A Randomized Prospective Study of Lumpectomy Margin Assessment with Use of MarginProbe in Patients with Nonpalpable Breast Malignancies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The presence of tumor cells at the margins of breast lumpectomy specimens is associated with an increased risk of ipsilateral tumor recurrence. Twenty to 30 % of patients undergoing breast-conserving surgery require second procedures to achieve negative margins. This study evaluated the adjunctive use of the MarginProbe device (Dune Medical Devices Ltd, Caesarea, Israel) in providing real-time intraoperative assessment of lumpectomy margins. METHODS: This multicenter randomized trial enrolled patients with nonpalpable breast malignancies. The study evaluated MarginProbe use in addition to standard intraoperative methods for margin assessment. After specimen removal and inspection, patients were randomized to device or control arms. In the device arm, MarginProbe was used to examine the main lumpectomy specimens and direct additional excision of positive margins. Intraoperative imaging was used in both arms; no intraoperative pathology assessment was permitted. RESULTS: In total, 596 patients were enrolled. False-negative rates were 24.8 and 66.1 % and false-positive rates were 53.6 and 16.6 % in the device and control arms, respectively. All positive margins on positive main specimens were resected in 62 % (101 of 163) of cases in the device arm, versus 22 % (33 of 147) in the control arm (p < 0.001). A total of 19.8 % (59 of 298) of patients in the device arm underwent a reexcision procedure compared with 25.8 % (77 of 298) in the control arm (6 % absolute, 23 % relative reduction). The difference in tissue volume removed was not significant. CONCLUSIONS: Adjunctive use of the MarginProbe device during breast-conserving surgery improved surgeons' ability to identify and resect positive lumpectomy margins in the absence of intraoperative pathology assessment, reducing the number of patients requiring reexcision. MarginProbe may aid performance of breast-conserving surgery by reducing the burden of reexcision procedures for patients and the health care system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vaidya, J. S., Joseph, D. J., Tobias, J. S., Bulsara, M., Wenz, F., Saunders, C., Alvarado, M., Flyger, H. L., Massarut, S., Eiermann, W., et al. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60837-9 · Cited by 772
Houssami, N., Macaskill, P., Luke Marinovich, M., & Morrow, M. (2014) · Annals of Surgical Oncology · doi:10.1245/s10434-014-3480-5 · Cited by 532
Variability in Reexcision Following Breast Conservation Surgery
McCahill, L. E., Single, R. M., Aiello Bowles, E. J., Feigelson, H. S., James, T. A., Barney, T., Engel, J. M., & Onitilo, A. A. (2012) · JAMA · doi:10.1001/jama.2012.43 · Cited by 516
Houssami, N., Macaskill, P., Marinovich, M. L., Dixon, J. M., Irwig, L., Brennan, M. E., & Solin, L. J. (2010) · European Journal of Cancer · doi:10.1016/j.ejca.2010.07.043 · Cited by 406
Jeevan, R., Cromwell, D. A., Trivella, M., Lawrence, G., Kearins, O., Pereira, J., Sheppard, C., Caddy, C. M., & van der Meulen, J. H. P. (2012) · BMJ · doi:10.1136/bmj.e4505 · Cited by 347
Dunne, C., Burke, J. P., Morrow, M., & Kell, M. R. (2009) · Journal of Clinical Oncology · doi:10.1200/jco.2008.17.5182 · Cited by 321
Haloua, M. H., Krekel, N. M. A., Winters, H. A. H., Rietveld, D. H. F., Meijer, S., Bloemers, F. W., & van den Tol, M. P. (2013) · Annals of Surgery · doi:10.1097/sla.0b013e3182888782 · Cited by 201 · cited 1×
“Reexcision procedures may be difficult in these cases because it can be virtually impossible to accurately identify the specific margin to be reexcised.(22)”
BackgroundAziz, D., Rawlinson, E., Narod, S. A., Sun, P., Lickley, H. L. A., McCready, D. R., & Holloway, C. M. B. (2006) · The Breast Journal · doi:10.1111/j.1075-122x.2006.00271.x · Cited by 149
Blair, S. L., Thompson, K., Rococco, J., Malcarne, V. L., Beitsch, P. D., & Ollila, D. W. (2009) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2009.07.026 · Cited by 142 · cited 1×
“There is variability in defining acceptable margin width among surgeons and radiation oncologists.(12,13)”
BackgroundThill, M. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.13.5 · Cited by 90
Diagnostic Performance of a Novel Device for Real-Time Margin Assessment in Lumpectomy Specimens
Pappo, I., Spector, R., Schindel, A., Morgenstern, S., Sandbank, J., Leider, L. T., Schneebaum, S., LELCUK, S., & Karni, T. (2009) · Journal of Surgical Research · doi:10.1016/j.jss.2009.02.025 · Cited by 87 · cited 1×
“The threshold for a positive reading was set based on readings directly compared to pathology results.(10) The diagnostic performance was sensitivity 70–100 % and specificity 70–87 %, depending on the cancer feature size.”
