of Biologists
- Published
- 1998-11-01
- Volume
- 201
- Issue
- 22
- Pages
- 3057-3065
- ISSN
- 0022-0949 (ISSN-L)
- 1477-9145
- OpenAlex
- W2112159968
- Cited by
- 76
- References
- 0
- FWCI
- 6.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo strains in pigeon flight feather shafts: implications for structural design. https://app.cochat.ai/papers/10.1242/jeb.201.22.3057
- The paper
- Corning, W., & Biewener, A. (1998). In vivo strains in pigeon flight feather shafts: implications for structural design. Journal of Experimental Biology. https://doi.org/10.1242/jeb.201.22.3057
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.