The Learning Curve for Robotic Thyroidectomy: A Multicenter Study
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PurposeThe learning curve for robotic thyroidectomy with central compartment node dissection (CCND) has not been established. We examined the effect of experience of robotic thyroidectomy on a range of perioperative parameters in order to determine the learning curve. The learner surgeon outcomes were compared with those of an experienced surgeon.MethodsWe conducted a prospective, controlled, multicenter study involving four endocrine surgeons at three academic centers. Patients underwent robotic total or subtotal thyroidectomy with CCND between September 2008 and October 2009. One surgeon was experienced in the technique (experienced surgeon, ES), while the other three surgeons had endoscopic thyroid surgery experience but no experience performing the robotic procedure (nonrobotic thyroid surgery experienced surgeon, NS). Outcome measures were demographic data, operative time, blood loss, hospital stay, pathologic results, and postoperative complications.ResultsA total of 644 total or subtotal robotic thyroidectomies with CCND were performed: 377 (58.7%) by NSs and 267 (41.5%) by the ES. Mean operative time was longer and the complication rate was higher for the NS patient group compared with the ES patient group (P < 0.001 for each). The operative times and complications rates for the NS group were similar to those of the ES group once the NSs had performed 50 cases for total thyroidectomies or 40 cases for subtotal thyroidectomies.ConclusionThe learning curve duration for robotic thyroidectomy with CCND using gasless transaxillary approach for experienced endoscopic thyroidectomy surgeons was 50 cases for total thyroidectomy and 40 cases for subtotal thyroidectomy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Haugen, B. R., Alexander, E. K., Bible, K. C., Doherty, G. M., Mandel, S. J., Nikiforov, Y. E., Pacini, F., Randolph, G. W., Sawka, A. M., Schlumberger, M., et al. (2016) · Thyroid® · doi:10.1089/thy.2015.0020 · Cited by 16,535
Cooper, D. S., Doherty, G. M., Haugen, B. R., Kloos, R. T., Lee, S. L., Mandel, S. J., Mazzaferri, E. L., McIver, B., Pacini, F., Schlumberger, M., et al. (2009) · Thyroid · doi:10.1089/thy.2009.0110 · Cited by 6,707
Cited by
Haugen, B. R., Alexander, E. K., Bible, K. C., Doherty, G. M., Mandel, S. J., Nikiforov, Y. E., Pacini, F., Randolph, G. W., Sawka, A. M., Schlumberger, M., et al. (2016) · Thyroid® · doi:10.1089/thy.2015.0020 · Cited by 16,535
Cooper, D. S., Doherty, G. M., Haugen, B. R., Kloos, R. T., Lee, S. L., Mandel, S. J., Mazzaferri, E. L., McIver, B., Pacini, F., Schlumberger, M., et al. (2009) · Thyroid · doi:10.1089/thy.2009.0110 · Cited by 6,707
Adverse Events in Robotic Surgery: A Retrospective Study of 14 Years of FDA Data
Alemzadeh, H., Raman, J., Leveson, N., Kalbarczyk, Z., & Iyer, R. K. (2016) · PLOS ONE · doi:10.1371/journal.pone.0151470 · Cited by 441
Robotic Transaxillary Thyroidectomy: An Examination of the First One Hundred Cases
Kandil, E. H., Noureldine, S. I., Yao, L., & Slakey, D. P. (2012) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2012.01.002 · Cited by 206
“This approach is intended to be scarless neck surgery, resulting in less pain and a faster return to functional activities.(17) As for the introduction of new technology to any urgery, a framework for the safe implementation of this echnique has been outlined to avoid any unnecessary arm to patients, surgeons, and soc…”
Background
Metadata
- Authors
- Lee, J., Yun, J. H., Nam, K. H., Soh, E.-Y., & Chung, W. Y.
- Venue
- Annals of Surgical Oncology
- Published
- 2010-08-03
- Volume
- 18
- Issue
- 1
- Pages
- 226-232
- ISSN
- 1068-9265 (ISSN-L)
- 1534-4681
- OpenAlex
- W2002418803
- Cited by
- 174
- References
- 2
- FWCI
- 15.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Learning Curve for Robotic Thyroidectomy: A Multicenter Study. https://app.cochat.ai/papers/10.1245/s10434-010-1220-z
- The paper
- Lee, J., Yun, J. H., Nam, K. H., Soh, E.-Y., & Chung, W. Y. (2011). The Learning Curve for Robotic Thyroidectomy: A Multicenter Study. Annals of Surgical Oncology. https://doi.org/10.1245/s10434-010-1220-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.