CoChat

Comparison of integrated micro-electrical-mechanical system and piezoelectric accelerometers for machine condition monitoring

Thanagasundram, S, Schlindwein, F S · 2006 · Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science

The DOI matches its Crossref record; 8 of the 9 references it cites were found in a registry or an index.

Abstract

The design and implementation of instrumentation to collect real-time vibrational data from a quasi-steady state machine (a dry vacuum pump) for fault prediction diagnostics is presented. When simultaneous multiple data collection points are required on the same machinery, the use of conventional transducers such as piezoelectric accelerometers becomes impractical due to their price, as each needs an expensive associated charge amplifier. The use of inexpensive micromachined integrated micro-electrical-mechanical system accelerometers such as ADXL105 has been explored here as an alternative to piezoelectric accelerometers for obtaining reliable and predictable data for diagnostics. Surface micromachined accelerometers are a new technology and their usage for vibrational analysis has been conservative due to concerns over increased noise levels and tolerance to high temperatures. In this article, it is shown that such concerns can be allayed. The time and frequency domain vibration signatures obtained using both types of accelerometers are compared. The study shows that ADXL105 accelerometers can be an effective alternative low-cost high-quality solution for machine condition monitoring.

Overview

Integrity signals

Registry

Crossref · 10.1243/09544062c07405

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 8 references

Research works printed but not linked: 6

  1. Sabin E., 1995, Semicond. Int., 18, 249
  2. Mechefske C. K., 1993, Brit. J. Non-Destr. Test., 35, 574
  3. Doscher J., 1999, Analogue Dialogue, 33, 27
  4. Doscher J. Using iMEMS accelerometers in instrumentation applications. Proceedings of the 45th International Instrumentation Symposium, Instrument Society of America, 1999, pp. 395–404.
  5. Doscher J., 1997, Sensors, 14, 33
  6. 1999, ADXL105, Datasheet

Cited by

See all 36

Metadata

Authors
Thanagasundram, S., & Schlindwein, F. S.
Affiliations
University of Leicester (GB)
Venue
Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
Published
2006-08-01
Volume
220
Issue
8
Pages
1135-1146
ISSN
  • 0263-7154 (ISSN-L)
  • 0954-4062
  • 2041-2983
OpenAlex
W2064936868
Cited by
36
References
9
Citations by year
2026: 1 · 2025: 1 · 2024: 2 · 2023: 3 · 2022: 1 · 2021: 1 · 2020: 2 · 2019: 1 · 2018: 3 · 2017: 1 · 2016: 5 · 2015: 1 · 2013: 2 · 2012: 1
FWCI
4.57
Type
journal article
Language
en
Open access
closed
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science (publishedVersion)
  • Leicester Research Archive (University of Leicester) (submittedVersion)
Funders
Engineering and Physical Sciences Research Council
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
  • Physical Sciences › Physics and Astronomy › Instrumentation › Sensor Technology and Measurement Systems
Keywords
machine condition monitoring, MEMS accelerometer, piezoelectric accelerometer, vibration analysis, dry vacuum pump, fault prediction, surface micromachining, low-cost instrumentation, vibration signatures

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of integrated micro-electrical-mechanical system and piezoelectric accelerometers for machine condition monitoring. https://app.cochat.ai/papers/10.1243/09544062c07405
The paper
Thanagasundram, S., & Schlindwein, F. S. (2006). Comparison of integrated micro-electrical-mechanical system and piezoelectric accelerometers for machine condition monitoring. Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science. https://doi.org/10.1243/09544062c07405

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.