Three-dimensional ultrasound imaging
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
This review is about the development of three-dimensional (3D) ultrasonic medical imaging, how it works, and where its future lies. It assumes knowledge of two-dimensional (2D) ultrasound, which is covered elsewhere in this issue. The three main ways in which 3D ultrasound may be acquired are described: the mechanically swept 3D probe, the 2D transducer array that can acquire intrinsically 3D data, and the freehand 3D ultrasound. This provides an appreciation of the constraints implicit in each of these approaches together with their strengths and weaknesses. Then some of the techniques that are used for processing the 3D data and the way this can lead to information of clinical value are discussed. A table is provided to show the range of clinical applications reported in the literature. Finally, the discussion relating to the technology and its clinical applications to explain why 3D ultrasound has been relatively slow to be adopted in routine clinics is drawn together and the issues that will govern its development in the future explored.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157
Three-dimensional ultrasound imaging
Fenster, A., Downey, D. B., & Cardinal, H. N. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/5/201 · Cited by 812
Wegrzyn, P., Faro, C., Falcon, O., Peralta, C. F. A., & Nicolaides, K. H. (2005) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.1923 · Cited by 103
2d/3d Registration of Endoscopic Ultrasound to Ct Volume Data
Hummel, J., Figl, M., Bax, M., Bergmann, H., & Birkfellner, W. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/16/006 · Cited by 47
Cited by
A Review on Real-Time 3D Ultrasound Imaging Technology
Huang, Q., & Zeng, Z. (2017) · BioMed Research International · doi:10.1155/2017/6027029 · Cited by 334
Freehand 3-D Ultrasound Imaging: A Systematic Review
Mozaffari, M. H., & Lee, W.-S. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.06.009 · Cited by 159
MEDICAL DEVICES EARLY ASSESSMENT METHODS: SYSTEMATIC LITERATURE REVIEW
Markiewicz, K., van Til, J. A., & IJzerman, M. J. (2014) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462314000026 · Cited by 87
Metadata
- Authors
- Prager, R. W., Ijaz, U. Z., Gee, A. H., & Treece, G. M.
- Venue
- Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Publisher
- SAGE Publications
- Published
- 2010-02-01
- Volume
- 224
- Issue
- 2
- Pages
- 193-223
- ISSN
- 0954-4119 (ISSN-L)
- 2041-3033
- OpenAlex
- W2134470795
- Cited by
- 162
- References
- 4
- FWCI
- 5.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-dimensional ultrasound imaging. https://app.cochat.ai/papers/10.1243/09544119jeim586
- The paper
- Prager, R. W., Ijaz, U. Z., Gee, A. H., & Treece, G. M. (2010). Three-dimensional ultrasound imaging. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. https://doi.org/10.1243/09544119jeim586
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.