Computer-based detection of diabetes retinopathy stages using digital fundus images
Abstract
Diabetes mellitus is a heterogeneous clinical syndrome characterized by hyperglycaemia and the long-term complications are retinopathy, neuropathy, nephropathy, and cardiomyopathy. It is a leading cause of blindness. Diabetic retinopathy is the progressive pathological alterations in the retinal microvasculature, leading to areas of retinal nonperfusion, increased vascular permeability, and the pathological proliferation of retinal vessels. Hence, it is beneficial to have regular cost-effective eye screening for diabetes subjects. Nowadays, different stages of diabetes retinopathy are detected by retinal examination using indirect biomicroscopy by senior ophthalmologists. In this work, morphological image processing and support vector machine (SVM) techniques were used for the automatic diagnosis of eye health. In this study, 331 fundus images were analysed. Five groups were identified: normal retina, mild non-proliferative diabetic retinopathy, moderate non-proliferative diabetic retinopathy, severe non-proliferative diabetic retinopathy, and proliferative diabetic retinopathy. Four salient features blood vessels, microaneurysms, exudates, and haemorrhages were extracted from the raw images using image-processing techniques and fed to the SVM for classification. A sensitivity of more than 82 per cent and specificity of 86 per cent was demonstrated for the system developed.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Acharya et al. reported that a system using morphological image processing and SVM on retinal images could identify different stages of DR with an average accuracy of more than 85%, a sensitivity of 82%, and a specificity of 86%.
“the system could identify different stages of DR with an average accuracy of more than 85%, a sensitivity of 82%, and a specificity of 86%”
From Artificial intelligence in diabetes management: Advancements, opportunities, and challenges (2023) · cites this paper as Acharya et al.108
Cited by
Sorted by citations
Artificial intelligence in diabetes management: Advancements, opportunities, and challenges
Guan, Z., Li, H., Liu, R., Cai, C., Liu, Y., Li, J., Wang, X., Huang, S., Wu, L., Liu, D., et al. (2023) · Cell Reports Medicine · doi:10.1016/j.xcrm.2023.101213 · Cited by 287 · see citing works
- Authors
- Acharya, U. R., Lim, C. M., Ng, E. Y. K., Chee, C., & Tamura, T.
- Affiliations
- Ngee Ann Polytechnic (SG)
- Nanyang Technological University (SG)
- National University Hospital (SG)
- Chiba University (JP)
- Venue
- Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Publisher
- SAGE Publications
- Published
- 2009-03-27
- Volume
- 223
- Issue
- 5
- Pages
- 545-553
- ISSN
- 0954-4119 (ISSN-L)
- 2041-3033
- OpenAlex
- W2005394924
- Cited by
- 217
- References
- 0
- Citations by year
- 2026: 8 · 2025: 6 · 2024: 8 · 2023: 26 · 2022: 18 · 2021: 22 · 2020: 21 · 2019: 20 · 2018: 17 · 2017: 13 · 2016: 7 · 2015: 7 · 2014: 8 · 2013: 9 · 2012: 18
- FWCI
- 6.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
- Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
- Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Health Research
- Keywords
- diabetic retinopathy, retinopathy staging, fundus images, computer-aided diagnosis, non-proliferative diabetic retinopathy, proliferative diabetic retinopathy, microaneurysms, retinal exudates, retinal hemorrhage, retinal vasculature, support vector machine classification, image feature extraction, diabetic retinopathy screening
- MeSH terms
- Adult, Aged, Algorithms, Artificial Intelligence, Diabetic Retinopathy, Female, Humans, Image Enhancement, Image Interpretation, Computer-Assisted, Male, Middle Aged, Pattern Recognition, Automated, Sensitivity and Specificity, Signal Processing, Computer-Assisted, Reproducibility of Results, Retinoscopy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review