A two-degree-of-freedom motor-powered gait orthosis for spinal cord injury patients
The DOI matches its Crossref record.
Abstract
A number of orthoses have been developed to restore stance and walking in paraplegic subjects. Compliance, however, has been limited, mainly owing to walking effort. Use of the forces produced by actuators is an effective way to solve the problem of the considerable effort required for orthotic gait, namely high muscular effort and high energy expenditure. The purpose of the present study was to investigate the effects of assistance by external actuators on the orthotic gait of spinal cord injury (SCI) patients. Two kinds of linear actuator were developed by using direct current (d.c.) motors for assisting the knee and hip joint of a gait orthosis. They were mounted on the knee and hip joint of a commercial advanced reciprocating gait orthosis (ARGO), and a new two-degree-of-freedom externally powered gait orthosis was thus developed. The orthosis was assessed through inter-subject experiments on five male adult complete SCI patients. Owing to the short training period available for the assisted gait, simultaneous operation of both joint actuators was not conducted: either the knee actuation or the hip actuation was executed only. Thus, the knee actuator and the hip actuator were assessed with a T12 subject and with subjects for T5, T8, T11, and T12 respectively. The motions of the gaits, assisted by the linear actuators, were measured by a Vicon 370 system, and the general gait parameters and compensatory motions were evaluated. Results demonstrated that (a) all subjects could walk without falling, assisted either by the knee or the hip actuator; (b) both the knee and hip joint actuator increased the gait speed and the step length; (c) the knee flexion produced by the orthosis improved the dynamic cosmesis of walking; and (d) lateral compensatory motions as well as vertical ones tended to decrease when the hip joint was assisted, which could contribute to a reduction in walking effort.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lower Limb Wearable Robots for Assistance and Rehabilitation: A State of the Art
Huo, W., Mohammed, S., Moreno, J. C., & Amirat, Y. (2016) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2351491 · Cited by 455
A biologically inspired soft exosuit for walking assistance
Asbeck, A. T., De Rossi, S. M. M., Holt, K. G., & Walsh, C. J. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364914562476 · Cited by 450
“Several were designed exclusively for use by impaired individuals (Ohta et al., 2007; Quintero et al., 2011; Shorter et al., 2011), and these have been shown to improve walking speed or partially restore normal kinematics.”
BackgroundPreliminary Evaluation of a Powered Lower Limb Orthosis to Aid Walking in Paraplegic Individuals
Farris, R. J., Quintero, H. A., & Goldfarb, M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2163083 · Cited by 342
Farris, R. J., Quintero, H. A., Murray, S. A., Ha, K. H., Hartigan, C., & Goldfarb, M. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2268320 · Cited by 208
“In [8], the authors assess the efficacy of a powered orthosis, relative to a passive reciprocating gait orthosis, by reporting average walking speed; average step length; and the vertical and lateral motion amplitude of each subject’s head.”
BackgroundSoft exosuit for hip assistance
Asbeck, A. T., Schmidt, K., & Walsh, C. J. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.025 · Cited by 167
“[1, 2, 3, 4], while others support a paraplegic’s bodyweight [5, 6, 7, 8, 9, 10].”
BackgroundA Method for the Autonomous Control of Lower Limb Exoskeletons for Persons With Paraplegia
Quintero, H. A., Farris, R. J., & Goldfarb, M. (2012) · Journal of Medical Devices · doi:10.1115/1.4007181 · Cited by 97
“, [5-16]), the authors focus on the capacity of their respective systems to provide legged mobility, but do not focus on specifically on control methods that enable the user to autonomously command various movements.”
Background
Metadata
- Authors
- Ohta, Y., Yano, H., Suzuki, R., Yoshida, M., Kawashima, N., & Nakazawa, K.
- Venue
- Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Publisher
- SAGE Publications
- Published
- 2007-06-01
- Volume
- 221
- Issue
- 6
- Pages
- 629-639
- ISSN
- 0954-4119 (ISSN-L)
- 2041-3033
- OpenAlex
- W1977390009
- Cited by
- 73
- References
- 0
- FWCI
- 1.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.