Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 180

The DOI matches its Crossref record.

Transmission of the Load in the Knee Joint with Special Reference to the Role of the Menisci: Part I: Anatomy, Analysis and Apparatus

Seedhom, B B·1979·Engineering in Medicine

Abstract

The menisci of the knee joint transmit a considerable fraction of the total load acting on the joint. This paper describes an investigation into the load carrying capacity of the individual meniscus. Interest is also directed to an examination of the function of the degenerate meniscus and that of the meniscus with different kinds of tears. Quantifying the meniscal loads is based on a four-spring model representing the load bearing areas in the knee with intact menisci. The assumptions underlying the model are discussed and the problems of loading associated with the four-spring model are described. These problems called for careful consideration of the methods of loading and aligning the joint. A loading machine with a special aligning device was built for the experimental work. The experimental procedure is described in Part II. The intact individual meniscus was shown to transmit 70-99 per cent of the load acting on the respective side. The load carrying capacity of the meniscus was shown to decrease following the removal of a simulated ‘bucket-handle’ tear but in some cases it remained virtually unaltered. The stresses in the knee with redundant menisci were shown to increase by three to five fold their magnitude in the knee with intact menisci. Following removal of a simulated bucket-handle' tear, the stresses increased, but much less dramatically. The clinical implications of total and partial meniscectomy are discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1243/emed_jour_1979_008_050_02

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 180

Metadata

Authors
Seedhom, B. B.
Venue
Engineering in Medicine
Published
1979-10
Volume
8
Issue
4
Pages
207-219
ISSN
  • 0046-2039 (ISSN-L)
  • 2058-3400
OpenAlex
W2091753750
Cited by
180
References
0
FWCI
1.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transmission of the Load in the Knee Joint with Special Reference to the Role of the Menisci: Part I: Anatomy, Analysis and Apparatus. https://app.cochat.ai/papers/10.1243/emed_jour_1979_008_050_02
The paper
Seedhom, B. B. (1979). Transmission of the Load in the Knee Joint with Special Reference to the Role of the Menisci: Part I: Anatomy, Analysis and Apparatus. Engineering in Medicine. https://doi.org/10.1243/emed_jour_1979_008_050_02

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.