The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A review of medical robotics for minimally invasive soft tissue surgery
Open accessAbstract
This paper provides an overview of recent trends and developments in medical robotics for minimally invasive soft tissue surgery, with a view to highlight some of the issues posed and solutions proposed in the literature. The paper includes a thorough review of the literature, which focuses on soft tissue surgical robots developed and published in the last five years (between 2004 and 2008) in indexed journals and conference proceedings. Only surgical systems were considered; imaging and diagnostic devices were excluded from the review. The systems included in this paper are classified according to the following surgical specialties: neurosurgery; eye surgery and ear, nose, and throat (ENT); general, thoracic, and cardiac surgery; gastrointestinal and colorectal surgery; and urologic surgery. The systems are also cross-classified according to their engineering design and robotics technology, which is included in tabular form at the end of the paper. The review concludes with an overview of the field, along with some statistical considerations about the size, geographical spread, and impact of medical robotics for soft tissue surgery today.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applied force during vitreoretinal microsurgery with handheld instruments
Jagtap, A. D., & Riviere, C. N. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1403792 · Cited by 79
Active tremor compensation in microsurgery
Ang, W. T., Pradeep, P. K., & Riviere, C. N. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1403784 · Cited by 61
Cited by
Shape Sensing Techniques for Continuum Robots in Minimally Invasive Surgery: A Survey
Shi, C., Luo, X., Qi, P., Li, T., Song, S., Najdovski, Z., Fukuda, T., & Ren, H. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2622361 · Cited by 420
Medical Robots: Current Systems and Research Directions
Beasley, R. A. (2012) · Journal of Robotics · doi:10.1155/2012/401613 · Cited by 312
Micron: An Actively Stabilized Handheld Tool for Microsurgery
MacLachlan, R. A., Becker, B. C., Tabares, J. C., Podnar, G. W., Lobes, L. A., & Riviere, C. N. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2169634 · Cited by 270
Endovascular Microrobotics for Neurointervention
Santiago-Dieppa, D. R., & Friend, J. (2024) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-060523-010720 · Cited by 12
Metadata
- Authors
- Dogangil, G., Davies, B. L., & Rodriguez y Baena, F.
- Venue
- Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Publisher
- SAGE Publications
- Published
- 2009-07-30
- Volume
- 224
- Issue
- 5
- Pages
- 653-679
- ISSN
- 0954-4119 (ISSN-L)
- 2041-3033
- OpenAlex
- W2064622479
- Cited by
- 225
- References
- 2
- FWCI
- 5.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A review of medical robotics for minimally invasive soft tissue surgery. https://app.cochat.ai/papers/10.1243/09544119jeim591
- The paper
- Dogangil, G., Davies, B. L., & Rodriguez y Baena, F. (2010). A review of medical robotics for minimally invasive soft tissue surgery. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. https://doi.org/10.1243/09544119jeim591
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.