MethodSelf-citationTaghian, A. G., Jagsi, R., Makris, A., Goldberg, S. I., Ceilley, E., Grignon, L., & Powell, S. N. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.04.027 · Cited by 70
Do additional shaved margins at the time of lumpectomy eliminate the need for re-excision?
Jacobson, A. F., Asad, J., Boolbol, S. K., Osborne, M. P., Boachie‐Adjei, K., & Feldman, S. M. (2008) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2008.06.007 · Cited by 69
Self-citationHeil, J., Breitkreuz, K., Golatta, M., Czink, E., Dahlkamp, J., Rom, J., Schütz, F., Blumenstein, M., Rauch, G., & Sohn, C. (2011) · Annals of Surgical Oncology · doi:10.1245/s10434-011-1947-1 · Cited by 68 · cited 1×
“There is also evidence that reexcision procedures negatively affect cosmetic outcomes.(17) Although cosmesis was not directly assessed in this study, the only factor potentially affected by MarginProbe use is volume of tissue excised.”
BackgroundMullenix, P. S., Cuadrado, D. G., Steele, S. R., Martin, M. J., See, C. S., Beitler, A. L., & Carter, P. L. (2004) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2004.01.003 · Cited by 63
Theodossiou, C., Schwarzenberger, P., EspinozaDelgado, I., Wynn, R., & Schapira, D. (1997) · Oncology Reports · doi:10.3892/or.4.6.1305 · Cited by 47
Lumpectomy Cavity Shaved Margins Do Not Impact Re-excision Rates in Breast Cancer Patients
Coopey, S. B., Buckley, J. M., Smith, B. L., Hughes, K. S., Gadd, M. A., & Specht, M. C. (2011) · Annals of Surgical Oncology · doi:10.1245/s10434-011-1909-7 · Cited by 45 · cited 1×
“However, a recent report from Massachusetts General Hospital showed no difference in reexcision rates in patients undergoing lumpectomy surgery, or lumpectomy plus selected or full-cavity shavings.(20) The total tissue volume removed was smaller in the patients who underwent select or complete cavity shavings, suggest…”
BackgroundVolume of Excision and Cosmesis with Routine Cavity Shave Margins Technique
Mook, J. A., Klein, R. L., Kobbermann, A., Unzeitig, A., Euhus, D., Peng, Y. S., Sarode, V. R., Moldrem, A. W., Leitch, A. M., Andrews, V., et al. (2011) · Annals of Surgical Oncology · doi:10.1245/s10434-011-1982-y · Cited by 45 · cited 2×
“This change in surgeons’ approach to the main lumpectomy specimen has also been reported in other studies.(19) At this point, full-cavity shaving has not been widely adopted.”
BackgroundResult
Cited by
Increased peri‐ductal collagen micro‐organization may contribute to raised mammographic density
McConnell, J. C., O’Connell, O. V., Brennan, K., Weiping, L., Howe, M., Joseph, L., Knight, D., O’Cualain, R., Lim, Y., Leek, A., et al. (2016) · Breast Cancer Research · doi:10.1186/s13058-015-0664-2 · Cited by 110
Metadata
- Authors
- Schnabel, F., Boolbol, S. K., Gittleman, M., Karni, T., Tafra, L., Feldman, S., Police, A., Friedman, N. B., Karlan, S., Holmes, D., Willey, S. C., Carmon, M., Fernandez, K., Akbari, S., Harness, J., Guerra, L., Frazier, T., Lane, K., Simmons, R. M., Estabrook, A., & Allweis, T.
- Venue
- Annals of Surgical Oncology
- Published
- 2014-03-05
- Volume
- 21
- Issue
- 5
- Pages
- 1589-1595
- ISSN
- 1068-9265 (ISSN-L)
- 1534-4681
- OpenAlex
- W2081676452
- Cited by
- 192
- References
- 18
- FWCI
- 9.81
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.